Event Notification Report for August 07, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/06/2008 - 08/07/2008
EVENT NUMBERS
44397443994438844390443924439344394
General Information or Other
Event Number: 44397
Rep Org: OHIO BUREAU OF RADIATION PROTECTION
Licensee: CLEVELAND CLINIC FOUNDATION
Region: 3
City: CLEVELAND State: OH
County:
License #: 02110-18-0013
Agreement: Y
Docket:
NRC Notified By: MARK LIGHT
HQ OPS Officer: BILL HUFFMAN
Licensee: CLEVELAND CLINIC FOUNDATION
Region: 3
City: CLEVELAND State: OH
County:
License #: 02110-18-0013
Agreement: Y
Docket:
NRC Notified By: MARK LIGHT
HQ OPS Officer: BILL HUFFMAN
Notification Date: 08/08/2008
Notification Time: 11:29 [ET]
Event Date: 08/07/2008
Event Time: 14:00 [EDT]
Last Update Date: 08/08/2008
Notification Time: 11:29 [ET]
Event Date: 08/07/2008
Event Time: 14:00 [EDT]
Last Update Date: 08/08/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
DAVID HILLS (R3)
DUNCAN WHITE (FSME)
DAVID HILLS (R3)
DUNCAN WHITE (FSME)
AGREEMENT STATE REPORT - UNDEREXPOSURE DURING HDR MEDICAL TREATMENT DUE TO EQUIPMENT MALFUNCTION
The State received notification of a possible medical event due to an equipment malfunction. The licensee was treating a patient for rectal cancer using an HDR Nucleotron Micro Select Model 105.999 Serial 31776. The prescribed treatment consisted of the administration of 29 catheter doses of Iridium-192. During the 12th catheter dose, an equipment malfunction caused a failure of the administered treatment. The failure mode was Code 200 - "No radiation detected." The failure mode caused the unit to stop treatment by not proceeding to the next catheter. Nucleotron immediately contacted. A service technician is expected to arrive on 8/8/08 for repair of the device. Once the HDR unit is repaired, the treatment plan and written directive will be modified and treatment of the patient resumed. Patient and physician have been advised of the treatment interruption and no adverse impact is expected.
The State of Ohio plans to send an inspector to the facility on 8/11/08.
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
The State received notification of a possible medical event due to an equipment malfunction. The licensee was treating a patient for rectal cancer using an HDR Nucleotron Micro Select Model 105.999 Serial 31776. The prescribed treatment consisted of the administration of 29 catheter doses of Iridium-192. During the 12th catheter dose, an equipment malfunction caused a failure of the administered treatment. The failure mode was Code 200 - "No radiation detected." The failure mode caused the unit to stop treatment by not proceeding to the next catheter. Nucleotron immediately contacted. A service technician is expected to arrive on 8/8/08 for repair of the device. Once the HDR unit is repaired, the treatment plan and written directive will be modified and treatment of the patient resumed. Patient and physician have been advised of the treatment interruption and no adverse impact is expected.
The State of Ohio plans to send an inspector to the facility on 8/11/08.
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
Power Reactor
Event Number: 44399
Facility: TURKEY POINT
Region: 2 State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: MICHEAL COEN
HQ OPS Officer: JASON KOZAL
Region: 2 State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: MICHEAL COEN
HQ OPS Officer: JASON KOZAL
Notification Date: 08/08/2008
Notification Time: 16:01 [ET]
Event Date: 08/07/2008
Event Time: 12:30 [EDT]
Last Update Date: 08/08/2008
Notification Time: 16:01 [ET]
Event Date: 08/07/2008
Event Time: 12:30 [EDT]
Last Update Date: 08/08/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
GEORGE HOPPER (R2)
GEORGE HOPPER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 4 | N | Y | 100 | Power Operation | 100 | Power Operation |
DEGRADED PRINCIPAL SAFETY BARRIER
"This is a late non-emergency notification to the NRC Operations Center in accordance with 10 CFR 50.72(b)(3)(ii)(A) due to the degradation of a principal safety barrier.
