Other Nuclear Material
Event Number: 44528
Rep Org: HALLIBURTON ENERGY SERVICES INC
Licensee: HALLIBURTON ENERGY SERVICES INC
Region: 4
City: HOUSTON   State: TX
County:
License #: OK-00502-03
Agreement: Y
Docket:
NRC Notified By: STEVE WOODS
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/30/2008
Notification Time: 16:09 [ET]
Event Date: 09/30/2008
Event Time: 00:00 [CDT]
Last Update Date: 12/05/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
RUSS BYWATER (R4)
MICHELE BURGESS (FSME)
Event Text
SOURCES LOST AT SEA WITH DRILLING RIG

"Please accept this as the preliminary notification of two devices which are currently being searched for as a result of the recent hurricane activity in the Gulf of Mexico. The devices are located on drilling rig ENSCO 74 however the rig has not been located. The rig owner is currently searching for the rig. The status was reported as follows: Ensco 74

"Legs are still on location leaning over. Legs appear to have broken off below barge.
"Rig has not been located yet.
"Since rig was in SMI 149 this block is close to deeper water and may be afloat or on bottom. [NOTE: this location is off the Louisiana coast]

"This rig has two densometer V32-0571 with source XA-417 and W25-599 with source DB-455 both are 10 mCi Cs-137 sources. I will advise when the rig is located either above or below water."

* * * UPDATE RECEIVED VIA E-MAIL FROM S. WOODS TO V. KLCO AT 1520 EST ON 12/05/08 * * *

"Ensco Offshore Company has abandoned the search efforts for their rig the Ensco 74 which the two below referenced devices were located. With that information, we do not believe that the devices will be recovered and should be considered lost due to the hurricane activity."

Notified R4DO (D. Proulx) and FSME (C. Einberg)

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Power Reactor
Event Number: 44530
Facility: VERMONT YANKEE
Region: 1     State: VT
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAN JEFFRIES
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/30/2008
Notification Time: 20:44 [ET]
Event Date: 09/30/2008
Event Time: 19:42 [EDT]
Last Update Date: 09/30/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JOHN WHITE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF PRIMARY OFFSITE NOTIFICATION CAPABILITY

"Loss of the Ames Hill NOAA transmitter [due to an] interrupted phone link between Albany and Ames Hill. Caused by a 'corruption' of the AT&T phone line between Albany and Ames Hill. This condition interrupted/interfered with the radio [frequency] link between WTSA radio station and the Ames Hill transmitter.

"Turn[ed] off corrupting phone lines interfering with radio frequency communications between Ames Hill transmitter and WTSA radio station. AT&T [was] contacted to repair phone line."

The normal configuration is the phone line is used for the primary signal and the radio link to WTSA radio station is for backup capability.

The licensee will be notifying the NRC Resident Inspector.

* * * UPDATE @ 2214 EDT ON 9/30/08 FROM JEFFRIES TO CROUCH * * *

The licensee reported that offsite notification capability was restored at 2105 EDT by disconnecting the corrupted phone line which automatically switched the radio signal to WTSA radio station as the primary signal for activation. The radio station performed a silent test to verify functionality.

The licensee will be notifying the NRC Resident Inspector of this update. Notified R1DO (White).


Fuel Cycle Facility
Event Number: 44532
Facility: NUCLEAR FUEL SERVICES INC.
Region: 2     State: TN
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: HEU CONVERSION & SCRAP RECOVERY
NAVAL REACTOR FUEL CYCLE
LEU SCRAP RECOVERY
NRC Notified By: RANDY SHACKELFORD
HQ OPS Officer: VINCE KLCO
Notification Date: 10/01/2008
Notification Time: 12:30 [ET]
Event Date: 09/30/2008
Event Time: 16:00 [EDT]
Last Update Date: 10/01/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
26.719 - FITNESS FOR DUTY
Person (Organization):
SCOTT SHAEFFER (R2)
SHEENA WHALEY (NMSS)
FUELS OUO VIA E-MAIL
Event Text
POSITIVE RANDOM FITNESS FOR DUTY TEST

A non-licensed employee supervisor had a confirmed positive for illegal drugs during a random fitness-for-duty test. The employee's access for the plant has been terminated. Contact the Headquarters Operations Officer for additional details.

