Skip to main content

Event Notification Report for December 23, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/22/2007 - 12/23/2007

EVENT NUMBERS
43864

Fuel Cycle Facility
Event Number: 43864
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 2     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: BILLY WALLACE
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 12/23/2007
Notification Time: 19:02 [ET]
Event Date: 12/23/2007
Event Time: 03:58 [CST]
Last Update Date: 12/23/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(1) - UNPLANNED CONTAMINATION
Person (Organization):
SCOTT SHAEFFER (R2)
ABY MOHSENI (FSME)
Event Text
SMALL UF6 PROCESS LEAK

"On 12/23/2007 at 0358 the C-333 unit 3 cell 1 PGLD (process gas leak detection) head (YE-5) at stage 5 actuated. Along with the PGLD actuation a seal alarm and a vibration alarm on stage 7 were received. A nearby operator on the cell floor responded to the alarm and observed a small UF6 release from the stage 7A seal cavity. To stop the release the cell was immediately shut down from the ACR which lowered the cell's pressure to below atmospheric pressure. The exact amount of material released has not been determined. Checks by health physics personnel found the actual amount of UF6 released was not significant and resulted in a relatively small area of contamination on the end of the compressor near the seal that failed and on the floor immediately around the end of the compressor.

"The actuated PGLD head is a Q safety system component. At the time of the incident the cell was operating in a mode which required the system to be operational. This is being reported based on SAR 6.9 Table 1, J2 (unplanned actuation of a Q safety system) and 10 CFR 76.120(c)(1)(i) (unplanned contamination event).

"The NRC Resident Inspector has been notified of this event.

"PGLD Problem Report Nos. ATRC-07-3433; PGLD Event Report No. PAD-2007-022; NRC Event Number 43864"