"A flaw in a weld in a 3/4 inch test connection off the seal water injection line for the 4B reactor coolant pump was identified at approximately 1230 during a containment entry on August 7, 2008. The flaw is leaking at the rate of approximately 0.14 gpm (current total), it [the leak] is isolable, and the leakage is currently considered as unidentified leakage from the reactor coolant system. The Technical Specification limit for unidentified leakage is 1.0 gpm.
"Currently, the leak is being monitored while repair options are evaluated."
The licensee notified the NRC Resident Inspector.
"This is a late non-emergency notification to the NRC Operations Center in accordance with 10 CFR 50.72(b)(3)(ii)(A) due to the degradation of a principal safety barrier.
"A flaw in a weld in a 3/4 inch test connection off the seal water injection line for the 4B reactor coolant pump was identified at approximately 1230 during a containment entry on August 7, 2008. The flaw is leaking at the rate of approximately 0.14 gpm (current total), it [the leak] is isolable, and the leakage is currently considered as unidentified leakage from the reactor coolant system. The Technical Specification limit for unidentified leakage is 1.0 gpm.
"Currently, the leak is being monitored while repair options are evaluated."
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 44388
Facility: WATTS BAR
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DOUGLAS HOLT
HQ OPS Officer: PETE SNYDER
Region: 2 State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DOUGLAS HOLT
HQ OPS Officer: PETE SNYDER
Notification Date: 08/07/2008
Notification Time: 04:12 [ET]
Event Date: 08/07/2008
Event Time: 02:28 [EDT]
Last Update Date: 08/07/2008
Notification Time: 04:12 [ET]
Event Date: 08/07/2008
Event Time: 02:28 [EDT]
Last Update Date: 08/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
GEORGE HOPPER (R2)
GEORGE HOPPER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 50 | Power Operation | 0 | Hot Standby |
TRIP FROM 50% POWER FOLLOWING LOW PRESSURE HEATER STRING ISOLATION
"On August 7, 2008 at 0228 EDT, TVA was reducing reactor power in preparation for a planned reactor shut down. While at approximately 50% power, the feedwater system isolated due to high levels in the low pressure heater strings. Based on the condition stated, the reactor was manually scrammed. All systems functioned as designed in response to the scram. The plant is currently being maintained in Mode 3 Hot Standby condition."
All control rods fully inserted on the manual trip. Decay heat is being removed via auxiliary feedwater to the steam generators steaming to the main condenser. Offsite power is supplying safety buses and emergency diesel generators are available if required.
The licensee notified the NRC Resident Inspector.
"On August 7, 2008 at 0228 EDT, TVA was reducing reactor power in preparation for a planned reactor shut down. While at approximately 50% power, the feedwater system isolated due to high levels in the low pressure heater strings. Based on the condition stated, the reactor was manually scrammed. All systems functioned as designed in response to the scram. The plant is currently being maintained in Mode 3 Hot Standby condition."
All control rods fully inserted on the manual trip. Decay heat is being removed via auxiliary feedwater to the steam generators steaming to the main condenser. Offsite power is supplying safety buses and emergency diesel generators are available if required.
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 44390
Facility: COOK
Region: 3 State: MI
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BRAD LEWIS
HQ OPS Officer: JOHN KNOKE
Region: 3 State: MI
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BRAD LEWIS
HQ OPS Officer: JOHN KNOKE
Notification Date: 08/07/2008
Notification Time: 12:13 [ET]
Event Date: 08/07/2008
Event Time: 12:15 [EDT]
Last Update Date: 08/07/2008
Notification Time: 12:13 [ET]
Event Date: 08/07/2008
Event Time: 12:15 [EDT]
Last Update Date: 08/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
DAVID HILLS (R3)
DAVID HILLS (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
UNAVAILABILITY OF TECHNICAL SUPPORT CENTER
"At 1215 EDT on Thursday, August 7, 2008, the Cook Nuclear Plant (CNP) Technical Support Center (TSC) ventilation system charcoal filter was removed from service for scheduled preventive maintenance on one of the TSC air conditioning systems. The charcoal bed filtration system is also out of service in support of the maintenance on the air conditioning system.
