Event Notification Report for January 10, 2008

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/09/2008 - 01/10/2008

EVENT NUMBERS
43888438904389143892438934403146277

Power Reactor
Event Number: 43888
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [3] [] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: PAUL REIMERS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 01/10/2008
Notification Time: 05:37 [ET]
Event Date: 01/10/2008
Event Time: 05:02 [EST]
Last Update Date: 01/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
DAVID AYRES (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 99 Power Operation
Event Text
TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO TWO ROD POSITION INDICATORS (RPIs) OUT IN ONE ROD BANK

"At 0408 EST [the licensee] entered into TS 3.0.3 due to an observed RPI B-10 erratic indication. This RPI is in the same bank as currently inoperable F-2 RPI. TS 3.1.3.2 has actions for a maximum of one RPI per bank inoperable. Since there are two [RPIs inoperable] in one bank, an entry into TS 3.0.3 is required.

"Power reduction was initiated at 0502.

"Repairs are currently in progress and [the licensee] anticipates correction prior to completion of the power reduction."

The licensee notified the NRC Resident Inspector.

* * * UPDATE FROM NIELSEN TO HUFFMAN AT 0755 EDT ON 01/10/08 * * *

The licensee reports that repairs have been completed to RPI B-10 and it has been returned to service. Technical Specification 3.0.3 was exited at 0625. Reactor power has been returned to 100%.

The NRC Resident Inspector will be notified. The R2DO (Ayres) has been informed.


General Information or Other
Event Number: 43890
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: QUALITY SERVICES LABS / CONAM
Region: 4
City: BATON ROUGE   State: LA
County:
License #: LA-10986-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: PETE SNYDER
Notification Date: 01/10/2008
Notification Time: 12:44 [ET]
Event Date: 01/10/2008
Event Time: 00:00 [CST]
Last Update Date: 01/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
MICHELE BURGESS (FSME)
Event Text
AGREEMENT STATE REPORT - POTENTIAL EXCESSIVE EXPOSURE

The agreement state submitted the following information via e-mail:

"On January 10, 2008, CONAM reported an accidental, excessive exposure to an industrial radiographers badge. The badge reading for the month of November 2007 was 11,592 millirem. At the end of his shift, the radiographer put his personnel monitor in his work bag. The shift that came in after him used his work bag and had the bag next to the radiography camera during exposures.

"The licensee believes that this exposure was to the badge and not to the radiographer. The licensee will be sending a written report within 30 days. [The State of Louisiana] will forward new information when it is received."

Louisiana Event Report ID: LA070032


Power Reactor
Event Number: 43891
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: MICHAEL D. HUNTER
HQ OPS Officer: KARL DIEDERICH
Notification Date: 01/10/2008
Notification Time: 15:08 [ET]
Event Date: 01/10/2008
Event Time: 12:21 [CST]
Last Update Date: 01/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
MALCOLM WIDMANN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
OFFSITE NOTIFICATION - SPILL OF WATER CONTAINING TRITIUM

"This is a voluntary notification for a spill of water containing tritium as specified in section 2.2.a.iii, of Nuclear Energy Institute document NEI 07- 07 entitled 'Industry Groundwater Protection Initiative.' On January 5, 2008 at 13:55, Browns Ferry Nuclear (BFN) Plant operations personnel received a high water level alarm on a sump located within the plant, at the Condensate Piping Tunnel. The high water level was corrected within 3 hours of the alarm. Investigation into this condition determined that the water came from an overflow of the Unit 3 Condensate Storage Tank into the tunnel as a result of failed tank level instrumentation. The water was immediately transferred to the plant radioactive waste system for processing. Laboratory analysis results received on January 9, 2008 indicated this water contained 2.2 E-03 uCi/ml tritium. Based on the tunnel construction, there is a potential for a small amount of this water to permeate into the ground. Subsequent to the spill, a sample obtained from the ground water sampling well adjacent to the tunnel showed no detectable level of tritium. BFN routinely monitors the ground water for radioactivity in accordance with the NEI Groundwater Protection Initiative. Tritium levels at BFN have never reached or exceeded the Environmental Protection Agency drinking water limit. This spill was contained within the plant structure and will not increase the dose to the public. As such, this event poses no threat to public health or safety.

