Skip to main content

Event Notification Report for January 16, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/15/2008 - 01/16/2008

EVENT NUMBERS
4390943915

Power Reactor
Event Number: 43909
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHRIS REEVES
HQ OPS Officer: JEFF ROTTON
Notification Date: 01/16/2008
Notification Time: 21:15 [ET]
Event Date: 01/16/2008
Event Time: 19:25 [EST]
Last Update Date: 01/16/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JAMES MOORMAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP DUE TO LOWERING STEAM GENERATOR LEVEL

During a surveillance test on the Loop 3 Steam Generator pressure channel, the loop 3 Steam Generator main feedwater regulating valve went closed. The unit was manually tripped on lowering steam generator level. All control rods fully inserted on the reactor trip. Both motor driven and the turbine driven AFW pumps started successfully. The turbine driven AFW pump was secured and the motor driven AFW pumps are providing feedwater to the steam generators. Decay heat is being removed to the main condenser via the turbine steam dump valves. No PORV, safety relief valves, or atmospheric dump valves opened on the reactor trip. Unit 1 is in a normal shutdown electrical lineup. There was no effect on Unit 2 during this event. The licensee is investigating the unexpected closure of the Loop 3 Steam Generator main feedwater regulating valve.

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 43915
Rep Org: TENNESSEE DIV OF RAD HEALTH
Licensee: DURATEK RADWASTE PROCESSING, INC.
Region: 1
City: OAK RIDGE   State: TN
County: ROANE
License #: R-73008
Agreement: Y
Docket:
NRC Notified By: DEBRA SHULTS
HQ OPS Officer: STEVE SANDIN
Notification Date: 01/18/2008
Notification Time: 10:32 [ET]
Event Date: 01/16/2008
Event Time: 12:30 [EST]
Last Update Date: 01/18/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
EUGENE COBEY (R1)
SANDRA WASTLER (FSME)
Event Text
AGREEMENT STATE REPORT INVOLVING A LEAKING SEALED SOURCE WITH CONTAMINATION

The following information was provided via fax:

"Duratek called DRH at approx. 1430 EST Jan. 17, 2008 to report a contamination event which required control of an area of their building for greater than 24 hours. While unpackaging a sealed source that was sent to them for processing for disposal, the container which the source was in was found to be contaminated. An area of about 10' by 10', covered with herculite, was contaminated and an area of 20' by 50' is being access controlled. Three personnel working at the scene were contaminated with the maximum contamination found on the personnel being 300 cpm alpha. The source was a 140 µCi U-232 solid source from the Portsmouth Facility in Ohio. The source was re-secured in containers and the contaminated area is being decontaminated. Max contamination levels on container were 400,000 dpm/100 cm2 beta/gamma and 100,000 dpm/100 cm2 alpha. The personnel were decontaminated and had lung counts. Lung counts for all were negative for elevated intake. Fecal bioassays were initiated and are ongoing.

"Media attention: None at this time.

"Event Report ID No.: TN-08-005"