Event Number: 43768
Facility: FERMI
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: P. FALLON
HQ OPS Officer: JEFF ROTTON
Notification Date: 11/03/2007
Notification Time: 17:26 [ET]
Event Date: 11/03/2007
Event Time: 17:22 [EDT]
Last Update Date: 11/08/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JOHN MADERA (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
LOSS OF SPDS AND ERDS DUE TO PLANNED MAINTENANCE

"At 1722 hours, on 11/3/2007, the SPDS and ERDS system was removed from service to support activities for a planned maintenance outage on the UPS vital bus power supply. The duration of work is expected to be approximately 48 hours. During this time, Control Room indications and alternate methods will be available. Since the SPDS computer system will he unavailable for greater than 8 hours, this is considered a Loss of Emergency Assessment Capability and reportable under 10CFR50.72(b)(3)(xiii). The licensee will notify the NRC Resident Inspector."

* * * UPDATE AT 1715 ON 11/7/2007 FROM SUE REITH TO MARK ABRAMOVITZ * * *

"Maintenance activities are continuing on the power supply for the SPDS and ERDS systems. Current estimate will restore the computer systems by 2000 on 11/08/07. An update will be provided once SPDS and ERDS are restored." R3DO (M. Phillips) notified.

The licensee notified the NRC Resident Inspector.

* * * UPDATE AT 1234 ON 11/8/2007 FROM DAVID HEMMELE TO MARK ABRAMOVITZ * * *

"Planned work which resulted in the removal from service of SPDS and ERDS has been completed. SPDS and ERDS have been restored to service as of 1115 11/8/2007."

The licensee notified the NRC Resident Inspector.

Notified the R3DO (Phillips).


Other Nuclear Material
Event Number: 43769
Rep Org: KAKIVIK ASSET MANAGEMENT
Licensee: KAKIVIK ASSET MANAGEMENT
Region: 4
City: FAIRBANKS   State: AK
County:
License #: 50.27667-01
Agreement: N
Docket:
NRC Notified By: PAUL CASEY
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 11/04/2007
Notification Time: 16:10 [ET]
Event Date: 11/03/2007
Event Time: 15:00 [YDT]
Last Update Date: 11/04/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
DALE POWERS (R4)
JANET SCHLUETER (FSME)
Event Text
RADIOGRAPHY CAMERA SOURCE FAILS TO FULLY RETRACT INTO CAMERA

The licensee was using a radiography camera on the Alaska pipeline approximately 50 miles North of Fairbanks (near pump station 7). The temperature was approximately 5 to 8 degrees F. Moisture entered into the locking mechanism causing the latch to trip prematurely i.e. the source was not fully retracted into the camera. The RSO took the latching mechanism apart and fully retracted the source. The RSO and assistant each received a dose of 30 millirem during this repair.

Radiography camera: Industrial Nuclear Corporation model IR-100
Source: 72 Curie Ir-192