"The licensee notified the NRC Resident Inspector.

"This event is reportable as a 4-hour Non-Emergency Notification report in accordance with 10CFR50.72(b)(2)(xi) Any event or situation, related to the heath and safety of the public or onsite personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made."


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 43892
Facility: WOLF CREEK
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: JAMES M. KURAS
HQ OPS Officer: KARL DIEDERICH
Notification Date: 01/10/2008
Notification Time: 20:34 [ET]
Event Date: 01/10/2008
Event Time: 18:12 [CST]
Last Update Date: 03/07/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(A) - POT UNABLE TO SAFE SD 50.72(b)(3)(v)(B) - POT RHR INOP 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
RUSSELL BYWATER (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
VOIDING DISCOVERED IN HIGH HEAD AND INTERMEDIATE HEAD SI COMMON SUCTION

"Both centrifugal charging pumps and both safety injection pumps [were] declared inoperable due to 5% to 7% voiding identified in a portion of common suction piping. [The] pumps were inoperable for 27 minutes. [The] line was vented to remove [the] void and [the] pumps restored to operable. (These pumps are the High Head and Intermediate Head Emergency Core Cooling Pumps.)"

The source of the voiding is not understood and is under investigation. All systems functioned as required.

R4DO (Bywater) notified.

The licensee has notified the NRC Resident Inspector.

* * * UPDATE FROM PRESTON LAWSON TO P. SNYDER AT 1733 ON 3/7/08 * * *

Wolf Creek engineering evaluated the effects of the voids found in the common suction piping for the high head and the intermediate head emergency core cooling pumps. The pumps and their systems would have been able to perform their intended safety functions.

The licensee will notify the NRC Resident Inspector.

Notified R4DO (Cain).


Power Reactor
Event Number: 43893
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [1] [2] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: TIM A. GOLDEN
HQ OPS Officer: PETE SNYDER
Notification Date: 01/10/2008
Notification Time: 20:41 [ET]
Event Date: 01/10/2008
Event Time: 16:00 [CST]
Last Update Date: 01/10/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
MALCOLM WIDMANN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
INADVERTENT ACTUATION OF OFFSITE EMERGENCY SIREN

"At 1600 on 1/10/2008 the Control Room was notified by [Offsite Duty System engineer] (ODS) that at 1515, one offsite emergency siren (siren # 54) inadvertently actuated for approximately 3 minutes in Tanner. This required ODS to notify the Alabama Emergency Management Agency. The siren is located within the 10 mile EPZ for BFNP. Due to inclement weather a Tornado Watch was in effect at the time. The siren is currently operable.

"The licensee notified the NRC Resident Inspector.

"This event is reportable as a 4 hour Non-Emergency Notification report in accordance with 10 CFR 50.72(b)(2)(xi); 'Any event or situation, related to the health and safety of the public or onsite personnel, or protection of the environment, for which a news release is planned or notification to other government agencies has been or will be made."
.


General Information or Other
Event Number: 44031
Rep Org: WISCONSIN RADIATION PROTECTION
Licensee: MARSHFIELD CLINIC MINOCQUA CENTER
Region: 3
City: MINOCQUA   State: WI
County:
License #: 141-1162-01
Agreement: Y
Docket:
NRC Notified By: LEONA DEKOCK
HQ OPS Officer: PETE SNYDER
Notification Date: 03/05/2008
Notification Time: 14:53 [ET]
Event Date: 01/10/2008
Event Time: 00:00 [CST]
Last Update Date: 03/05/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
PATTY PELKE (R3)
MICHELE BURGESS (FSME)
ILTAB (e-mail)
Event Text
AGREEMENT STATE REPORT - LOST IODINE-125 BRACHYTHERAPY SEEDS

"A permanent prostate seed implant was performed on 12/21/07. Following this case there were 18 unused seeds remaining. Unused seeds are kept in the original shielded container provided by the vendor and stored in the nuclear medicine hot lab until returned by the Radiation Safety Officer (RSO) to the vendor for ultimate storage and disposal. Unused seeds are normally returned once each quarter by the RSO.

