Skip to main content

Event Notification Report for March 27, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/26/2008 - 03/27/2008

EVENT NUMBERS
441014410244103

Other Nuclear Material
Event Number: 44101
Rep Org: HIRO MAKINO
Licensee: HIRO MAKINO
Region: 4
City: AIEA   State: HI
County:
License #: 53-29263-01
Agreement: N
Docket:
NRC Notified By: RONALD FRICK
HQ OPS Officer: JEFF ROTTON
Notification Date: 03/27/2008
Notification Time: 17:58 [ET]
Event Date: 03/27/2008
Event Time: 10:00 [HST]
Last Update Date: 03/27/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
20.1906(d)(2) - EXTERNAL RAD LEVELS > LIMITS
Person (Organization):
VINCENT GADDY (R4)
KEITH McCONNELL (FSME)
Event Text
PACKAGE EXTERNAL CONTAMINATION ABOVE LIMITS

At 1000 HST on 03/27/08 a package containing 3 unit doses of Tech 99 (M) was delivered by Pacific Radiopharmacy to the licensee. Wipe survey of shipping bag handle revealed 20000 dpm on a 300 square centimeter wipe. A single wipe of all three unit dose pigs revealed 14000 dpm. The delivery carrier was notified and reported that no contamination was found on the transport vehicle or the driver. The unit dose pigs were decontaminated and the shipping bag was stored for decay.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 44102
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: TOM HACKLER
HQ OPS Officer: PETE SNYDER
Notification Date: 03/27/2008
Notification Time: 20:27 [ET]
Event Date: 03/27/2008
Event Time: 16:45 [EDT]
Last Update Date: 05/23/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
JAY HENSON (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
UNACCEPTABLE FLAW FOUND IN RPV CAP TO PIPE WELD

"At 1645 EDT, it was determined that an unacceptable flaw existed in reactor pressure vessel penetration N9. This penetration leads to a capped line and the flaw is in the cap-to-pipe weld. Based on manual ultrasonic examination, the flaw is 6.2 inches in length on a 5.5 inch OD pipe. Using non-qualified ultrasonic sizing techniques, the flaw is estimated to have a maximum depth of 30 percent through-wall. The flaw was discovered during in-service inspection examination of this penetration, using an improved technique compared to the technique used during a 2004 inspection. The flaw has been found unacceptable per paragraph IWB-3514.4 of the 1989 Edition of ASME Section XI Code and is therefore reportable. A weld overlay repair is being planned.

"The safety significance of this is minimal. Unit 1 is currently in a refueling outage. Repairs of the affected weld will be completed prior to startup."

The licensee notified the NRC Resident Inspector.

* * * RETRACTION PROVIDED BY BILL MURRAY TO JASON KOZAL AT 0946 ON 5/23/08 * * *

"On March 27,2008, at 2027 hours, the Control Room Supervisor made a notification (Event Number 44102) to the NRC Operations Center in Accordance with 10 CFR 50.72(b)(3)(ii)(A) (i.e., any event or condition that results in the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded). The notification was made as a result of determining that an unacceptable flaw existed in the reactor pressure vessel penetration N9 (control rod drive system return line) nozzle-to-pipe cap weld. At the time of discovery, based on manual ultrasonic examination, the flaw was determined to be 6.2 inches in length on a 5.5-inch OD pipe. Using non-qualified ultrasonic depth sizing techniques, the flaw was estimated to have a maximum depth of 30 percent through-wall. The flaw was found unacceptable in accordance with paragraph IWB-3514.4 of the 1989 Edition of ASME Code, Section XI and therefore was reportable.

"Basis for Retraction

"On March 30, 2008, manually indexed phased-array ultrasonic examination of the CRD return line nozzle-to-array caw weld was preformed. Based on these inspections, it was determined that the indication does not exhibit stress corrosion cracking characteristics and is not consistent with ultrasonic responses associated with inside diameter (ID) connected geometry. Therefore, the CRD return line nozzle-to-pipe cap weld is acceptable from an ASME Code Section XI perspective. On this basis, the indication did not result in the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded and the issue is not reportable under 10 CFR 50,72(b)(3)(ii)(A).

"Investigation of this condition is documented in the corrective action program in Nuclear Condition Report (NCR) 272454.

"The NRC resident was notified of this retraction."

Notified R2DO (Vias).


Power Reactor
Event Number: 44103
Facility: SEABROOK
Region: 1     State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: MIKE TAYLOR
HQ OPS Officer: PETE SNYDER
Notification Date: 03/27/2008
Notification Time: 21:38 [ET]
Event Date: 03/27/2008
Event Time: 19:07 [EDT]
Last Update Date: 03/27/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
RONALD BELLAMY (R1)
MARY JANE ROSS-LEE (NRR)
BRIAN McDERMOTT (IRD)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FATALITY OF LICENSEE EMPLOYEE

"OSHA was notified at 2055 on 3/17/08, under 29 CFR 1904, of the fatality of an employee caused by an apparent heart attack while at work."

The licensee notified the NRC Resident Inspector.