Event Notification Report for September 17, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/16/2008 - 09/17/2008
EVENT NUMBERS
4451044498444994451844578
General Information or Other
Event Number: 44510
Rep Org: NE DIV OF RADIOACTIVE MATERIALS
Licensee: TYCO HEALTH CARE GROUP
Region: 4
City: NORFOLK State: NE
County:
License #: 07-02-01
Agreement: Y
Docket:
NRC Notified By: BRYAN MILLER
HQ OPS Officer: JOHN KNOKE
Licensee: TYCO HEALTH CARE GROUP
Region: 4
City: NORFOLK State: NE
County:
License #: 07-02-01
Agreement: Y
Docket:
NRC Notified By: BRYAN MILLER
HQ OPS Officer: JOHN KNOKE
Notification Date: 09/22/2008
Notification Time: 14:41 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [CDT]
Last Update Date: 09/22/2008
Notification Time: 14:41 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [CDT]
Last Update Date: 09/22/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM JONES (R4)
MICHELE BURGESS (FSME)
WILLIAM JONES (R4)
MICHELE BURGESS (FSME)
AGREEMENT STATE REPORT - SMOKE DETECTOR FAILED TO OPERATE PROPERLY
Licensee was testing the smoke detector outside the vault that houses the irradiator. The detector failed to operate. The irradiator (1645 kCi of Co-60) was not in operation at the time of the test. This is being reported under 10 CFR 30.50 (b)(2).
NE Report # NE080009
Licensee was testing the smoke detector outside the vault that houses the irradiator. The detector failed to operate. The irradiator (1645 kCi of Co-60) was not in operation at the time of the test. This is being reported under 10 CFR 30.50 (b)(2).
NE Report # NE080009
Power Reactor
Event Number: 44498
Facility: MONTICELLO
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: RANDY SANDS
HQ OPS Officer: BILL HUFFMAN
Region: 3 State: MN
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: RANDY SANDS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 09/17/2008
Notification Time: 11:40 [ET]
Event Date: 09/17/2008
Event Time: 10:17 [CDT]
Last Update Date: 09/21/2008
Notification Time: 11:40 [ET]
Event Date: 09/17/2008
Event Time: 10:17 [CDT]
Last Update Date: 09/21/2008
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
ANNE MARIE STONE (R3)
JOHN THORP (NRR)
ERIC LEEDS (ET)
MARK SATORIOUS (R3)
BRIAN McDERMOTT (IRD)
ANNE MARIE STONE (R3)
JOHN THORP (NRR)
ERIC LEEDS (ET)
MARK SATORIOUS (R3)
BRIAN McDERMOTT (IRD)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
UNUSUAL EVENT DUE TO LOSS OF SHUTDOWN COOLING
Monticello lost the 1R offsite power transformer due to an industrial accident that grounded the bus and resulted in a fatality of an employee onsite. At the time of this event, the 2R offsite transformer was already out of service due to a previous event (see EN #44484). This effectively resulted in a loss of all normal offsite power. The 1AR safety related offsite power source remained available and the safety related buses are energized and diesels are available. However, shutdown cooling was lost during the event due to a Group 2 isolation and cannot be restored. The shutdown cooling suction isolation valves #2020 and #2030 have power but until the Group 2 logic can be reset the valves cannot be reopened. The licensee needs to repower the RPS bus to reset the logic. Based on the uncertainty in reestablishing shutdown cooling an Unusual Event was declared based on Emergency Director judgment (EAL HU5.1). Current reactor coolant temperature is approximately 110 degrees with a heatup rate of about 20 degrees an hour.
State and local authorities and the NRC resident inspector have been notified. The licensee will likely be making a press release.
* * * UPDATE AT 1417 EDT ON 09/17/08 FROM CORY JASKOWIAK TO S. SANDIN * * *
"On Wednesday, September 17, 2008 Monticello Nuclear Generating Plant (MNGP) experienced a loss of power to the station transformer resulting in a valid actuation of the following systems: Reactor Protection System (with the reactor shutdown), Containment Isolation, and Emergency Diesel Generators.
