Event Notification Report for December 19, 2007
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/18/2007 - 12/19/2007
Other Nuclear Material
Event Number: 43862
Rep Org: KEY TECH
Licensee: KEY TECH
Region: 1
City: KEYPORT State: NJ
County:
License #: 29-19282-01
Agreement: N
Docket:
NRC Notified By: FONG CHEN
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: KEY TECH
Region: 1
City: KEYPORT State: NJ
County:
License #: 29-19282-01
Agreement: N
Docket:
NRC Notified By: FONG CHEN
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 12/21/2007
Notification Time: 16:07 [ET]
Event Date: 12/19/2007
Event Time: 10:00 [EST]
Last Update Date: 12/27/2007
Notification Time: 16:07 [ET]
Event Date: 12/19/2007
Event Time: 10:00 [EST]
Last Update Date: 12/27/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
PAMELA HENDERSON (R1)
ABY MOHSENI (FSME)
PAMELA HENDERSON (R1)
ABY MOHSENI (FSME)
DAMAGED MOISTURE DENSITY GAUGE
The Troxler moisture density gauge was being used at a construction site in Newark, New Jersey near Jackson Street. The gauge was not in use and the source rod was in the safety position when a roller rolled over part of the gauge. The area around the gauge was cordoned off until the RSO performed radiation surveys and performed a wipe test. The survey indicated no contamination or leakage. The wipe test was shipped to Troxler and verified no radioactive material leakage. The gauge is currently in the licensee's gauge storage room awaiting disposition.
Troxler Moisture Density gauge Model 3440
Serial Number 16356
One Cs-137 source (typically 8 milliCuries)
* * * UPDATE FROM FONG CHEN TO HOWIE CROUCH @ 1430 EST ON 12/27/07 VIA TELEPHONE * * *
The licensee wanted to clarify some statements made in the original report. The gauge was in use at the time of the incident with the source rod in the testing position. After the gauge was hit, the licensee was able to retract the source into the shielded (safe) position. A leak test swipe was performed and the swipe was overnighted to Troxler. Troxler reported that sample results were negative for leakage.
Notified R1DO (Perry) and FSME (Wassler).
The Troxler moisture density gauge was being used at a construction site in Newark, New Jersey near Jackson Street. The gauge was not in use and the source rod was in the safety position when a roller rolled over part of the gauge. The area around the gauge was cordoned off until the RSO performed radiation surveys and performed a wipe test. The survey indicated no contamination or leakage. The wipe test was shipped to Troxler and verified no radioactive material leakage. The gauge is currently in the licensee's gauge storage room awaiting disposition.
Troxler Moisture Density gauge Model 3440
Serial Number 16356
One Cs-137 source (typically 8 milliCuries)
* * * UPDATE FROM FONG CHEN TO HOWIE CROUCH @ 1430 EST ON 12/27/07 VIA TELEPHONE * * *
The licensee wanted to clarify some statements made in the original report. The gauge was in use at the time of the incident with the source rod in the testing position. After the gauge was hit, the licensee was able to retract the source into the shielded (safe) position. A leak test swipe was performed and the swipe was overnighted to Troxler. Troxler reported that sample results were negative for leakage.
Notified R1DO (Perry) and FSME (Wassler).
Power Reactor
Event Number: 43854
Facility: OYSTER CREEK
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: DAVE GREINER
HQ OPS Officer: HOWIE CROUCH
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: DAVE GREINER
HQ OPS Officer: HOWIE CROUCH
Notification Date: 12/19/2007
Notification Time: 14:57 [ET]
Event Date: 12/19/2007
Event Time: 11:45 [EST]
Last Update Date: 12/19/2007
Notification Time: 14:57 [ET]
Event Date: 12/19/2007
Event Time: 11:45 [EST]
Last Update Date: 12/19/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JAMES TRAPP (R1)
JAMES TRAPP (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 55 | Power Operation | 0 | Hot Shutdown |
MANUAL REACTOR SCRAM DUE TO LOWERING REACTOR LEVEL
At 1145 EST, operators inserted a manual reactor scram due to lowering reactor water level after the 'A' main feedwater pump tripped. Prior to the scram, the plant was operating at reduced power due to removing the 'B' main feedwater pump from service for planned maintenance. Reactor water level was at 155" when the scram was initiated and lowered to 100" during the transient. Currently, reactor water level is at the normal operating band and is being maintained by the feedwater system.
