Event Notification Report for November 05, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/04/2007 - 11/05/2007

EVENT NUMBERS
4377143772

Power Reactor
Event Number: 43771
Facility: COLUMBIA GENERATING STATION
Region: 4     State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: STEPHEN MAZURKIEWICZ
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/05/2007
Notification Time: 14:11 [ET]
Event Date: 11/05/2007
Event Time: 00:00 [PST]
Last Update Date: 11/05/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
BLAIR SPITZBERG (R4)
GREG MORELL (FSME)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
TRANSPORTATION OF RADIOACTIVE MATERIAL WITHOUT PROPER LABELING

"Pursuant to 10 CFR 50.72(b)(2)(xi), Energy Northwest hereby informs the Nuclear Regulatory Commission (NRC) of an intent to report a undeclared shipment of hazardous material to the Department of Transportation (DOT).

"Energy Northwest recently discovered that on January 23, 2007 an NCS Model LMP-10 Freon monitor, containing a 300 mCi Tritium source, was transferred to NCS Corporation for calibration without designating the shipment as Radioactive Material, Excepted Package, Limited Quantity of Material, 7, UN2910 as required by 49 CFR 173.421(a). The monitor was shipped from Richland, WA on January 23, 2007 via UPS and received in Columbus, OH on January 24, 2007. The return shipment of the instrument to Energy Northwest was received on February 12, 2007 and was designated as containing radioactive material.

"There were no consequences associated with this incident and the potential for radioactive exposure of any individual as a result of this shipment was negligible."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 43772
Facility: THREE MILE ISLAND
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: JAMES PAULES
HQ OPS Officer: JASON KOZAL
Notification Date: 11/05/2007
Notification Time: 21:22 [ET]
Event Date: 11/05/2007
Event Time: 16:49 [EST]
Last Update Date: 11/06/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
MARIE MILLER (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling Shutdown 0 Refueling Shutdown
Event Text
SPDS OUT OF SERVICE FOR PLANNED MAINTENANCE

"At 16:49 hours, on 11/05 the Unit 1 SPDS and ERDS systems were removed from service to support restoration activities from a planned maintenance outage on the power supply. The duration of work is expected to be approximately 10 hours. (Scheduled for completion at 03:00 on 11/06/2007). During this time, Control Room indications and alternate methods will be available.

"Since the SPDS computer system will be unavailable for greater than 8 hours, this is considered a Loss of Emergency Assessment Capability and reportable under 10 CFR 50.72(b)(3)(xiii).

"A follow-up notification will be made to the NRC after the SPDS and ERDS system are returned to service."

The licensee will notify the NRC Resident Inspector.

* * * UPDATE AT 0315 ON 11/6/07 FROM J. PAULES TO P. SNYDER * * *

At 0314 on 11/6/07 the SPDS and ERDS systems were returned to service.

The licensee will notify the NRC Resident Inspector. Notified R1DO (M. Miller).