"The cause of the loss of power was due to contact of a 115kV transmission line by a manlift. A vendor employee was electrocuted. On-site Medical Emergency Response personnel responded until the individual was transported to North Memorial Medical Center. The individual was pronounced dead at North Memorial Medical Center.
"Notifications of offsite agencies and a media press release are in progress. 'This notification is being made in accordance 10CFR50.72(b)(2)(xi) and 10CFR50.72(b)(3)(iv)(A).'
"Licensee notified the NRC Resident Inspector." Notified R3IRC (Garza)
* * * UPDATE AT 1715 EDT ON 09/17/08 FROM R. BAUMER TO S. SANDIN * * *
"This is a follow-up to Event notification #44498. The station has completed notifications to off-site agencies and to the media. The station continues to troubleshoot and restore plant equipment and respond to media inquiries.
"NUE update - As of 1113 CDT shutdown cooling was restored." Notified R3 IRC.
* * * UPDATE AT 1220 EDT ON 9/21/08 FROM DAN NORHEIM TO JOHN KNOKE * * *
"Monticello Nuclear Generating Plant exited their Notification of Unusual Event at 1100 CDT on 9/21/08. The exit criteria is supported on the following information: (1) This event did not result in the loss or potential loss of a fission product barrier and did not change the status of the current fuel condition. All three fission barriers are intact and were maintained throughout the event. (2) There were no radiation releases as a result of the event. (3) Restoration of plant loads including shutdown cooling onto a normal offsite power source (the 1R transformer) has been completed. (4) The 1R transformer offsite power source was recovered and is being protected. Protection of the 1R transformer will continue until availability of the other offsite power source supplied from the 2RS/2R transformers has been restored. (5) Shutdown cooling is in service. (6) The site organization challenges in response to the injury event and loss of decay heat removal are no longer present."
The licensee has notified the NRC Resident Inspector, as well as state and local agencies. A media release will be issued. Notified R3DO (Stone), NRR EO (Galloway), IRD MOC (Clark), OPA (Burnell), DHS (S. Moore), and FEMA (D. Fuller).
Monticello lost the 1R offsite power transformer due to an industrial accident that grounded the bus and resulted in a fatality of an employee onsite. At the time of this event, the 2R offsite transformer was already out of service due to a previous event (see EN #44484). This effectively resulted in a loss of all normal offsite power. The 1AR safety related offsite power source remained available and the safety related buses are energized and diesels are available. However, shutdown cooling was lost during the event due to a Group 2 isolation and cannot be restored. The shutdown cooling suction isolation valves #2020 and #2030 have power but until the Group 2 logic can be reset the valves cannot be reopened. The licensee needs to repower the RPS bus to reset the logic. Based on the uncertainty in reestablishing shutdown cooling an Unusual Event was declared based on Emergency Director judgment (EAL HU5.1). Current reactor coolant temperature is approximately 110 degrees with a heatup rate of about 20 degrees an hour.
State and local authorities and the NRC resident inspector have been notified. The licensee will likely be making a press release.
* * * UPDATE AT 1417 EDT ON 09/17/08 FROM CORY JASKOWIAK TO S. SANDIN * * *
"On Wednesday, September 17, 2008 Monticello Nuclear Generating Plant (MNGP) experienced a loss of power to the station transformer resulting in a valid actuation of the following systems: Reactor Protection System (with the reactor shutdown), Containment Isolation, and Emergency Diesel Generators.
"The cause of the loss of power was due to contact of a 115kV transmission line by a manlift. A vendor employee was electrocuted. On-site Medical Emergency Response personnel responded until the individual was transported to North Memorial Medical Center. The individual was pronounced dead at North Memorial Medical Center.
"Notifications of offsite agencies and a media press release are in progress. 'This notification is being made in accordance 10CFR50.72(b)(2)(xi) and 10CFR50.72(b)(3)(iv)(A).'
"Licensee notified the NRC Resident Inspector." Notified R3IRC (Garza)
* * * UPDATE AT 1715 EDT ON 09/17/08 FROM R. BAUMER TO S. SANDIN * * *
"This is a follow-up to Event notification #44498. The station has completed notifications to off-site agencies and to the media. The station continues to troubleshoot and restore plant equipment and respond to media inquiries.