"In this case, however, the nuclear medicine technologist transferred the 18 seeds from the shielded container to a lead-lined radioactive waster bin for the storage of dry-solid active waste such as gloves, absorbent pads, etc. potentially contaminated with Tc-99m. This waste bin is not used for medical waste such as syringes, sharps, etc.

"The dry-solid radioactive waste bins are held for decay-in-storage. Based on the preliminary information and a review of the radioactive waste disposal log, this particular bag was surveyed and disposed of on either 1/10/08 or 2/6/08. Since they use two bins and hold for radioactive decay until the other is full, it is not clear at this time as to which bag was disposed in the regular trash. Discovery of the lost material was through inquiries by the RSO concerning how many unused seeds were available this quarter for return. If the seeds were disposed of in the regular trash on 1/10/08, the activity lost would be 5.03 milliCuries; if disposed of in the regular trash on 2/6/08, the activity lost would be 3.68 milliCuries.

"The possible disposition of the licensed radioactive material at this time is the landfill. A detailed written description of the incident will be submitted within 30 days.

"The State of Wisconsin plans to investigate this incident on an upcoming inspection."

Wisconsin Event Report ID: WI080004

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


General Information or Other
Event Number: 46277
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: SAINT JOHN MEDICAL CENTER
Region: 4
City: TULSA   State: OK
County:
License #: OK-00376-02
Agreement: Y
Docket:
NRC Notified By: MORGEN BUCKNER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 09/24/2010
Notification Time: 12:25 [ET]
Event Date: 01/10/2008
Event Time: 00:00 [CDT]
Last Update Date: 09/24/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JACK WHITTEN (R4DO)
ANGELA MCINTOSH (FSME)
Event Text
AGREEMENT STATE REPORT - MEDICAL MISADMINISTRATION

The following report was submitted via e-mail:

"On January 16, 2008, Saint John Medical Center (SJMC) Lic. # OK-00376-02, of Tulsa, OK notified the Oklahoma Department of Environmental Quality (ODEQ) that on January 10, 2008 a patient had been administered a dose of I-131 that differed from the intended dose by greater than 20%. The intended dose was 100 mCi. The administered dose was 25 mCi. The misadministration occurred because the 100 mCi dose provided by Nuclear RX, PC (NRX) Lic. # OK-31035-01MD of Tulsa, OK was divided among three capsules. Two capsules contained 25 mCi, while the third contained 50 mCi I-131. The bottle received by SJMC was opaque and stated that it contained one capsule of 309 mCi because of a software error at NRX. When the dose was administered to the patient, one capsule was dispensed from the bottle, while the other two stuck in the bottom of the bottle. The presumed empty bottle was then repackaged and shipped back to NRX where it was discovered that two capsules remained in the bottle. It was determined that the capsules contained a total of 75 mCi I-131. The capsules were not discovered before shipping because the tech at SJMC errantly surveyed the package before placing the bottle inside. Corrective actions by SJMC involve surveying the bottle prior to returning it to the transport shielding, refresher training on transport requirements in 49 CFR, and determining the transport index (TI) by survey outside of the hot lab. Corrective actions by NRX included contacting the software developer for an update that would ensure that all shipments are accurately labeled. NRX also agreed to write the number of capsules contained in each bottle on the lid of the bottle.

"Due to an oversight, this event was not reported at the time it was received by ODEQ."

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.