Skip to main content

Event Notification Report for October 26, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/25/2008 - 10/26/2008

EVENT NUMBERS
44601

Power Reactor
Event Number: 44601
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: RICKY LIDDELL
HQ OPS Officer: JASON KOZAL
Notification Date: 10/26/2008
Notification Time: 15:40 [ET]
Event Date: 10/26/2008
Event Time: 11:25 [CDT]
Last Update Date: 10/26/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
RICK DEESE (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 50 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM AND ISOLATION DUE TO TURBINE TRIP

"Actuation of RPS with reactor critical. Reactor Scram occurred at 11:25 am, 10/26/08 from approximately 50% CTP (core thermal power).

"A turbine/generator trip and automatic RPS reactor scram on TCV [turbine control valve] fast closure occurred. Exact cause of turbine/generator trip is not known at this time. All withdrawn control rods fully inserted to position 00.

"Reactor Water Level 3 (11.4") was reached which is an RPS Scram Setpoint and also a setpoint for Group 2 (RHR to Radwaste) and Group 3 (Shutdown Cooling Isolation). No valves isolated in these systems due to their being in their normally closed position. Lowest reactor water level reached was -3" Wide Range.

"Appropriate off normal event procedures were entered to mitigate the transient with all systems responding as designed. No loss of offsite or ESF power occurred. No ECCS initiation signals were reached, and no ECCS or DG initiation occurred. All safety systems performed as expected.

"MSIVs remained open and no SRV's lifted. Main Condenser and pressure control system remained in service. Currently, reactor water level is being maintained by the condensate system in normal level band and reactor pressure is being controlled to limit cooldown."

The licensee notified the NRC Resident Inspector.