Event Notification Report for October 24, 2007
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
10/23/2007 - 10/24/2007
Hospital
Event Number: 43746
Rep Org: KARMANOS CANCER CENTER
Licensee: KARMANOS CANCER CENTER
Region: 3
City: DETROIT State: MI
County:
License #: 21-04127-06
Agreement: N
Docket:
NRC Notified By: JOE RAKOWSKI
HQ OPS Officer: MARK ABRAMOVITZ
Licensee: KARMANOS CANCER CENTER
Region: 3
City: DETROIT State: MI
County:
License #: 21-04127-06
Agreement: N
Docket:
NRC Notified By: JOE RAKOWSKI
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 10/25/2007
Notification Time: 11:40 [ET]
Event Date: 10/24/2007
Event Time: 14:00 [EDT]
Last Update Date: 10/26/2007
Notification Time: 11:40 [ET]
Event Date: 10/24/2007
Event Time: 14:00 [EDT]
Last Update Date: 10/26/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
10 CFR Section:
35.3045(a)(1) - DOSE <> PRESCRIBED DOSAGE
Person (Organization):
DAVID HILLS (R3)
GREG MORELL (FSME)
DAVID HILLS (R3)
GREG MORELL (FSME)
GAMMA KNIFE TREATMENT TO WRONG SIDE OF BRAIN
"On October 24, 2007, a medical event occurred at Leksel Gamma Knife facility which resulted in the total dose delivered differing from the prescribed dose by more than20%.
"1. Licensee's name: Karmanos Cancer Center.
"2. Name of prescribing physician: [DELETED]
"3. Brief description of the event:
"Due to a left - right reversal of the treatment planning MRI images, the patient's left side was targeted and treated rather than the right side. The error resulted in an 18 mm shift of isocenter across midline of the brain. The collimator diameter selected for the treatment was 18 mm, thus resulting in some overlap of the delivered 50% isodose volume with the correct intended target lesion volume. The event resulted in approximately 7% of the lesion volume receiving the prescribed dose of 18 Gy to the 50% isodose, rather than the preferred 95% of the lesion volume.
"4. Why the event occurred:
"During the pre-treatment setup and simulation MRI imaging, a 'feet first' scan technique was used with the patient positioned in the MRI scanner head first. This had the effect of reversing the axial images left to right. The standard of practice in gamma knife radiosurgery is to position the patient in the MRI scanner head first, and to use the 'head first' scan technique. The gamma knife authorized medical physicist (AMP) failed to recognize the scanning error when importing the MRI images into the Gamma Knife treatment planning computer, and subsequently registered them as head first. This resulted in the wrong side of the patient being targeted and treated, i.e. the left cerebellum was targeted and treated rather than the right cerebellar lesion.
"5. The effect on the individual who received the administration:
"To be determined.
"6. What actions have been taken or are planned to prevent recurrence:
"For all future gamma knife cases, left/right alignment of the MRI images will be inspected by the AMP by using the Leksel anterior face plate with fiducial markers visible in the MRI images. A Gamma Knife MRI protocol will be written and posted in the MRI department and in the Gamma Knife suite. The protocol will clearly indicate the patient and scan orientation required for Gamma Knife planning and delivery, which are patient on table head first, with head first scanning protocol.
"7. Certification that the licensee notified the individual, and if not, why not:
"The referring neurosurgeon will be notified this evening after he finishes with surgery."
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE AT 08:13 ON 10/26/2007 FROM GREG MORELL TO MARK ABRAMOVITZ * * *
This event has been reviewed and determined to be a reportable medical event.
"On October 24, 2007, a medical event occurred at Leksel Gamma Knife facility which resulted in the total dose delivered differing from the prescribed dose by more than20%.
"1. Licensee's name: Karmanos Cancer Center.
"2. Name of prescribing physician: [DELETED]
"3. Brief description of the event:
"Due to a left - right reversal of the treatment planning MRI images, the patient's left side was targeted and treated rather than the right side. The error resulted in an 18 mm shift of isocenter across midline of the brain. The collimator diameter selected for the treatment was 18 mm, thus resulting in some overlap of the delivered 50% isodose volume with the correct intended target lesion volume. The event resulted in approximately 7% of the lesion volume receiving the prescribed dose of 18 Gy to the 50% isodose, rather than the preferred 95% of the lesion volume.
"4. Why the event occurred:
"During the pre-treatment setup and simulation MRI imaging, a 'feet first' scan technique was used with the patient positioned in the MRI scanner head first. This had the effect of reversing the axial images left to right. The standard of practice in gamma knife radiosurgery is to position the patient in the MRI scanner head first, and to use the 'head first' scan technique. The gamma knife authorized medical physicist (AMP) failed to recognize the scanning error when importing the MRI images into the Gamma Knife treatment planning computer, and subsequently registered them as head first. This resulted in the wrong side of the patient being targeted and treated, i.e. the left cerebellum was targeted and treated rather than the right cerebellar lesion.
