Event Notification Report for May 07, 2008
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
05/06/2008 - 05/07/2008
Power Reactor
Event Number: 44191
Facility: COMANCHE PEAK
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MIKE STAKES
HQ OPS Officer: KARL DIEDERICH
Region: 4 State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MIKE STAKES
HQ OPS Officer: KARL DIEDERICH
Notification Date: 05/07/2008
Notification Time: 18:02 [ET]
Event Date: 05/07/2008
Event Time: 11:00 [CDT]
Last Update Date: 05/07/2008
Notification Time: 18:02 [ET]
Event Date: 05/07/2008
Event Time: 11:00 [CDT]
Last Update Date: 05/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
DAVID PROULX (R4)
DAVID PROULX (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF MULTIPLEXER POWER SUPPLY
"Plant computer multiplexer power supply has failed resulting in a loss of some monitoring capabilities. Included are: ICRR [Inverse Count Rate Ratio], Digital Reactivity calculations, axial flux difference, meteorological inputs, main steam safety indication, source range, intermediate range, power range, and containment humidity. Control board indications remain available, for assessment of above functions."
The licensee is implementing procedural compensatory measures.
The licensee has notified the NRC Resident Inspector.
"Plant computer multiplexer power supply has failed resulting in a loss of some monitoring capabilities. Included are: ICRR [Inverse Count Rate Ratio], Digital Reactivity calculations, axial flux difference, meteorological inputs, main steam safety indication, source range, intermediate range, power range, and containment humidity. Control board indications remain available, for assessment of above functions."
The licensee is implementing procedural compensatory measures.
The licensee has notified the NRC Resident Inspector.
Other Nuclear Material
Event Number: 44194
Rep Org: WASHINGTON UNIVERSITY IN ST LOUIS
Licensee: WASHINGTON UNIVERSITY IN ST LOUIS
Region: 3
City: ST. LOUIS State: MO
County:
License #: 24-00167-11
Agreement: N
Docket:
NRC Notified By: SUSAN LANGHORST
HQ OPS Officer: JEFF ROTTON
Licensee: WASHINGTON UNIVERSITY IN ST LOUIS
Region: 3
City: ST. LOUIS State: MO
County:
License #: 24-00167-11
Agreement: N
Docket:
NRC Notified By: SUSAN LANGHORST
HQ OPS Officer: JEFF ROTTON
Notification Date: 05/08/2008
Notification Time: 17:30 [ET]
Event Date: 05/07/2008
Event Time: 16:35 [CDT]
Last Update Date: 05/08/2008
Notification Time: 17:30 [ET]
Event Date: 05/07/2008
Event Time: 16:35 [CDT]
Last Update Date: 05/08/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
RICHARD SKOKOWSKI (R3)
TERRANCE REIS (FSME)
ILTAB (via email)
RICHARD SKOKOWSKI (R3)
TERRANCE REIS (FSME)
ILTAB (via email)
LOST I-125 SEEDS
RSO reported that two I-125 seeds have been lost following a prostate implant procedure. Seeds have an apparent activity of 0.37 milliCuries each, and actual contained activity of 0.518 milliCuries each. Facility received 15 seeds from the seed manufacturer for a scheduled prostate implant procedure at 0900 CDT on 05/07/08. 13 seeds were implanted successfully by the authorized user. After the procedure was completed, the technologist completed surveys around the patient and in the area of the procedure. At this time, it is believed that the technologist disassembled the MIC applicator improperly and left a part in the MIC that contained the seeds. The technologist did not verify, visually or by survey, that the seeds were contained in the part of the MIC applicator that was going to storage. It is believed that the seeds went with the part of the MIC unit that went into a soap basin for cleaning and that during cycling of the plunger the seeds came out and went into the soap basin and down the drain into the buildings sanitary sewer system. The loss was not identified until 1630 on 05/07/08, when the medical physicist was going to use the two remaining seeds for other testing. Several medical physicists from Radiation/Oncology went to survey the operating room area used for the procedure and were unsuccessful in locating either seed. At 1830, Radiation Safety organization was notified and the facility continued looking for the missing seeds. A survey was performed on the drain trap area of the soap basin and no increased background was identified. The facility does not believe that the seeds will be recovered. The investigation is still ongoing.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source
RSO reported that two I-125 seeds have been lost following a prostate implant procedure. Seeds have an apparent activity of 0.37 milliCuries each, and actual contained activity of 0.518 milliCuries each. Facility received 15 seeds from the seed manufacturer for a scheduled prostate implant procedure at 0900 CDT on 05/07/08. 13 seeds were implanted successfully by the authorized user. After the procedure was completed, the technologist completed surveys around the patient and in the area of the procedure. At this time, it is believed that the technologist disassembled the MIC applicator improperly and left a part in the MIC that contained the seeds. The technologist did not verify, visually or by survey, that the seeds were contained in the part of the MIC applicator that was going to storage. It is believed that the seeds went with the part of the MIC unit that went into a soap basin for cleaning and that during cycling of the plunger the seeds came out and went into the soap basin and down the drain into the buildings sanitary sewer system. The loss was not identified until 1630 on 05/07/08, when the medical physicist was going to use the two remaining seeds for other testing. Several medical physicists from Radiation/Oncology went to survey the operating room area used for the procedure and were unsuccessful in locating either seed. At 1830, Radiation Safety organization was notified and the facility continued looking for the missing seeds. A survey was performed on the drain trap area of the soap basin and no increased background was identified. The facility does not believe that the seeds will be recovered. The investigation is still ongoing.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source
General Information or Other
Event Number: 44266
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: WAL-MART
Region: 4
City: State: LA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: HOWIE CROUCH
Licensee: WAL-MART
Region: 4
City: State: LA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: HOWIE CROUCH
Notification Date: 06/04/2008
Notification Time: 14:05 [ET]
Event Date: 05/07/2008
Event Time: 00:00 [CDT]
Last Update Date: 06/04/2008
Notification Time: 14:05 [ET]
Event Date: 05/07/2008
Event Time: 00:00 [CDT]
Last Update Date: 06/04/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JACK WHITTEN (R4)
MICHELE BURGESS (FSME)
JACK WHITTEN (R4)
MICHELE BURGESS (FSME)
LOUISIANA AGREEMENT STATE REPORT - BROKEN TRITIUM EXIT SIGNS
On May, 7, 2008, Wal-Mart reported six broken Tritium Exit Signs (TES). Three TES were located at a store in Baker, LA and three were located in a store in Baton Rouge, LA. Wal-Mart has hired Shaw Group, Inc. for its company-wide program to inventory and manage TES. Shaw Group performed decontamination of the affected stores and shipped the broken TES to a licensed source disposal facility. All the TES were located in non-public areas of the stores.
LA Event Report: LA0800013
On May, 7, 2008, Wal-Mart reported six broken Tritium Exit Signs (TES). Three TES were located at a store in Baker, LA and three were located in a store in Baton Rouge, LA. Wal-Mart has hired Shaw Group, Inc. for its company-wide program to inventory and manage TES. Shaw Group performed decontamination of the affected stores and shipped the broken TES to a licensed source disposal facility. All the TES were located in non-public areas of the stores.
LA Event Report: LA0800013