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 44552
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: NORTHWEST INSPECTION
Region: 4
City: KENNEWICK   State: WA
County:
License #: IR065
Agreement: Y
Docket:
NRC Notified By: ARDEN SCROGGS
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 10/08/2008
Notification Time: 11:30 [ET]
Event Date: 09/30/2008
Event Time: 07:00 [PDT]
Last Update Date: 10/21/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
DALE POWERS (R4)
MARK DELLIGATTI (FSME)
Event Text
AGREEMENT STATE REPORT - RADIOGRAPHY SOURCE DISCONNECTED FROM CONTROL CABLE

Washington state submitted the following report via e-mail:

"A licensee reported to the Department of Health (DOH) that an industrial radiography (IR) source had become disconnected from the control cable that prevented the retrieval of the source back into its safe shielded position. The exposure device is a QSA Global Sigma 880 with a 97 Curie Iridium-192 source. The source disconnect occurred at 7:00 AM 9/30/08 at a construction site three miles northeast of Moses Lake, Washington. The President and Radiation Safety Officer (RSO) of the licensed IR company are on scene with 12 company employees to correct the situation. The radiographer had previously made several exposures on pipe welds earlier in the day before the disconnect occurred. The source remained at the end of the guide tube, in the collimator, when the radiographer tried to retract it into the device. The radiographer tried this several times. A large area at the construction site has been secured by barricades and the IR personnel are guarding the radiation area. At present, it appears that personnel have not received any elevated or unusual exposure as a result of the disconnect. The IR company is working with the Office of Radiation Protection and the radiography device manufacturer to develop a plan to retrieve the source. DOH staff were sent to the location to assure radiation safety procedures are followed and independent measurements are made."

Washington Report: WA080073

* * * UPDATE PROVIDED AT 1415 EDT ON 10/21/08 VIA EMAIL FROM ARDEN SCROGGS TO JEFF ROTTON * * *

The following information was obtained from the State of Washington via email:

"DOH staff went to the incident site at 1:30 p.m. on the day of the event. They assisted the IR company RSO establish the planned special exposure recovery plan. About 2:30 p.m. the construction-site safety officers were briefed on the recovery plan. Materials and equipment needed for the plan were assembled and at 3:35 they began the recovery operation. The plan included using a site crane and operator to extricate the camera, guide tube, collimator with source from the work scaffolding. The IR equipment was moved to a better location in an area away from the construction site. At 4:26 p.m. the camera and source were placed into a lead lined steel skiff-box and lifted to an area between a high dirt bank and tall concrete retaining wall. The new location was roped off and secured by the IR personnel. The actual recovery began at about 6:30. The IR drive cable was modified as the manufacturer recommended by filing two sides of the attachment fitting. Several attempts were made to hook onto the source pigtail. At around 9:30 the source was successfully pulled back into and locked in the camera. Surveys indicated the source was successfully placed into the shielded position. Pocket dosimeter readings for the four IR employees that were directly involved with the recovery indicated 10, 45, and 52 mRem. None of the construction workers received an exposure above background. The camera, with the source and associated equipment involved with the disconnect, was sent to the manufacturer for evaluation to determine why the equipment failed to operate as designed.

"On October 1, 2008, the DOH Radioactive Materials' supervisor and the IR program lead staff went to the site to follow-up with the investigation and to close the event. While on site, they addressed an assembly of 800 craft construction workers. Several asked questions about the incident and voiced their concerns for the potential exposure they may have received. DOH staff also talked directly to several individuals before and after the briefing. A large majority of the construction workers seemed to understand that their health and safety had not been affected as a result of the incident.

"[The State] has subsequently heard that the manufacturer (QSA Global) had determined that the pigtail connector had an engineering defect that allowed that connection to part from the drive cable causing the disconnect."

Notified FSME (Burgess) and R4DO (Deese)