Power Reactor
Event Number: 43611
Facility: CALLAWAY
Region: 4     State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: STEVE KOCHERT
HQ OPS Officer: JEFF ROTTON
Notification Date: 08/31/2007
Notification Time: 11:05 [ET]
Event Date: 08/31/2007
Event Time: 07:03 [CDT]
Last Update Date: 08/31/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
REBECCA NEASE (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF EMERGENCY RESPONSE CAPABILITY - TSC SUPPORT CENTER (TSC) DUE TO PLANNED ELECTRICAL MAINTENANCE

"This report is being made pursuant to 10CFR50.72(b)(3)(xiii), 8-hour Non-Emergency Report due to the loss of emergency assessment capability. The normal AC power supply and backup diesel generator were taken out of service for planned load center cleaning maintenance activities and the Technical Support Center (TSC) was declared non functional at 0703 Central Daylight Time on 8/31/2007. The maintenance activities are expected to last approximately 16 hours. Affected Emergency Response Organization members have been, instructed to report to designated backup facilities, per procedure EIP-ZZ-00240, in the event of an emergency.

"Though this does not affect state or local response capabilities, the SEMA Senior Radiological Emergency Program Planner and local personnel have been notified of this planned maintenance outage as a courtesy.

"The licensee has notified the NRC Resident Inspector."

* * * UPDATE ON 08/31/07 AT 1730 EDT BY STEVE KOCHERT TO MACKINNON * * *

"The normal AC power supply and backup diesel generator were restored to service and the TSC was declared functional at 1627 CDT on 8/31/2007. Affected Emergency Response Organization members have been instructed to resume normal use of the TSC in the event of a emergency.

"The licensee has notified the NRC Resident Inspector."

R4DO (Troy Pruett) notified.


General Information or Other
Event Number: 43626
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: QSA GLOBAL, INC
Region: 1
City: BURLINGTON   State: MA
County:
License #: 12-8361
Agreement: Y
Docket: 09-7304
NRC Notified By: MIKE WHALEN
HQ OPS Officer: JASON KOZAL
Notification Date: 09/10/2007
Notification Time: 12:46 [ET]
Event Date: 08/31/2007
Event Time: 00:00 [EDT]
Last Update Date: 09/10/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JAMES TRAPP (R1)
MICHELE BURGESS (FSME)
ILTAB (email)
Event Text
AGREEMENT STATE REPORT - AM-241 SOURCES LOST DURING SHIPMENT

The State provided the following information via facsimile:

"Licensee received routine shipment of Am-241 button sources from supplier in China - Shenzhen CIC in Shenzhen, China on August 15, 2007. Shipment was sent via China Air from China to New York, and then transported by air to Boston. In Boston, it is then trucked via Ground Control and arrived at the licensees facility in Burlington, MA. The licensee estimates the package was sent from China sometime after July 25, 2007.

"The excepted package (UN2911) was damaged when it arrived at the licensees' facility. At this time the licensee confirmed there was no contamination nor high radiation levels from the package. This package is normally not opened as it is forwarded to a customer for use in smoke detectors. On August 31, 2007, before forwarding the package, the licensee opened the package to verify its contents. The licensee discovered that 2 vials from the package were missing.

"Each plastic vial contains 500 Am-241 button sources, each 0.8 microCi nominal activity, for a total of 0.4 milliCi total in each vial.

"The licensee immediately notified their transport broker and their agent in China."

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source