After the scram, all safety systems functioned as expected. There were no system isolations due to the transient. Electrical power is being provided by normal offsite sources via the startup transformer. Decay heat is being removed via the normal path through bypasses to the main condensers.
Additionally, the licensee made an offsite notification to the New Jersey Department of Environmental Protection due to approximately 300 dead or distressed fish in the discharge canal.
The licensee has notified the NRC Resident Inspector.
At 1145 EST, operators inserted a manual reactor scram due to lowering reactor water level after the 'A' main feedwater pump tripped. Prior to the scram, the plant was operating at reduced power due to removing the 'B' main feedwater pump from service for planned maintenance. Reactor water level was at 155" when the scram was initiated and lowered to 100" during the transient. Currently, reactor water level is at the normal operating band and is being maintained by the feedwater system.
After the scram, all safety systems functioned as expected. There were no system isolations due to the transient. Electrical power is being provided by normal offsite sources via the startup transformer. Decay heat is being removed via the normal path through bypasses to the main condensers.
Additionally, the licensee made an offsite notification to the New Jersey Department of Environmental Protection due to approximately 300 dead or distressed fish in the discharge canal.
The licensee has notified the NRC Resident Inspector.
General Information or Other
Event Number: 43994
Rep Org: COLORADO DEPT OF HEALTH
Licensee: KLEINFELDER, INC.
Region: 4
City: PUEBLO State: CO
County:
License #: 958-01
Agreement: Y
Docket:
NRC Notified By: JAMES H. GRICE III
HQ OPS Officer: STEVE SANDIN
Licensee: KLEINFELDER, INC.
Region: 4
City: PUEBLO State: CO
County:
License #: 958-01
Agreement: Y
Docket:
NRC Notified By: JAMES H. GRICE III
HQ OPS Officer: STEVE SANDIN
Notification Date: 02/19/2008
Notification Time: 17:56 [ET]
Event Date: 12/19/2007
Event Time: 16:00 [MST]
Last Update Date: 02/19/2008
Notification Time: 17:56 [ET]
Event Date: 12/19/2007
Event Time: 16:00 [MST]
Last Update Date: 02/19/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GEOFFREY MILLER (R4)
ROBERT LEWIS (FSME)
GEOFFREY MILLER (R4)
ROBERT LEWIS (FSME)
AGREEMENT STATE REPORT INVOLVING A DAMAGED CPN PORTABLE GAUGE
The following report was received via email:
"This is the initial notification for an incident that was reported to this Department on 12/19/2007 at approximately 4:00PM. At that time the Department was notified by telephone of an accident involving a CPN model MC1 DR portable gauge. The gauge is owned and operated by Kleinfelder, Inc., Colorado Radioactive Materials License Number 958-01. The incident occurred at a temporary jobsite just outside of Pueblo, Colorado. The individual notifying the Department was . . . the company RSO. The licensee reported that while at the jobsite the operator backed his vehicle over the gauge. At the time of the accident, the Cs-137 source was in its shielded position. The result of the accident was that the handle/source rod was snapped off above the gauge case approximately 6 inches from the top of the handle. The source remained in the shielded position and the body of the gauge remained intact with no apparent damage. The gauge was inspected by Department personnel on 02/04/2008 and was found to be in the condition previously described by the RSO. The department had directed the Licensee to leak test the gauge at the time the report was initially made and the results are pending. Once the leak test results are received by the Department the licensee will be directed to provide details on repair or disposal of the gauge. No other details are available at this time."
The following report was received via email:
"This is the initial notification for an incident that was reported to this Department on 12/19/2007 at approximately 4:00PM. At that time the Department was notified by telephone of an accident involving a CPN model MC1 DR portable gauge. The gauge is owned and operated by Kleinfelder, Inc., Colorado Radioactive Materials License Number 958-01. The incident occurred at a temporary jobsite just outside of Pueblo, Colorado. The individual notifying the Department was . . . the company RSO. The licensee reported that while at the jobsite the operator backed his vehicle over the gauge. At the time of the accident, the Cs-137 source was in its shielded position. The result of the accident was that the handle/source rod was snapped off above the gauge case approximately 6 inches from the top of the handle. The source remained in the shielded position and the body of the gauge remained intact with no apparent damage. The gauge was inspected by Department personnel on 02/04/2008 and was found to be in the condition previously described by the RSO. The department had directed the Licensee to leak test the gauge at the time the report was initially made and the results are pending. Once the leak test results are received by the Department the licensee will be directed to provide details on repair or disposal of the gauge. No other details are available at this time."