Skip to main content

Event Notification Report for October 25, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/24/2007 - 10/25/2007

EVENT NUMBERS
4375043745437584374847008

Power Reactor
Event Number: 43750
Facility: POINT BEACH
Region: 3     State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: ROBERT BROCK
HQ OPS Officer: JASON KOZAL
Notification Date: 10/26/2007
Notification Time: 14:19 [ET]
Event Date: 10/25/2007
Event Time: 19:30 [CDT]
Last Update Date: 10/26/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
DAVID HILLS (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
BOTH LOW TEMPERATURE OVERPRESSURE PROTECTION SYSTEMS OUT OF SERVICE

"This 8 hour report is being made pursuant to 10 CFR 50.72(b)(3)(v). On 10/25/2007 at 1930 CDT Point Beach Nuclear Plant (PBNP) Unit 1 and Unit 2 low temperature overpressure protection systems (LTOP) were declared inoperable as a result of the determination that the current LTOP actuation setpoint was non-conservative based on updated calculations. Specifically,

"1) The mass input from the Safety Injection Pumps has significantly increased based on the use of a Point Beach Nuclear Plant specific system flow model.

"2) The setpoint calculation does not consider instrument delay times during (PORV) Pilot Operated Relief Valve actuation.

"3) The updated Calculation changes instrument uncertainties.

"LCO 3.4.12 for the LTOP system is not applicable at this time for either unit (both units in Mode 1/100% power). LCO 3.4.12 is only applicable in Mode 5, Mode 6 when the reactor vessel head is on, and Mode 4 when any cold leg temperature is at or below the temperature specified in the Pressure Temperature Limits Report (270 deg F).

"Changes to operating procedures to delineate operation of reactor coolant pumps and charging pumps during low temperature conditions are in progress. Implementation of these procedure changes will permit LTOP to be returned to service."

The licensee stated that this issue was discovered as part of the on going calculation reconstitution initiative at the plant.

The licensee notified the NRC Resident Inspector.

* * * UPDATE PROVIDED BY RYAN RODE TO JASON KOZAL AT 2135 ON 10/26/07 * * *

"The following is an update to the 8 hr report made to the NRC via EN#43750:

"On 10/26/07 at 17:51 procedure changes which identify requirements for operation of reactor coolant pumps and charging pumps during low temperature conditions have been made. These procedures provide the guidance required to ensure that the current LTOP setpoints remain conservative. Based on the issuance of these procedures with the required guidance, LTOP is returned to service for both Unit-1 and Unit-2."

The licensee notified the NRC Resident Inspector. Notified R3DO (Hills).


General Information or Other
Event Number: 43745
Rep Org: OK DEQ RAD MANAGEMENT
Licensee: KLEINFELDER CENTRAL, INC
Region: 4
City: TULSA   State: OK
County:
License #: OK-27597-02
Agreement: Y
Docket:
NRC Notified By: KEVIN SAMPSON
HQ OPS Officer: JOHN KNOKE
Notification Date: 10/25/2007
Notification Time: 11:20 [ET]
Event Date: 10/25/2007
Event Time: 10:00 [CDT]
Last Update Date: 10/25/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
GREG MORELL (FSME)
ILTAB EMAIL
Event Text
AGREEMENT STATE REPORT - STOLEN SOIL DENSITY GAUGE

State called indicating licensee reported a Humboldt soil density gauge, Model 5001B (s/n 2978) was stolen from the back of an employee's pickup truck sometime during the night of 10/24/07. The gauge was chained down (but was cut) while parked at the employee's personal residence. The source activity is 44 mCi of Am-241/Be and 11 mCi of Cs-137. A police report was filed with the Tulsa police department, Report # 2007-074-103.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


General Information or Other
Event Number: 43758
Rep Org: MISSISSIPPI DIV OF RAD HEALTH
Licensee: NUMEDRX
Region: 4
City: JACKSON   State: MS
County:
License #: MS-1006-01
Agreement: Y
Docket:
NRC Notified By: JEFF ALGEE
HQ OPS Officer: JASON KOZAL
Notification Date: 10/30/2007
Notification Time: 11:48 [ET]
Event Date: 10/25/2007
Event Time: 08:00 [CDT]
Last Update Date: 10/30/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
DALE POWERS (R4)
MICHELE BURGESS (FSME)
Event Text
AGREEMENT STATE - ACCIDENT INVOLVING TRUCK CARRYING RADIOPHARMACEUTICALS

The State provided the following information via email:

"DRH notified by NuMedRx Nuclear Pharmacy RSO that one of their delivery vehicles had been involved in an accident on Highway 49 North at the Highway 16 intersection. Apparently, the vehicle was struck by a school bus while it was en route to making a delivery to a Greenville, MS facility. No students were on the bus at the time of the collision. Apparently, law enforcement personnel did not realize the vehicle was transporting radioactive materials and no notifications were made to MEMA. DRH was not notified until after the vehicle was removed by the wrecker service. DRH responded to the wrecker service facility to survey and retrieve the transport container. The transport container was not ejected from the vehicle; however, the package was turned over and was not secured by the straps anymore. The package was labeled 'Yellow II' and still secured by the tamper seal. No leakage was detected [levels were 0.4 mR/hr at the surface of transport container] and radioactive doses/package were returned to RSO at the Jackson, MS nuclear pharmacy."