"Under certain accident conditions the TSC may become unavailable due to the inability of the filtration system to maintain a habitable atmosphere. Compensatory measures exist to relocate TSC personnel to the unaffected unit's control room if necessary based upon results of procedurally required monitoring of TSC radiological conditions. Air conditioning system maintenance is scheduled to complete at 1515 EDT on Thursday, August 7, 2008.
"This notification is being made in accordance with 10 CFR 50.72 (b)(3)(xiii) due to the loss an emergency
response facility. The licensee has notified the NRC Resident Inspector."
* * * UPDATE FROM BRAD LEWIS TO JOHN KNOKE AT 1657 EDT ON 08/07/08 * * *
"The TSC air conditioning system was returned to functional status at 16:25 on Thursday, August 7, 2008.
"This follow up notification is being made to provide closure from the initial notification under 10 CFR 50.72 (b)(3)(xiii) due to the loss an emergency response facility."
The licensee has notified the NRC Resident Inspector. Notified R3DO (David Hills)
"At 1215 EDT on Thursday, August 7, 2008, the Cook Nuclear Plant (CNP) Technical Support Center (TSC) ventilation system charcoal filter was removed from service for scheduled preventive maintenance on one of the TSC air conditioning systems. The charcoal bed filtration system is also out of service in support of the maintenance on the air conditioning system.
"Under certain accident conditions the TSC may become unavailable due to the inability of the filtration system to maintain a habitable atmosphere. Compensatory measures exist to relocate TSC personnel to the unaffected unit's control room if necessary based upon results of procedurally required monitoring of TSC radiological conditions. Air conditioning system maintenance is scheduled to complete at 1515 EDT on Thursday, August 7, 2008.
"This notification is being made in accordance with 10 CFR 50.72 (b)(3)(xiii) due to the loss an emergency
response facility. The licensee has notified the NRC Resident Inspector."
* * * UPDATE FROM BRAD LEWIS TO JOHN KNOKE AT 1657 EDT ON 08/07/08 * * *
"The TSC air conditioning system was returned to functional status at 16:25 on Thursday, August 7, 2008.
"This follow up notification is being made to provide closure from the initial notification under 10 CFR 50.72 (b)(3)(xiii) due to the loss an emergency response facility."
The licensee has notified the NRC Resident Inspector. Notified R3DO (David Hills)
Power Reactor
Event Number: 44392
Facility: BROWNS FERRY
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: MICHAEL HUNTER
HQ OPS Officer: JOHN KNOKE
Region: 2 State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: MICHAEL HUNTER
HQ OPS Officer: JOHN KNOKE
Notification Date: 08/07/2008
Notification Time: 16:46 [ET]
Event Date: 08/07/2008
Event Time: 07:00 [CDT]
Last Update Date: 08/07/2008
Notification Time: 16:46 [ET]
Event Date: 08/07/2008
Event Time: 07:00 [CDT]
Last Update Date: 08/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GEORGE HOPPER (R2)
GEORGE HOPPER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 50 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 50 | Power Operation |
| 3 | N | Y | 100 | Power Operation | 50 | Power Operation |
POWER REDUCED TO COMPLY WITH RIVER WATER QUALITY STANDARDS
"On August 7, 2008 Browns Ferry Nuclear Plant Units 1, 2, & 3 reduced reactor power to 50 percent to ensure continued thermal compliance with water quality standards as regulated by the Alabama Department of Environmental Management. This was caused by an unexpected failure of cooling tower components, rendering the cooling towers unavailable. Plant Operations continues to monitor river conditions and may take further actions as required to maintain compliance.
"There were no safety systems challenged during the power reductions.
