Skip to main content

Event Notification Report for September 29, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/28/2008 - 09/29/2008

EVENT NUMBERS
44529445264452744535

General Information or Other
Event Number: 44529
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: HWA GEOSCIENCES
Region: 4
City: LYNNWOOD   State: WA
County:
License #: I0176
Agreement: Y
Docket:
NRC Notified By: ARDEN SCROGGS
HQ OPS Officer: HOWIE CROUCH
Notification Date: 09/30/2008
Notification Time: 16:50 [ET]
Event Date: 09/29/2008
Event Time: 00:00 [PDT]
Last Update Date: 10/23/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSS BYWATER (R4)
ANNA BRADFORD (FSME)
Event Text
WASHINGTON AGREEMENT STATE REPORT - DAMAGED TROXLER MOISTURE DENSITY GAUGE

The State of Washington provided the following information via e-mail:

"The licensee reported to the Washington State Department of Health (DOH) that a Troxler 3440 nuclear density gauge, serial number 28433, with 8 mCi of Cs-137 and 40 mCi of Am-241/Be, was struck by a truck at a landfill site at about 12:45 p.m. on 9/29/08. The gauge was struck while the operator was taking measurements with the source rod extended into the soil. It was reported that a truck tried to skim by the operator and gauge, narrowly missing the operator and hitting the gauge. The truck caught the gauge handle breaking it and the guide rod from the gauge. The source rod and the rest of the gauge remained intact and in place. The licensee field engineer and lead gauge operator went to the scene to assist with the incident. Since the handle was broken from the gauge, the source rod was placed back into the gauge by turning the gauge on its side and striking the bottom of source rod with a mallet. This action caused the source rod to move completely out of the top of the gauge. The lead individual put the source rod into a bucket and found a max reading of 20 mR/hr. The lead [operator] returned the source rod back into the shielded position in the gauge and secured [it] in place with duct tape. Additional wraps of duct tape were made around the top and bottom of the gauge to keep the source rod from coming out again. A reading of 2.4 mR/hr was found on contact with the gauge with the licensees' TroxAlert. Additional readings were taken on the bucket and the testing site indicating background readings. The gauge was placed back into the transport case and taken to the licensed storage location prior to determining its final disposition. DOH staff will visit the licensee to make confirmatory measurements and start an investigation."

Washington Report Number: WA080072

* * * UPDATE PROVIDED AT 1717 EDT ON 10/23/08 FROM STATE (CLARK) TO JEFF ROTTON * * *

The following information was provided by the State of Washington via email:

"Two DOH staff visited the licensed storage location and investigated the incident on 09/30/08. After interviewing the operator, the field engineer and the RSO, the staff inspected the damaged gauge. The gauge was removed from its transport box and placed on a table for inspection. The gauge had been duct taped with the source rod in position to keep the shutter closed. The majority of the gauge was intact; a small piece of the T handle had been broken off and was separate from the gauge. DOH staff surveyed the gauge with several instruments. An Eberline RO-2 (serial number 2587, cal date 05-07-08) reported a surface contact reading of 6 mR/hr. A Ludlum 2363 neutron/gamma instrument reported a surface contact rate of 5 mRem/hr. The gauge was then turned over and the orifice was surveyed. The Eberline reported 20-22 mR/hr, which is higher than normal, and the Ludlum reported 13 mRem/hr. The shutter appeared to be only 3/4 closed. The T handle was manipulated to return the shutter to a completely closed position and duct taped into place. The orifice of the gauge than read 4 mR/hr with the Eberline. DOH staff than took two swabs, one of the sources (with rod extended) and one in the transport case. Both swabs were taken out of the area and surveyed with RADALERT Inspector SN 21089. The swabs did not indicate any contamination so it appears the cesium source was not leaking. The gauge was then carefully placed back into its transit box and the box was surveyed at a distance of one meter to determine the transport index (TI). A TI of 0.6 was marked on the label. The gauge was shipped back to Troxler for repair and leak testing."