"5. The effect on the individual who received the administration:
"To be determined.
"6. What actions have been taken or are planned to prevent recurrence:
"For all future gamma knife cases, left/right alignment of the MRI images will be inspected by the AMP by using the Leksel anterior face plate with fiducial markers visible in the MRI images. A Gamma Knife MRI protocol will be written and posted in the MRI department and in the Gamma Knife suite. The protocol will clearly indicate the patient and scan orientation required for Gamma Knife planning and delivery, which are patient on table head first, with head first scanning protocol.
"7. Certification that the licensee notified the individual, and if not, why not:
"The referring neurosurgeon will be notified this evening after he finishes with surgery."
A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.
* * * UPDATE AT 08:13 ON 10/26/2007 FROM GREG MORELL TO MARK ABRAMOVITZ * * *
This event has been reviewed and determined to be a reportable medical event.
General Information or Other
Event Number: 43743
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: WINGERTER LABS, INC.
Region: 1
City: MIAMI State: FL
County:
License #: 0673-1
Agreement: Y
Docket:
NRC Notified By: STEVE FURNANCE
HQ OPS Officer: JOHN MacKINNON
Licensee: WINGERTER LABS, INC.
Region: 1
City: MIAMI State: FL
County:
License #: 0673-1
Agreement: Y
Docket:
NRC Notified By: STEVE FURNANCE
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/24/2007
Notification Time: 16:48 [ET]
Event Date: 10/24/2007
Event Time: 15:30 [EDT]
Last Update Date: 10/25/2007
Notification Time: 16:48 [ET]
Event Date: 10/24/2007
Event Time: 15:30 [EDT]
Last Update Date: 10/25/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JOHN CARUSO (R1)
LAWRENCE KOKAJKO (FSME)
ILTAB (EMAILED)
JOHN CARUSO (R1)
LAWRENCE KOKAJKO (FSME)
ILTAB (EMAILED)
FLORIDA AGREEMENT STATE REPORT - STOLEN/LOST TROXLER MOISTURE DENSITY GAUGE
"Licensee called 10/24/07 at 1640 hours and reported that a Troxler gauge is missing. It was last seen on 10/24/07. Troxler gauge was sitting on tailgate while operator was writing paperwork in vehicle cab. Operator drove off with gauge on tailgate. Wingerter employees searching area for gauge. It was reported missing to the North Miami PD. The Radioactive Materials Office is investigating. No further action will be taken by this office."
Incident Location: Intersection of Curtiss Drive and Pervis Avenue Opalocka, FL
Isotope(s) Cs-137; Be:Am-241 Activity(s): 8mCi; 40mCi
Material Form: Chemical Form; Physical Form: By-product; Special Form
Probable Disposition of Material: Material stolen and not recovered.
Emergency Groups at Scene: North Miami PD
Incident Number: FL07-163
* * * UPDATE PROVIDED BY STEVE FURNACE TO JASON KOZAL ON 10/25/07 AT 1308 * * *
The lost Troxler was recovered by the licensee at the intersection of NW 103rd St and NW 27th Ave Opalocka, FL. The device appears to have fallen off the vehicle tailgate at this location. The case was damaged but the source remained unharmed and locked in the shielded position. Surveys taken revealed no external contamination or indication of leakage. The device will be returned to the manufacturer for repair.
Notified R1DO (Caruso), ILTAB (Via E-mail) and NMSS EO (Morell).
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
"Licensee called 10/24/07 at 1640 hours and reported that a Troxler gauge is missing. It was last seen on 10/24/07. Troxler gauge was sitting on tailgate while operator was writing paperwork in vehicle cab. Operator drove off with gauge on tailgate. Wingerter employees searching area for gauge. It was reported missing to the North Miami PD. The Radioactive Materials Office is investigating. No further action will be taken by this office."
Incident Location: Intersection of Curtiss Drive and Pervis Avenue Opalocka, FL
Isotope(s) Cs-137; Be:Am-241 Activity(s): 8mCi; 40mCi
Material Form: Chemical Form; Physical Form: By-product; Special Form
Probable Disposition of Material: Material stolen and not recovered.
Emergency Groups at Scene: North Miami PD
Incident Number: FL07-163
* * * UPDATE PROVIDED BY STEVE FURNACE TO JASON KOZAL ON 10/25/07 AT 1308 * * *
The lost Troxler was recovered by the licensee at the intersection of NW 103rd St and NW 27th Ave Opalocka, FL. The device appears to have fallen off the vehicle tailgate at this location. The case was damaged but the source remained unharmed and locked in the shielded position. Surveys taken revealed no external contamination or indication of leakage. The device will be returned to the manufacturer for repair.
Notified R1DO (Caruso), ILTAB (Via E-mail) and NMSS EO (Morell).
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.