Event Notification Report for August 01, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/31/2007 - 08/01/2007

EVENT NUMBERS
43559435414354343554

General Information or Other
Event Number: 43559
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: THERMO NITON ANALYZERS LLC
Region: 1
City: BILLERICA   State: MA
County:
License #: 55-0328
Agreement: Y
Docket:
NRC Notified By: JOSH DAEHLER
HQ OPS Officer: BILL HUFFMAN
Notification Date: 08/10/2007
Notification Time: 12:12 [ET]
Event Date: 08/01/2007
Event Time: 00:00 [EDT]
Last Update Date: 08/10/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ROBERT SUMMERS (R1)
LINDA SMITH (R4)
RON ZELAC (FSME)
Event Text
AGREEMENT STATE REPORT - MASSACHUSETTS - RECEIPT OF LEAKING SOURCES

The State provided the following information via facsimile:
"Thermo NITON Analyzers LLC reported that it had received 10 (ten) sealed sources from Isotopes Products Laboratories (IPL) that were contaminated or leaking sources. Five (5) of the sealed sources exceeded leak test reporting limits of 0.005 microcuries (185 Bq) removable activity and five (5) sources were contaminated, but with less than 0.005 microcuries (185 Bq) removable activity.

"The ten (10) sealed sources were each identified as IPL Model XFB-3, each containing 40 millicuries of Cd-109. Each sealed source was individually wipe tested by Thermo NITON Analyzers LLC and each wipe test was analyzed by a licensed consultant.

"Thermo NITON Analyzers LLC shipped back the affected sealed sources to IPL via Federal Express Priority Overnight shipment on 8/1/07. Thermo NITON Analyzers LLC stated that IPL is in licensed possession of the sources in Burbank, CA where they are being evaluated by their quality group.

"The area where the source leak tests were acquired was surveyed thoroughly by Thermo NITON Analyzers LLC and no contamination was found.

"Thermo NITON Analyzers LLC reports that the following five (5) sources exceeded the reporting limit of 0.005 microcuries by the amount indicated.

1. Serial Number NR9014 was 1.02 times the state limit of 0.005 microcuries.
2. Serial Number NR9012 was 1.08 times the state limit of 0.005 microcuries.
3. Serial Number NR9019 was 1.00 times the state limit of 0.005 microcuries.
4. Serial Number NR9020 was 2.46 times the state limit of 0.005 microcuries.
5. Serial Number NR9011 was 2.88 times the state limit of 0.005 microcuries.

"Thermo NITON Analyzers LLC reports that the following five (5) sources were contaminated but did not exceed the reporting limit of 0.005 microcuries. The percent of the limit is reported below.

1. Serial Number NR9016 was 44% of the state limit of 0.005 microcuries.
2. Serial Number NR9013 was 18% of the state limit of 0.005 microcuries.
3. Serial Number NR9015 was 34% of the state limit of 0.005 microcuries.
4. Serial Number NR9018 was 42% of the state limit of 0.005 microcuries.
5. Serial Number NR9017 was 26% of the state limit of 0.005 microcuries".


Power Reactor
Event Number: 43541
Facility: HATCH
Region: 2     State: GA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: TONY SPRINGS
HQ OPS Officer: BILL HUFFMAN
Notification Date: 08/01/2007
Notification Time: 02:55 [ET]
Event Date: 08/01/2007
Event Time: 02:05 [EDT]
Last Update Date: 08/01/2007
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
JAMES MOORMAN (R2)
BRIAN McDERMOTT (IRD)
BILL TRAVERS (R2)
JIM DYER (NRR)
PATRICK HILAND (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 91 Power Operation
Event Text
UNUSUAL EVENT DECLARED DUE TO FIRE IN PROTECTED AREA GREATER THAN 10 MINUTES

"An Unusual Event was declared based on a fire lasting > 10 minutes within the Protected Area. Fire was on a Pole Mounted Transformer located on the 230 KV Supplemental Power System in the North East corner of the Protected Area. Helper Cooling Tower Fans were lost and sequenced back on. Unit 1 maintained 100% Rated Thermal Power. Unit 2 reduced power to 91.2% due to increasing Circulating Water Temperatures per procedure. Fire was extinguished at 0213 using dry chemical fire extinguishers."

Fire was initially spotted at 0152 EDT. It is believed that a snake may have caused the transformer to arc and that the arcing caused the wood transformer pole to catch on fire. Other than the brief loss of helper cooling to the circ water, there was no other impact on the facility. No offsite assistance from the fire department was called or needed. The licensee terminated the Unusual Event at 0250 EDT.

The licensee notified local and State Authorities and the NRC Resident Inspector.


Power Reactor
Event Number: 43543
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GARY GARDNER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 08/01/2007
Notification Time: 17:26 [ET]
Event Date: 08/01/2007
Event Time: 12:00 [EDT]
Last Update Date: 08/01/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JAMES MOORMAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
77 OUT OF 108 PROMPT NOTIFICATION SYSTEM SIRENS FAILED THEIR MONTHLY TEST


"On August 1, 2007, at 1200 Eastern Daylight time the prompt notification system (PNS) monthly test was performed and 77 of the 108 PNS sirens were not responsive to the test. This is considered to be a major loss of offsite response capability. Testing is being performed to ensure operability of the PNS sirens, trouble shooting has not identified the current problem with the system. 34 of the 77 sirens have been successfully tested and testing of the remaining sirens is being conducted."


State, Local and the NRC Resident Inspector have been notified of this by the licensee.


General Information or Other
Event Number: 43554
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: INTEGRITY INSPECTION SOLUTIONS
Region: 4
City: LAFAYETTE   State: LA
County:
License #: LA-11357-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JEFF ROTTON
Notification Date: 08/08/2007
Notification Time: 09:55 [ET]
Event Date: 08/01/2007
Event Time: 00:00 [CDT]
Last Update Date: 08/08/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
LINDA SMITH (R4)
RON ZELAC (FSME)
Event Text
RADIOGRAPHIC CAMERA SOURCE CONNECTOR ASSEMBLY MALFUNCTION

The following information was provided by the State via facsimile:

"On 8/1/07, one of Integrity Inspection Solutions crews was setting up for radiographic operations at a temporary job site. While connecting the crankout to the exposure device, the source connector assembly broke. Due to this happening before the first exposure on the job, there was no source disconnect. Another crankout was available and the job was completed. The crankout manufacturer could not be determined. The crankout will be sent to an authorized agent for repair. The crankout was used with a SPEC 150 camera."

LA Event Report ID No.: LA070023