The delivery vehicle was carrying Thallium-201 and Technetium-99m totaling 13 millicuries.

Mississippi report number: MS 07007


General Information or Other
Event Number: 43748
Rep Org: ENERTECH
Licensee: ENERTECH
Region: 4
City: BREA   State: CA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: KEVIN McKOWN
HQ OPS Officer: STEVE SANDIN
Notification Date: 10/25/2007
Notification Time: 19:10 [ET]
Event Date: 10/25/2007
Event Time: 00:00 [PDT]
Last Update Date: 12/21/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
CHUCK CAIN (R4)
ROBERT HAAG (R2)
VERN HODGE (email) (NRR)
Event Text
POTENTIAL 10CFR PART 21 REPORTABLE CONDITION FOR ENERTECH CARTRIDGE SOLENOID VALVE

The following notification was received via fax:

"This submittal provides initial notification to your office that we have opened an evaluation for a potential reportable condition under 10CFR Part 21. Based on technical data provided by the San Onofre Power Plant, two (2) Enertech normally energized, normally open, cartridge solenoid valves, part number C9113S, installed on PME dump valves have not operated within the closure time design parameters. Upon investigation SCE determined higher than expected levels of contamination, internal oxidation and pitting collectively effected the valves response time. This valve was introduced to the industry in Dec 2004. Enertech is working closely with plant personnel to determine the cause of this condition, determine a resolution, and prepare a formal Evaluation Report within the next 50 days. If at any time during the evaluation process, a defect is discovered, we will provide an amended notification to this communication.

"No other Power Plants have reported similar problems to Enertech. The solenoid valve under evaluation has multiple safety related applications. The following plants will be contacted if a reportable condition exists: SCE, STP, KHNP, Entergy (Waterford), and Dominion (Surry)."

* * * UPDATE FROM ENERTECH (MCKOWN) TO HUFFMAN VIA FAX AT 1845 EST ON 12/21/07 * * *

"Our 60 day evaluation has concluded that a 10 CFR Part 21 reportable condition does not exist regarding this issue. We have reached this conclusion on the following basis:

"Our evaluation could not establish our valve has a defect, a deviation, or a departure from a technical requirement.

"Enertech worked with SCE plant personnel to determine the cause of the 2 solenoid valves condition. The root cause of the failure of the inlet solenoid valve cartridges to operate was corrosion buildup at poppet flow orifice.

"Enertech was unable to duplicate the SONGS Unit 3 experience using valves that had been exposed to trapped hydraulic fluid with high water content for periods of 20-26 months. We inspected and tested valves in our inventory and valves previously shipped to other sites, resulting in no observed corrosion. Concluding the event did not have a common mode failure.

"The solenoid valve cartridge has been used by a significant number of nuclear utilities, including SONGS Unit 2, without identifying similar situations to those experienced at SONGS Unit 3."

R4DO (Pruett), R2DO (Shaeffer) and the Part 21 Coordinators (Hodge and Thorp via e-mail) have been notified


Agreement State
Event Number: 47008
Rep Org: NEW YORK STATE DEPT. OF HEALTH
Licensee: NY HOSPITAL
Region: 1
City: NEW YORK   State: NY
County:
License #:
Agreement: Y
Docket:
NRC Notified By: ROBERT SNYDER
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 07/01/2011
Notification Time: 11:19 [ET]
Event Date: 10/25/2007
Event Time: 00:00 [EDT]
Last Update Date: 07/01/2011
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BLAKE WELLING (R1DO)
DEBORAH JACKSON (FSME)
Event Text
AGREEMENT STATE REPORT - MEDICAL MISADMINISTRATION DURING GAMMA KNIFE THERAPY

The following report was received via fax:

"On 10/25/2007, [the New York State Department of Health] received a call from a radiation oncology manager to report a therapy misadministration involving a gamma knife due to a machine malfunction, couch failure. The physicist and the neurosurgeon had to go in and manually pull the couch out. The physicist's badge was read on an emergency basis and showed DDE of 1 mRem and SDE of 2 mRem. The neurosurgeon did not have his badge on when he went in. The facility has treated about 125 patients in 4 years with the gamma knife unit, according to field notes from the inspection done in February 2007 and is close to the 5 year service requirement. The facility had planned to treat 10 lesions in the brain but stopped after 3 lesions were treated due to couch failure. The rest of the lesions were not treated with radiation. The patient had already received whole brain irradiation and received additional chemotherapy after the gamma knife procedure.

"Service performed: couch repaired. Policy & Procedure regarding film badge use reviewed during next routine inspection. This event is closed."

New York Event: NY-11-15
New York Incident: 570

A Medical Event may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.