Event Notification Report for July 07, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/06/2008 - 07/07/2008
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 44339
Facility: MCGUIRE
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MICHAEL RICHARDSON
HQ OPS Officer: JOHN KNOKE
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MICHAEL RICHARDSON
HQ OPS Officer: JOHN KNOKE
Notification Date: 07/07/2008
Notification Time: 16:54 [ET]
Event Date: 07/07/2008
Event Time: 14:22 [EDT]
Last Update Date: 09/10/2008
Notification Time: 16:54 [ET]
Event Date: 07/07/2008
Event Time: 14:22 [EDT]
Last Update Date: 09/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
MARVIN SYKES (R2)
MARVIN SYKES (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
FAILURE OF THE ALERT NOTIFICATION SYSTEM
Alert Notification sirens (60 of 67) failed to operate properly and therefore required licensee to report this per 10 CFR 50.72(b)(3)(xiii). All Emergency Planning Zone counties have been notified and placed on backup route alerting, which means notification will be performed by local authorities. Investigation of this matter is ongoing.
Licensee has notified NRC Resident Inspector.
* * * UPDATE FROM MICHAEL RICHARDSON TO JOHN KNOKE AT 1435 EDT ON 07/08/08 * * *
A bad radio in the test shop created interference with the Alert Notification sirens, thus preventing them from operating properly. At 1425 EDT all Emergency Planning Zone counties were notified and the backup route alerting was cancelled. The sirens were tested satisfactorily multiple times.
Licensee has notified NRC Resident Inspector. Notified R2DO (Guthrie)
* * *RETRACTION PROVIDED AT 1744 EDT ON 09/10/08 FROM ROGER DEHART TO JEFF ROTTON * * *
Telecom investigation revealed that all 67 ANS sirens were in fact available and ANS siren failure did not occur. The polling feature of the ANS sirens feedback signal experienced radio interference from a standby radio. This interference in the feedback system of the radio/siren system did not interfere with the activation of the sirens. The ANS sirens were fully functional and available during this time, therefore notification 44339 is being retracted.
The licensee notified the NRC Resident Inspector. Notified R2DO (Payne)
Alert Notification sirens (60 of 67) failed to operate properly and therefore required licensee to report this per 10 CFR 50.72(b)(3)(xiii). All Emergency Planning Zone counties have been notified and placed on backup route alerting, which means notification will be performed by local authorities. Investigation of this matter is ongoing.
Licensee has notified NRC Resident Inspector.
* * * UPDATE FROM MICHAEL RICHARDSON TO JOHN KNOKE AT 1435 EDT ON 07/08/08 * * *
A bad radio in the test shop created interference with the Alert Notification sirens, thus preventing them from operating properly. At 1425 EDT all Emergency Planning Zone counties were notified and the backup route alerting was cancelled. The sirens were tested satisfactorily multiple times.
Licensee has notified NRC Resident Inspector. Notified R2DO (Guthrie)
* * *RETRACTION PROVIDED AT 1744 EDT ON 09/10/08 FROM ROGER DEHART TO JEFF ROTTON * * *
Telecom investigation revealed that all 67 ANS sirens were in fact available and ANS siren failure did not occur. The polling feature of the ANS sirens feedback signal experienced radio interference from a standby radio. This interference in the feedback system of the radio/siren system did not interfere with the activation of the sirens. The ANS sirens were fully functional and available during this time, therefore notification 44339 is being retracted.
The licensee notified the NRC Resident Inspector. Notified R2DO (Payne)
Power Reactor
Event Number: 45631
Facility: SOUTH TEXAS
Region: 4 State: TX
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RON GIBBS
HQ OPS Officer: JOE O'HARA
Region: 4 State: TX
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RON GIBBS
HQ OPS Officer: JOE O'HARA
Notification Date: 01/14/2010
Notification Time: 17:59 [ET]
Event Date: 07/07/2008
Event Time: 21:47 [CST]
Last Update Date: 01/14/2010
Notification Time: 17:59 [ET]
Event Date: 07/07/2008
Event Time: 21:47 [CST]
Last Update Date: 01/14/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
10 CFR Section:
50.72(b)(3)(ii)(B) - UNANALYZED CONDITION
Person (Organization):
LINDA HOWELL (R4DO)
LINDA HOWELL (R4DO)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF FIRE SUPPRESSION CAPABILITY
"This is an 8-hour notification being made in accordance with 10CFR 50.72(b)(3)(ii)(B) for an event or condition that results in the plant being in an unanalyzed condition that significantly degrades plant safety.
"This notification is being made as the result of the re-review of a July 7, 2008 occurrence which resulted in an inadvertent isolation of a large portion of the [fire suppression] ring header affecting all Unit 2 fire suppression and a portion of Unit 1 fire suppression. The Unit 1 ring header isolation did not have an affect on the fire safe shutdown capability of Unit 1. However, three areas in Unit 2 which credit the availability of fire suppression to assure that the safe shutdown capability could have been achieved did not have fire suppression for approximately 3 hours.
"A Licensee Event Report will be submitted within 60 days."
The licensee notified the NRC Resident Inspector.
"This is an 8-hour notification being made in accordance with 10CFR 50.72(b)(3)(ii)(B) for an event or condition that results in the plant being in an unanalyzed condition that significantly degrades plant safety.
"This notification is being made as the result of the re-review of a July 7, 2008 occurrence which resulted in an inadvertent isolation of a large portion of the [fire suppression] ring header affecting all Unit 2 fire suppression and a portion of Unit 1 fire suppression. The Unit 1 ring header isolation did not have an affect on the fire safe shutdown capability of Unit 1. However, three areas in Unit 2 which credit the availability of fire suppression to assure that the safe shutdown capability could have been achieved did not have fire suppression for approximately 3 hours.
"A Licensee Event Report will be submitted within 60 days."
The licensee notified the NRC Resident Inspector.