General Information or Other
Event Number: 44600
Rep Org: SC DIV OF HEALTH & ENV CONTROL
Licensee: MACTEC ENGINEERING AND CONSULTING, INC.
Region: 1
City: COLUMBIA   State: SC
County:
License #: 568
Agreement: Y
Docket:
NRC Notified By: MELINDA BRADSHAW
HQ OPS Officer: VINCE KLCO
Notification Date: 10/24/2008
Notification Time: 15:34 [ET]
Event Date: 10/24/2008
Event Time: 00:00 [EDT]
Last Update Date: 10/29/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHRISTOPHER CAHILL (R1)
ANDREW MAUER (FSME)
ILTAB via e-mail
Event Text
AGREEMENT STATE REPORT - LOST MOISTURE DENSITY GAUGE

The following information was received via facsimile.

"The SC [South Carolina] Department of Health and Environmental Control was notified on Friday, October 24, 2008 at 12:05 p.m. that a Humboldt Model 5001 portable moisture density gauge had been lost, along with the licensee's company vehicle. [DELETED], Columbia Radiation Safety Officer, and [DELETED], Corporate RSO, notified the Department that a gauge technician had been in possession of the truck and portable gauge on Thursday, October 23. The technician apparently decided to go out for a 'night on the town' with the company vehicle/gauge and became highly intoxicated. As a result of this, per [DELETED] and [DELETED], the technician does not recall where the truck with the gauge was left. The technician called a fellow MACTEC employee this morning who then picked him up at his hotel. The keys to the MACTEC truck were in the possession of the errant technician so it has been assumed that the truck with the gauge secured in the truck bed is parked at a local nightspot. The technician has been questioned but can shed no light on where the truck is at this time. The licensee has called the police department to notify them of the situation. They have also called the city and county to rule out the possibility that the truck was towed overnight. No report of this vehicle being towed was on file. The licensee currently has four company trucks out looking for the lost vehicle and gauge.

"As more information is available, this notice will be updated. The licensee was advised that a written report detailing this event must be submitted to the Department within 30 days. The event is open and pending further investigation by the licensee and the Department. Updates will be made through the national NMED system."

Humboldt 5001 moisture density gauges nominally contain 10 mCi Cs-137 and 40 mCi Am:Be.

* * * UPDATE PROVEDED BY MELINDA BRADSHAW TO VINCE KLCO ON 10/29/08 AT 1152 * * *

The following was provided by the state via telephone:

MACTEC located both the lost portable moisture density gauge and the truck. Based on inspection, it was determined that the gauge is undamaged. The licensee will submit a report.

Notified R1DO (Cobey), FSME (Burgess) and ILTAB via e-mail.


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Power Reactor
Event Number: 44715
Facility: THREE MILE ISLAND
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: ADAM MILLER
HQ OPS Officer: KARL DIEDERICH
Notification Date: 12/12/2008
Notification Time: 08:25 [ET]
Event Date: 10/24/2008
Event Time: 13:18 [EST]
Last Update Date: 12/12/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
RONALD BELLAMY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
INADVERTENT ACTUATION OF ENGINEERED SAFEGUARDS SYSTEM FROM RELAY SENSING CIRCUIT

"This event is being reported via a telephone notification to the NRC Operations Center within 60 days after discovery of the event instead of submitting a written LER. In this case, the telephone report is not considered an LER. This report is being made under 10CFR 50.73 (a)(2)(iv)(A).

"During Engineered Safeguards Actuation System (ESAS) logic testing on October 24, 2008, an invalid actuation of the following heat removal systems occurred: 'B' train of the Decay Heat River Water System (DR), 'B' train of the Decay Heat Closed Cooling Water System (DCCW), and the 'B' train of the Nuclear Services River Water System (NR). There was no injection into the Reactor Coolant System. The invalid actuation occurred when the channel under test was taken to its tripped position. Since ESAS utilizes a 2 out of 3 logic for actuation, another actuation signal was present on one of the two channels not being tested, satisfying the actuation logic for the affected systems. The invalid actuation of these heat removal systems during testing on October 24, 2008 was due to oxidation on a silver-plated contact in one of the other two channels that was not being tested. This contact oxidation caused a higher input resistance to the timer relay, which resulted in an inadvertent actuation of the relay and its associated systems. The contact oxidation was caused as a result of using silver plated contacts in a low voltage application (approximately 12 VDC). During this invalid actuation, the heat removal systems were fully actuated. These heat removal systems functioned successfully and the operation of these systems did not have any adverse impact on plant operation.

"All of the silver-plated contacts in the affected circuits will be replaced with gold-plated contacts. The contacts are scheduled to be replaced by December 18, 2008.

"The NRC Resident Inspector has been notified."