Event Notification Report for October 28, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/27/2007 - 10/28/2007

EVENT NUMBERS
4375243753

Power Reactor
Event Number: 43752
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: DAVE RICHARDSON
HQ OPS Officer: JEFF ROTTON
Notification Date: 10/28/2007
Notification Time: 03:24 [ET]
Event Date: 10/28/2007
Event Time: 00:59 [EDT]
Last Update Date: 10/28/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOHN CARUSO (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Shutdown
Event Text
MANUAL SCRAM DUE TO LOWERING INTAKE LEVEL

"High winds (in excess of 40 MPH) resulted in significant debris at the plant intake. Traveling screens had been placed in 'Fast' speed and continuous wash on the previous shift in anticipation of predicted high wind conditions. As the debris entered the intake, high traveling screen differential pressure and lowering intake level prompted the operating crew to enter the appropriate Abnormal Operating Procedure (AOP).

"Efforts to manually clean the screens were ineffective, and at 0059 hours, the crew inserted a manual scram as directed by procedure at 240 foot intake level.

"On scram, as expected, reactor vessel level lowered to the low level scram setpoint (177 inches above top of active fuel). At this point, as expected, an automatic Reactor Protection System (RPS) actuation, and a Group 2 Primary Containment Isolation System (PCIS) isolation occurred with no anomalies noted.

"During plant cooldown reactor level lowered to 177 inches above TAF. This resulted in a valid RPS actuation and a PCIS Group 2 isolation signal. All systems responded as expected.

"Operators were able to maintain reactor vessel level above the actuation setpoint for High Pressure Coolant Injection (HPCI) and Reactor Core Isolation Cooling (RCIC) systems, and these systems were not required to operate.

"The cause of the failure of the traveling screens to maintain intake level is under investigation.

"All control rods are fully inserted and the plant is stable in Mode 3, Hot Shutdown."

Decay heat is being removed via the turbine bypass valves to the main condenser. No SRVs lifted during the transient. The plant is in a normal shutdown electric plant lineup.

The licensee notified the NRC Resident Inspector and the New York Public Service Commission.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 43753
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BERNIE LITKETT
HQ OPS Officer: JEFF ROTTON
Notification Date: 10/29/2007
Notification Time: 02:12 [ET]
Event Date: 10/28/2007
Event Time: 22:03 [EDT]
Last Update Date: 11/13/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOHN CARUSO (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
REFUEL FLOOR EXHAUST HI-HI RADIATION ALARMS DURING REACTOR REASSEMBLY

"On 10/28/07 at 2203 in Operational Condition 5, two of three Refuel Floor Exhaust Radiation Monitors actuated on HI-HI Radiation during the Moisture Separator lift for Reactor Pressure Vessel Reassembly. Reactor Building Ventilation was procedurally secured at the time of the actuation to minimize the potential for airborne contamination. The cause of the elevated radiation levels at the Refuel Floor Exhaust Radiation Monitors is currently attributed to the lifting of the Moisture Separator closer to the surface of the water to obtain an unobstructed underwater path to the Reactor Pressure Vessel. The resulting ESF signal yielded an automatic start of the 'A' and 'D' Station Service Water Pumps, the Filtration Recirculation and Ventilation System, and load-shed of non-1E breaker loads. All systems responded as expected. Systems and components actuated by the condition have been restored to a normal stand-by alignment as required. No other systems were affected and the plant is stable in Operational Condition 5."

The licensee will notify the NRC Resident Inspector. The licensee notified the Lower Alloways Creek Township.

* * * RETRACTION AT 1554 ON 11/13/2007 FROM MICHAEL REED TO MARK ABRAMOVITZ * * *

"Follow up investigation has revealed that the initiation of the signals was the result of radiation levels outside of the Refuel Floor Exhaust duct, and not from the in-duct activity. This would not be considered the parameter satisfying the requirements for initiation of the safety function of the system. The actual plant condition that satisfies the requirements for initiation of the safety function of the system is to detect conditions and initiate protective actions due to a release of steam or radioactive material internal to the duct that could result in the release of fission products to the environment. As a result, this is not considered a 'valid actuation' and is being retracted. Also, upon review of the refuel floor camera system, the reason for the HI-HI actuation was that during the Moisture Separator lift, the Moisture Separator broke the surface of the water by approximately 24 inches. This caused the radiation monitors to alarm on radiation shine from the moisture separator rather than airborne activity in the exhaust duct.

"This notification also provides telephone notification of an invalid actuation other than actuation of the reactor protection system instead of submitting a written LER
1. This is not considered an LER
2. This report is being made under 10 CFR 50.73(a)(2)(iv)(A).
3. The resulting ESF signal yielded an automatic start of the 'A' and 'D' Station Service Water Pumps, the Filtration, Recirculation and Ventilation System (FRVS), and load-shed of non-1E breaker loads: all systems responded as expected. This was a complete actuation. All required systems started and functioned successfully."

The licensee notified the NRC Resident Inspector.

Notified the R1DO (Holody).