"NUE update - As of 1113 CDT shutdown cooling was restored." Notified R3 IRC.
* * * UPDATE AT 1220 EDT ON 9/21/08 FROM DAN NORHEIM TO JOHN KNOKE * * *
"Monticello Nuclear Generating Plant exited their Notification of Unusual Event at 1100 CDT on 9/21/08. The exit criteria is supported on the following information: (1) This event did not result in the loss or potential loss of a fission product barrier and did not change the status of the current fuel condition. All three fission barriers are intact and were maintained throughout the event. (2) There were no radiation releases as a result of the event. (3) Restoration of plant loads including shutdown cooling onto a normal offsite power source (the 1R transformer) has been completed. (4) The 1R transformer offsite power source was recovered and is being protected. Protection of the 1R transformer will continue until availability of the other offsite power source supplied from the 2RS/2R transformers has been restored. (5) Shutdown cooling is in service. (6) The site organization challenges in response to the injury event and loss of decay heat removal are no longer present."
The licensee has notified the NRC Resident Inspector, as well as state and local agencies. A media release will be issued. Notified R3DO (Stone), NRR EO (Galloway), IRD MOC (Clark), OPA (Burnell), DHS (S. Moore), and FEMA (D. Fuller).
General Information or Other
Event Number: 44499
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: UNION CARBIDE
Region: 4
City: SEADRIFT State: TX
County:
License #: 00051
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: DAN LIVERMORE
Licensee: UNION CARBIDE
Region: 4
City: SEADRIFT State: TX
County:
License #: 00051
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: DAN LIVERMORE
Notification Date: 09/17/2008
Notification Time: 13:52 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [CDT]
Last Update Date: 09/17/2008
Notification Time: 13:52 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [CDT]
Last Update Date: 09/17/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GREG PICK (R4)
CHRIS EINBERG
GREG PICK (R4)
CHRIS EINBERG
AGREEMENT STATE REPORT - BROKEN GAUGE
"On September 17, 2008 the licensee reported that a[n] Ohmart/Vega (OV) model SH-F1 has a sheared bolt on the shutter handle which prevents it from closing. This device (S/N 1297GK) contains 20mCi of Cs-137 in a model OV A-2100 sealed source capsule. The manufacturer has been notified and will see to the proper repair or replacement of the gauge. No public exposures are likely to approach regulatory limits and the vessel has been posted to prevent entry."
"On September 17, 2008 the licensee reported that a[n] Ohmart/Vega (OV) model SH-F1 has a sheared bolt on the shutter handle which prevents it from closing. This device (S/N 1297GK) contains 20mCi of Cs-137 in a model OV A-2100 sealed source capsule. The manufacturer has been notified and will see to the proper repair or replacement of the gauge. No public exposures are likely to approach regulatory limits and the vessel has been posted to prevent entry."
General Information or Other
Event Number: 44518
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: GEORGIA-PACIFIC CONSUMER PRODUCTS
Region: 4
City: ZACHARY State: LA
County:
License #: LA-2162-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: GEORGIA-PACIFIC CONSUMER PRODUCTS
Region: 4
City: ZACHARY State: LA
County:
License #: LA-2162-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/25/2008
Notification Time: 16:07 [ET]
Event Date: 09/17/2008
Event Time: 03:20 [CDT]
Last Update Date: 09/25/2008
Notification Time: 16:07 [ET]
Event Date: 09/17/2008
Event Time: 03:20 [CDT]
Last Update Date: 09/25/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
LINDA SMITH (R4)
REBECCA TADESSE (FSME)
LINDA SMITH (R4)
REBECCA TADESSE (FSME)
AGREEMENT STATE REPORT - SHIELDING PLATE FELL OFF KR-85 MEASURING DEVICE
"On September 17, 2008, at 3:20 a.m. the Radiation Safety Officer for Georgia-Pacific called the answering service for radiation incidents after hours. He stated that the screws on a Honeywell Measurex unit, model 4201 had backed out and a shielding plate fell off leaving a 1 Ci Kr-85 source exposed. He stated that the operator had roped off the area around the paper machine to prevent access and exposure. The operator described the time and distance to the source and it was determined that any exposure would have been minimal. Honeywell International, license LA-10814-L01 was contacted for servicing and packaging of the unit. The service tech was to be at the facility September 17, 2008 around 4:00 p.m. because he was traveling from out of state. The facility will follow up with a report and additional information concerning this incident."
