Skip to main content

Event Notification Report for February 12, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/11/2008 - 02/12/2008

EVENT NUMBERS
4398144000

Fuel Cycle Facility
Event Number: 43981
Facility: WESTINGHOUSE ELECTRIC CORPORATION
Region: 2     State: SC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: GERARD COUTURE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 02/12/2008
Notification Time: 19:58 [ET]
Event Date: 02/12/2008
Event Time: 19:45 [EST]
Last Update Date: 02/12/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
EUGENE GUTHRIE (R2)
ABY MOHSENI (NMSS)
ROBERT LEWIS (FSME)
ILTAB VIA E-MAIL
Event Text
LOSS OF ENRICHED URANIUM HEXAFLUORIDE IN SAMPLE VIALS

"Reason for Notification: During preparation of receipt transaction documentation (NRC 741) it was discovered that results of laboratory analysis for two [shipping] containers containing 16, P-10 sample tubes of UF6 [uranium hexafluoride] could not be located. Upon further investigation, neither the vials nor [shipping] containers could be located in the laboratory or on site. The vials contain a total of 128 Grams Uranium (6 grams Uranium 235) enriched to 4.95 wt%. This is approximately 409.4 micro-curies. It was determined that on 02/04/2008, 2 metal pails each containing (8) UF6 P-10 sample tubes were received in the Shipping & Receiving (S/R) department. One of the containers was dented upon receipt. S/R notified Health Physics to have the containers surveyed; they were cleared to the lab. However, the lab could not confirm that the P-10 vials containing uranium had been unloaded from the containers. One employee recalls surveying at least one of the containers, removing the labels and placing the containers out on Dock #11 for disposal.

"Notification is being made based on [10 CFR 20.2201] (a) Telephone reports. (1) Each licensee shall report by telephone as follows: (i) Immediately after its occurrence becomes known to the licensee, any lost, stolen, or missing licensed material in an aggregate quantity equal to or greater than 1,000 times the quantity specified in Appendix C to Part 20 under such circumstances that it appears to the licensee that an exposure could result to persons in unrestricted areas.

"Safety Basis: These vials were secured in containers authorized for shipment, which were surveyed by Health Physics upon receipt with no indication of leakage. It is postulated these [shipping] containers [with the sample vials still in the containers] have been inadvertently sent to either a waste landfill or scrap metal dealer.

"Summary of Activity:
- Columbia Fuel Site laboratories and waste processing facilities have been searched.
- Interviews with affiliated staff have confirmed packages were staged for waste disposal.
- Westinghouse notification to Richland County South Carolina, and South Carolina Department of Health and Environmental Control will follow immediately.
- Event entered into Corrective Action Process (CAPS# 08-043-C004)"

The licensee stated that the vials are approximately 2 inches long and between 1/8 to 1/4 inch in diameter. The vials were made of plastic with metal end caps. These vials are typically packed in Styrofoam in the shipping containers and their presence in the shipping containers may not be readily determined by just looking into the containers.



THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


General Information or Other
Event Number: 44000
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: MARRIOTT RESIDENCE INN
Region: 4
City: SACREMENTO   State: CA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: BARBARA HAMRICK
HQ OPS Officer: JOE O'HARA
Notification Date: 02/21/2008
Notification Time: 13:50 [ET]
Event Date: 02/12/2008
Event Time: 00:00 [PST]
Last Update Date: 02/21/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
LINDA HOWELL (R4)
GREG MORELL (FSME)
Event Text
AGREEMENT STATE REPORT - BROKEN TRITIUM SIGNS

The State provided the following information via email:

"On February 12, 2008, the maintenance engineer from the Residence Inn in Corona, CA contacted RHB headquarters and left a message regarding two broken tritium exit signs. The message was not referred to the South RM ICE office until February 21, 2008. On February 21, 2008, [the State] dispatched an inspector to assess the situation, and ensure the signs are isolated and contained, until disposal can be arranged. The general licensee will also be requested to obtain a health physics consultant to assess potential exposures."

CA NMED # 022108

* * * UPDATE FROM DONELLE KRAJEWSKI TO JOE O'HARA VIA E-MAIL AT 1704 ON 02/21/08 * * *

"There were 2 tritium exit signs whose plexi-glass fronts were cracked. The H-3 tubes do appear to be ruptured since the letters are not completely and evenly lighted when you view the signs in a darkened room.

"Each exit sign contained 0.426 TBq (11.5 Curies) H-3. Manufacturer - Shield Source Inc, Petersbourgh, Canada, Model 101, Distributed by - Safety Light Corp, Bloomsburg, PA 17815. The serial numbers are #U9453 and T7844.

"Wipes were taken from the face of the signs and in the surrounding area, but it will be a couple of weeks before we get the results. The signs were individually packaged in plastic and were placed in a 5 gallon pail which will remain in a secure area until disposal by an authorized waste broker."

Notified R4DO (Howell, L.) and FSME (Suber).