Notified R4DO (Deese) and FSME (Mauer)


Power Reactor
Event Number: 44526
Facility: OYSTER CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: THOMAS BUSK
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/29/2008
Notification Time: 14:45 [ET]
Event Date: 09/29/2008
Event Time: 09:18 [EDT]
Last Update Date: 09/29/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JOHN WHITE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 98 Power Operation 98 Power Operation
Event Text
LOSS OF INTERNAL PHONE SYSTEMS

"A loss of internal phone systems was experienced at the station on 9/29/08 at 0918. This loss included the ENS phone line. Compensatory measures using cellular phones were established with the NRC. The phone outage did not affect the emergency plan state and local notification system. This event had no adverse affect on plant operations. Intermittent phone outages are expected until the issue is resolved. Maintenance is ongoing to investigate and correct the cause."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 44527
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: JEFF SIMPSON
HQ OPS Officer: HOWIE CROUCH
Notification Date: 09/29/2008
Notification Time: 15:15 [ET]
Event Date: 09/29/2008
Event Time: 10:09 [CDT]
Last Update Date: 09/29/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
STEVE ORTH (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
3 N Y 94 Power Operation 94 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO DISCHARGE OF OIL INTO NAVIGABLE WATERS

"Notified by the Operations Incident Commander at 1009 CDT that a sheen of oil is visible on the Kankakee River north of the Goose Lake pumping station. It is estimated that 1 gallon may have been discharged to the Kankakee River.

"The leak was from a temporary diesel driven pump that was in place due to the recent flooding in the area. The pump has been secured and has been moved from the area.

"Notified the Illinois Emergency [Management] Agency (IEMA) of the fuel oil spill to the Kankakee River. IEMA incident report number H20081478. Reported to Agent [DELETED] at 1023 CDT.

"Notified the National Emergency Response Center of the oil spill to the Kankakee River. Incident report #885611. Reported to [DELETED] at 1055 CDT."

The licensee made the reports based on the requirements of the Federal Water Pollution Act, Section 311(b)(5), 40 CFR 110.5 and 40 CFR 112.4.

The licensee has notified the NRC Resident Inspector.


General Information or Other
Event Number: 44535
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: METCO
Region: 4
City: HOUSTON   State: TX
County:
License #: L-03018
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: BILL HUFFMAN
Notification Date: 10/03/2008
Notification Time: 10:58 [ET]
Event Date: 09/29/2008
Event Time: 13:00 [CDT]
Last Update Date: 10/21/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSS BYWATER (R4)
ANNA BRADFORD (FSME)
Event Text
AGREEMENT STATE REPORT - POTENTIAL OVEREXPOSURE TO EXTREMITIES

A radiographer working for METCO was performing radiography operations at CB & I Fabricators in Houston TX. He was moving the radiography camera (a SPEC 150 with a 85 curie Ir-192 source) from one location to another. He removed the nipple off the front of the camera to test the guide tube and his dosimetry started alarming. He observed that the source had come out of the camera about 1/2 inch. At the same time, he inadvertently dropped the camera plug. He picked up the plug and unsuccessfully made two attempts to push the source back in with the plug. He then left the front of the camera and went around and turned the crank and got the source back into the shielded position and then inserted the plug. He then notified appropriate personnel.

METCO sent his dosimetry off and the results came back with a whole body exposure of 946 millirem on October 1. The RSO discussed the details of the event with the radiographer and reenacted the event to attempt to estimate the radiographer's hand exposure because to the close proximity of the source to the hand during the event. Based on the time and distance of the source to the hand, it was estimated that the exposure to the radiographer's right hand may be somewhere between 66 and 282 rem. METCO has called in a consultant to get a more accurate assessment of the exposure to the hand.

The radiographer's work for the rest of the year has been suspended. His hand does not exhibit any eurythemia. No information is available on whether blood work or medical study will be obtained.

Texas will wait for the licensee's final report before it completes and independent investigation of the event.

Texas Report I-8569

* * * UPDATE PROVIDED AT 1210 EDT ON 10/21/08 FROM ART TUCKER VIA EMAIL TO JEFF ROTTON * * *

The following information was received from the State of Texas via email:

"The licensee provided the final dose estimate for the individual involved in this event. The licensee used conservative times established in several reenactments of the event, NCRP publications, and the source manufacturers information to calculate the dose estimate. The estimate to the individual's right hand is 233.71 Rem SDE. The State of Texas calculated the dose to be 235.65 Rem SDE. This individual's TEDE dose was measured at 2.762 Rem for the 2008 calendar year.

Notified FSME (Burgess) and R4DO (Deese).