EVENT NUMBERS
43876438774387844189

Power Reactor
Event Number: 43876
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: RAY BUZARD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 12/31/2007
Notification Time: 13:38 [ET]
Event Date: 12/31/2007
Event Time: 08:40 [MST]
Last Update Date: 12/31/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
RYAN LANTZ (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
DEATH OF AN EMPLOYEE OUTSIDE THE PROTECTED AREA

"The following event description is based on information currently available. If through subsequent reviews of this event, additional information is identified that is pertinent to this event or alters the information being provided at this time, a follow-up notification will be made via the ENS or under the reporting requirements of 10CFR50.73.

"At approximately 06:40 MST on December 31, 2007, at the water reclamation facility for the Palo Verde Nuclear Generating Station, an employee died. The death was not related to activities impacting or related to the safety of the public or other onsite personnel. Specifically, an individual collapsed and was promptly examined by a Palo Verde Emergency Medical Technician (EMT). An air evacuation was ordered however, prior to air evacuation the individual expired. The death does not appear to be work-related nor the result of an accident.

"The individual was outside of the Radiological Controlled Area and no radioactive material or contamination was involved.

"Palo Verde has not observed any heightened public or media concern as a result of the death. Since the death is apparently unrelated to Palo Verde's industrial or radiological health and safety, no news release is planned.

"The individual's name has not yet been released, pending notification of next-of-kin.

"The Arizona Division of Occupational Safety and Health was notified of the death at 0840 MST.

"The Maricopa County Sheriff's Office is conducting a routine investigation into the death."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 43877
Facility: TURKEY POINT
Region: 2     State: FL
Unit: [] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: MICHAEL COEN
HQ OPS Officer: JEFF ROTTON
Notification Date: 01/01/2008
Notification Time: 01:15 [ET]
Event Date: 12/31/2007
Event Time: 21:10 [EST]
Last Update Date: 01/01/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
SCOTT SHAEFFER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
4 N Y 100 Power Operation 100 Power Operation
Event Text
ERDADS FAILURE FOR SEVENTY MINUTES

"This is an eight hour non-emergency notification to the NRCOC due to a major loss of emergency assessment capability (10CFR50.72(b)(3)(xiii)).

"At approximately 2110 on 12/31/07 it was discovered that the Unit 4 ERDADS [Emergency Response Data Acquisition Display System] failed. This impacted the ability of the ERDS link to transmit valid data. The U4 ERDADS was restored at 2220 on 12/31/07. The system was unavailable for 70 minutes. The ERDS link to the NRC and U4 ERDADS are now fully Operable.

"U4 ERDADS failed due to corrupted shared memory on both PEDS (Plant and Environmental Data System). The PEDS units were de-energized to clear the corrupted shared memory and then reset successfully."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 43878
Facility: BROWNS FERRY
Region: 2     State: AL
Unit: [] [] [3]
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: JOE BENNETT
HQ OPS Officer: JOE O'HARA
Notification Date: 01/01/2008
Notification Time: 01:58 [ET]
Event Date: 12/31/2007
Event Time: 21:40 [CST]
Last Update Date: 01/01/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
SCOTT SHAEFFER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
UNIT 3 AUTOMATIC SCRAM DUE TO MAIN GENERATOR LOAD REJECT SIGNAL

"On 12/31/07 at 2140 the Unit 3 reactor scrammed due to turbine generator load reject signal on the Main Generator. The cause of the load reject signal is unknown and the investigation is continuing. All systems responded as expected to the load reject signal. Six Main Steam Relief valves (MSRVs) opened momentarily and then reclosed. Subsequently, reactor pressure was automatically controlled by the Main Turbine Bypass valves. No Emergency Core Cooling System (ECCS), nor Reactor Core Isolation Cooling (RCIC) reactor water level initiation setpoints were reached, and reactor water level is being automatically controlled by the Feedwater system. This report is being made as required by 10CFR 50.72(b)(2) due to the actuation of the Reactor protection System.

"Refer to BFN PER number 135878."

All control rods fully inserted into the core, and all safety systems are operable. PCIS group isolations were received for groups 2, 3, 6, and 8. There were no grid abnormalities at the time of the load reject, and the event had no effect on Unit 1 or 2.

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 44189
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: ACCURATE NDE AND INSPECTION LLC
Region: 4
City:   State: LA
County:
License #: LA-10207-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JASON KOZAL
Notification Date: 05/06/2008
Notification Time: 11:42 [ET]
Event Date: 12/31/2007
Event Time: 00:00 [CDT]
Last Update Date: 05/06/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
GREG PICK (R4)
MICHELE BURGESS (FSME)
Event Text
LOUISIANA AGREEMENT STATE REPORT - PERSONNEL OVEREXPOSURE

The State provided the following information via facsimile:

"An overexposure was discovered during a routine compliance inspection of Accurate NDE & Inspection on March 25, 2008. This overexposure was not reported to the Louisiana Department of Environmental Quality. An industrial radiographer received a dose of 7819 mrem for the calendar year 2007. The licensee has been cited for the overexposure and for not reporting the overexposure. This overexposure is being investigated by the LA Department of Environmental Quality."

LA Report ID No.: LA08009