"This is an informational report based on media interest. TVA does not expect to make an official news release. The NRC Resident Inspector was notified."
"On August 7, 2008 Browns Ferry Nuclear Plant Units 1, 2, & 3 reduced reactor power to 50 percent to ensure continued thermal compliance with water quality standards as regulated by the Alabama Department of Environmental Management. This was caused by an unexpected failure of cooling tower components, rendering the cooling towers unavailable. Plant Operations continues to monitor river conditions and may take further actions as required to maintain compliance.
"There were no safety systems challenged during the power reductions.
"This is an informational report based on media interest. TVA does not expect to make an official news release. The NRC Resident Inspector was notified."
Power Reactor
Event Number: 44393
Facility: NORTH ANNA
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: PAGE KEMP
HQ OPS Officer: JOHN KNOKE
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: PAGE KEMP
HQ OPS Officer: JOHN KNOKE
Notification Date: 08/07/2008
Notification Time: 17:26 [ET]
Event Date: 08/07/2008
Event Time: 16:00 [EDT]
Last Update Date: 08/07/2008
Notification Time: 17:26 [ET]
Event Date: 08/07/2008
Event Time: 16:00 [EDT]
Last Update Date: 08/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GEORGE HOPPER (R2)
MATTHEW HAHN (ILTA)
GEORGE HOPPER (R2)
MATTHEW HAHN (ILTA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
CIVIL DISTURBANCE AT THE NORTH ANNA NUCLEAR INFORMATION CENTER
"At 1430 hours on 8-7-08, approximately 20 individuals from a group identified as the Southeast Convergence for Climate Action arrived at the North Anna Nuclear Information Center (NANIC) and initiated a civil disturbance within the center. [The NANIC is located just inside the Owner Controlled Area]. When the NANIC closed at 1600 hours, 8 of the individuals refused to leave the building. Local Law enforcement informed the individuals that they would be placed under arrest, and 2 individuals exited the area. The remaining 6 individuals were detained by Local Law Enforcement Officers and removed from Dominion property."
Licensee has notified the NRC Resident Inspector.
"At 1430 hours on 8-7-08, approximately 20 individuals from a group identified as the Southeast Convergence for Climate Action arrived at the North Anna Nuclear Information Center (NANIC) and initiated a civil disturbance within the center. [The NANIC is located just inside the Owner Controlled Area]. When the NANIC closed at 1600 hours, 8 of the individuals refused to leave the building. Local Law enforcement informed the individuals that they would be placed under arrest, and 2 individuals exited the area. The remaining 6 individuals were detained by Local Law Enforcement Officers and removed from Dominion property."
Licensee has notified the NRC Resident Inspector.
Power Reactor
Event Number: 44394
Facility: CATAWBA
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: STEVE CHRISTOPHER
HQ OPS Officer: JOHN KNOKE
Region: 2 State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: STEVE CHRISTOPHER
HQ OPS Officer: JOHN KNOKE
Notification Date: 08/07/2008
Notification Time: 19:21 [ET]
Event Date: 08/07/2008
Event Time: 16:00 [EDT]
Last Update Date: 08/07/2008
Notification Time: 19:21 [ET]
Event Date: 08/07/2008
Event Time: 16:00 [EDT]
Last Update Date: 08/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
GEORGE HOPPER (R2)
GEORGE HOPPER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION TO SOUTH CAROLINA ENVIRONMENTAL AGENCY
"The quarterly National Pollutant Discharge Elimination System whole effluent toxicity testing for outfall #002 failed for July 2008. This required notification to the South Carolina Environmental Agency." The system was the Conventional Waste (WC).
The licensee will be notifying the NRC Resident Inspector.
"The quarterly National Pollutant Discharge Elimination System whole effluent toxicity testing for outfall #002 failed for July 2008. This required notification to the South Carolina Environmental Agency." The system was the Conventional Waste (WC).
The licensee will be notifying the NRC Resident Inspector.