Louisiana Incident: LA0800019
"On September 17, 2008, at 3:20 a.m. the Radiation Safety Officer for Georgia-Pacific called the answering service for radiation incidents after hours. He stated that the screws on a Honeywell Measurex unit, model 4201 had backed out and a shielding plate fell off leaving a 1 Ci Kr-85 source exposed. He stated that the operator had roped off the area around the paper machine to prevent access and exposure. The operator described the time and distance to the source and it was determined that any exposure would have been minimal. Honeywell International, license LA-10814-L01 was contacted for servicing and packaging of the unit. The service tech was to be at the facility September 17, 2008 around 4:00 p.m. because he was traveling from out of state. The facility will follow up with a report and additional information concerning this incident."
Louisiana Incident: LA0800019
General Information or Other
Event Number: 44578
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: ST. VINCENT'S HOSPITAL
Region: 1
City: JACKSONVILLE State: FL
County:
License #: FL Lic 14-6
Agreement: Y
Docket:
NRC Notified By: DAVID FERGUSON
HQ OPS Officer: RYAN ALEXANDER
Licensee: ST. VINCENT'S HOSPITAL
Region: 1
City: JACKSONVILLE State: FL
County:
License #: FL Lic 14-6
Agreement: Y
Docket:
NRC Notified By: DAVID FERGUSON
HQ OPS Officer: RYAN ALEXANDER
Notification Date: 10/17/2008
Notification Time: 17:48 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [EDT]
Last Update Date: 10/17/2008
Notification Time: 17:48 [ET]
Event Date: 09/17/2008
Event Time: 00:00 [EDT]
Last Update Date: 10/17/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
TODD JACKSON (R1)
BILL VONTILL (FSME)
TODD JACKSON (R1)
BILL VONTILL (FSME)
AGREEMENT STATE REPORT - DOSE TO UNINTENDED TISSUES
The State of Florida was notified on 10/17/2008 by the licensee's Medical Physicist regarding a dose of 3400 cGy (3400 rad) administered to unintended tissues during several breast cancer therapy treatments over the period of September 10 - 17, 2008. The apparent unintended dose was identified on 10/16/2008, when the patient reported to the licensee symptoms of erythma (skin reddening) to the breast not intended to be treated.
Specifically, the patient was being treated for breast cancer with an Ir-192 High Dose Rate (HDR) Afterloader unit (source strength, manufacturer, and model unknown at the time of this report). When the erythema was reported by the patient, the Medical Physicist reviewed the records and determined that the HDR Afterloader was mis-programmed such that the source stopped 10 centimeters short of the intended tumor bed in the right breast. As a result, the entire dose intended for the tumor bed was administered to the left breast that was not intended to be treated.
The State of Florida did not currently have information regarding any potential long term effects for the patient due to this event. The State of Florida will dispatch an inspector to the facility early next week to follow-up on this event. A written report of this event will be provide by the State at that time.
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The State of Florida was notified on 10/17/2008 by the licensee's Medical Physicist regarding a dose of 3400 cGy (3400 rad) administered to unintended tissues during several breast cancer therapy treatments over the period of September 10 - 17, 2008. The apparent unintended dose was identified on 10/16/2008, when the patient reported to the licensee symptoms of erythma (skin reddening) to the breast not intended to be treated.
Specifically, the patient was being treated for breast cancer with an Ir-192 High Dose Rate (HDR) Afterloader unit (source strength, manufacturer, and model unknown at the time of this report). When the erythema was reported by the patient, the Medical Physicist reviewed the records and determined that the HDR Afterloader was mis-programmed such that the source stopped 10 centimeters short of the intended tumor bed in the right breast. As a result, the entire dose intended for the tumor bed was administered to the left breast that was not intended to be treated.
The State of Florida did not currently have information regarding any potential long term effects for the patient due to this event. The State of Florida will dispatch an inspector to the facility early next week to follow-up on this event. A written report of this event will be provide by the State at that time.
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.