Skip to main content

Event Notification Report for April 06, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/05/2008 - 04/06/2008

EVENT NUMBERS
44121

Power Reactor
Event Number: 44121
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: DAVID BALFOUR
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 04/06/2008
Notification Time: 14:13 [ET]
Event Date: 04/06/2008
Event Time: 13:17 [EDT]
Last Update Date: 04/07/2008
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
SAM HANSELL (R1)
THEODORE QUAY (NRR)
JIM DYER (NRR)
JEFFREY CRUZ (IRD)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
UNUSUAL EVENT FROM REACTOR COOLANT SYSTEM LEAKAGE

Millstone unit 2 entered a refueling outage on 4/6/2008. The plant was in the process of placing shutdown cooling in service when at 1236 a 10-15 gpm leak was detected by decreasing pressurizer level. The release path was determined to be from the Reactor Coolant System (RCS) to the Refueling Water Storage Tank (RWST). Pressurizer level is stable and RWST level is rising slowly. Two charging pumps are available for RCS makeup. Decay heat is being removed with Atmospheric Dump Valves. The vent line on the RWST does not contain a radiation monitor and this is an potential unmonitored radiation release path.

The Unusual Event was declared at 1317. The leak was terminated at 1320. Monitoring of the potential release path commenced at 1610.

The licensee notified the NRC Resident Inspector.

* * * UPDATE ON 4/6/2008 AT 1910 FROM WAYNE GAMMON TO MARK ABRAMOVITZ * * *

"The leak path has been isolated by closing the two air operated ECCS recirc header stops 2-SI-659/660."

The Unusual Event was terminated at 1856 and the NRC exited "monitoring mode" at 1920.

Notified IRD (Cruz), NRR EO (Quay), and R1DO (Hansell).

EPA Incident Report Number: 867171

The licensee notified the NRC Resident Inspector.

* * * UPDATE ON 4/07/08 @ 1110 EDT FROM JIM KUNZE TO HOWIE CROUCH * * *

"Upon further review, the times that the RCS leak occurred and was isolated require correction. The RCS leak occurred at 1243 when valve 2-SI-651 was opened to place shutdown cooling in service. The leak was terminated at 1356 when valve 2-Sl-659 was closed.

"The NRC Sr. Resident Inspector has been notified."

Notified R1DO (Conte).