Event Notification Report for July 22, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/21/2008 - 07/22/2008
Power Reactor
Event Number: 44359
Facility: INDIAN POINT
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: TIM BUCHAL
HQ OPS Officer: JASON KOZAL
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: TIM BUCHAL
HQ OPS Officer: JASON KOZAL
Notification Date: 07/22/2008
Notification Time: 20:30 [ET]
Event Date: 07/22/2008
Event Time: 18:45 [EDT]
Last Update Date: 07/22/2008
Notification Time: 20:30 [ET]
Event Date: 07/22/2008
Event Time: 18:45 [EDT]
Last Update Date: 07/22/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GLENN DENTEL (R1)
GLENN DENTEL (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OIL RELEASE TO THE ENVIRONMENT
"At 1845 an oil sheen was noticed at the discharge canal of Unit #2. A slight oil sheen has reached the Hudson River. Estimated discharge is less than 1 gallon. The source is run-off from a parking lot and other paved areas due to recent heavy rain. Oil content is lessening in the runoff.
"The licensee notified the following organizations: USCG National Response Center (Report #878141), NY Department of Environmental Conservation, and the Westchester County Department of Health.
"Cleanup is being coordinated with Miller Environmental as required."
The licensee notified the NRC Resident Inspector.
"At 1845 an oil sheen was noticed at the discharge canal of Unit #2. A slight oil sheen has reached the Hudson River. Estimated discharge is less than 1 gallon. The source is run-off from a parking lot and other paved areas due to recent heavy rain. Oil content is lessening in the runoff.
"The licensee notified the following organizations: USCG National Response Center (Report #878141), NY Department of Environmental Conservation, and the Westchester County Department of Health.
"Cleanup is being coordinated with Miller Environmental as required."
The licensee notified the NRC Resident Inspector.
Other Nuclear Material
Event Number: 44360
Rep Org: CALUMET TECHNICAL SERVICES
Licensee: CALUMET TECHNICAL SERVICES
Region: 3
City: Griffith State: IN
County:
License #: 13-16347-01
Agreement: N
Docket:
NRC Notified By: THOMAS KEILMAN
HQ OPS Officer: HOWIE CROUCH
Licensee: CALUMET TECHNICAL SERVICES
Region: 3
City: Griffith State: IN
County:
License #: 13-16347-01
Agreement: N
Docket:
NRC Notified By: THOMAS KEILMAN
HQ OPS Officer: HOWIE CROUCH
Notification Date: 07/23/2008
Notification Time: 09:38 [ET]
Event Date: 07/22/2008
Event Time: 09:30 [EDT]
Last Update Date: 07/23/2008
Notification Time: 09:38 [ET]
Event Date: 07/22/2008
Event Time: 09:30 [EDT]
Last Update Date: 07/23/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
MONTE PHILLIPS (R3)
MICHELLE BURGESS (FSME)
MONTE PHILLIPS (R3)
MICHELLE BURGESS (FSME)
SAFETY EQUIPMENT FAILURE
While conducting radiography at the Stiglitz Park Tank Farm in Lake County, Indiana, the radiographer noticed that the source failed to retract with the drive cable in his radiography camera. Upon noticing the detached source, the radiographer immediately covered the source with lead blankets and established an area boundary around the source. He then contacted the Radiation Safety Officer (RSO) who dispatched personnel to the site. There were no reported overexposures to radiography personnel as a result of this incident.
Licensee radiographers were able to retrieve the source, place it back into the camera, and transport the source and camera back to the licensee's main facility. They inspected the camera, source, drive cable and connector and did not find any damage. They were not able to determine why the source became disconnected. They reconnected the source to the camera, functionally tested it satisfactorily, and placed the camera back into service. The licensee did not have the camera vendor inspect or test the device.
The camera is an Amersham model 880, serial number D4044 with a 65 Curie Ir-192 source, serial number 45541B.
While conducting radiography at the Stiglitz Park Tank Farm in Lake County, Indiana, the radiographer noticed that the source failed to retract with the drive cable in his radiography camera. Upon noticing the detached source, the radiographer immediately covered the source with lead blankets and established an area boundary around the source. He then contacted the Radiation Safety Officer (RSO) who dispatched personnel to the site. There were no reported overexposures to radiography personnel as a result of this incident.
Licensee radiographers were able to retrieve the source, place it back into the camera, and transport the source and camera back to the licensee's main facility. They inspected the camera, source, drive cable and connector and did not find any damage. They were not able to determine why the source became disconnected. They reconnected the source to the camera, functionally tested it satisfactorily, and placed the camera back into service. The licensee did not have the camera vendor inspect or test the device.
The camera is an Amersham model 880, serial number D4044 with a 65 Curie Ir-192 source, serial number 45541B.