Event Notification Report for July 17, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/16/2008 - 07/17/2008

EVENT NUMBERS
4435445656

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 44354
Facility: BRAIDWOOD
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RYAN FRUTH
HQ OPS Officer: BILL HUFFMAN
Notification Date: 07/17/2008
Notification Time: 19:53 [ET]
Event Date: 07/17/2008
Event Time: 11:41 [CDT]
Last Update Date: 09/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
JULIO LARA (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
DEGRADED CONTROL ROOM VENTILATION ENVELOPE

"At 1141 on Thursday, July 17, 2008, Braidwood Station determined that the Control Room Envelope (CRE) boundary had a degraded condition based on data obtained during performance of differential pressure testing performed in accordance with Technical Specification (TS) 5.5.18, 'Control Room Envelope Habitability Program.' Degradation of the CRE boundary was identified that could have prevented the Control Room (VC) Ventilation Filtration System from performing its safety function due to the potential for a greater amount of unfiltered inleakage into the CRE than assumed in the licensing basis analysis for Design Basis Accident consequences. The differential pressure test results identified slightly negative pressures as compared to outside air in some areas of the CRE that do not include spaces that control room occupants inhabit during accident conditions.

"In accordance with the requirements of TS 3.7.10, 'VC Filtration System,' Condition B, mitigating actions have been implemented to lessen the effect on CRE occupants from the potential hazards of a radiological or chemical event or a challenge from smoke. Actions are in progress to resolve the CRE degraded condition.

"This event is being reported under 10CFR50.72(b)(3)(v)(D) as an 8-hour report as a condition that at the time of discovery could have prevented the fulfillment of the safety function of a system needed to mitigate the consequences of an accident. A Licensee Event Report will be submitted under 10CFR50.73(a)(2)(v).

"The licensee informed the NRC resident."

* * * UPDATE AT 1300 EDT ON 09/10/08 FROM RYAN FRUTH TO S. SANDIN * * *

The licensee is retracting this report based on the following:

"On July 17, 2008, NRC Notification 44354 was conservatively made pursuant to 10 CFR 50.72(b)(3)(v)(D) related to the failure of a control room envelope (CRE) differential pressure test. This was the first time this test methodology had been used at Braidwood Station. Specifically, based on the test results, the unfiltered CRE inleakage could not be confirmed as being bounded by the values assumed within the accident dose analyses and hence the Control Room Ventilation (VC) Filtration System could have been prevented from performing its specified safety function. Subsequent evaluation has determined that the VC Filtration System was capable of performing its specified safety function to maintain CRE habitability, since the identified condition would not have resulted in a greater amount of unfiltered inleakage into the CRE than assumed in the licensing bases analyses. Therefore, this event notification is being retracted.

"The causes for the test failure were attributable to an incorrect test methodology and minor CRE boundary imperfections that had existed since plant construction. These CRE minor imperfections were present during performance of the last CRE unfiltered air inleakage test performed in 2004, which produced acceptable results. Both of these causes were corrected and the test reperformed with acceptable results.

"Evaluation of this event notification is documented in the corrective action program.

"The NRC resident has been notified of this retraction."

Notified R3DO (Passehl).


General Information or Other
Event Number: 45656
Rep Org: PA BUREAU OF RADIATION PROTECTION
Licensee: LEHIGH VALLEY HOSPITAL
Region: 1
City: ALLENTOWN   State: PA
County:
License #: PA-0232
Agreement: Y
Docket:
NRC Notified By: DAVID ALLARD
HQ OPS Officer: JOE O'HARA
Notification Date: 01/25/2010
Notification Time: 22:01 [ET]
Event Date: 07/17/2008
Event Time: 00:00 [EST]
Last Update Date: 01/25/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
SAM HANSELL (R1DO)
LARRY CAMPER (FSME)
Event Text
AGREEMENT STATE REPORT- MEDICAL OVEREXPOSURE EVENT

The following information was received via fax:

"On July 17, 2008 the PA DEP SERO [Pennsylvania Department of Environmental Protection Southeast Regional Office] was notified of a medical event at Lehigh Valley Hospital. Two patients were scheduled for different I-131 therapy doses and the doses got switched. The first patient was prescribed 20 mCi but was administered 75 mCi. The event took place on July 17, 2008. Both the patient and the physician were informed. The patient was given a blocking agent of 130mg SSKI approximately 1 hour after uptake of the I-131. Next day measurements indicated 2 mCi uptake to the thyroid and 10 mCi whole body retention. A procedure modification has been put into place to prevent this from occurring again. Also a Notice of Violation was sent to the hospital."

Event Report ID No: PA080021


A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.