Event Notification Report for July 04, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/03/2007 - 07/04/2007

EVENT NUMBERS
43473

Power Reactor
Event Number: 43473
Facility: GINNA
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: KEVIN McLAUGHLIN
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/04/2007
Notification Time: 02:42 [ET]
Event Date: 07/04/2007
Event Time: 02:14 [EDT]
Last Update Date: 07/04/2007
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
JOHN ROGGE (R1)
JOHN LUBINSKI (NRR)
JEFFREY CRUZ (IRD)
SAM COLLINS (RA)
JIM DYER (ET)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 98 Power Operation 98 Power Operation
Event Text
UNUSUAL EVENT DECLARED DUE TO A LOSS OF CONTROL ROOM ANNUNCIATORS

"Failure of main control board annunciator panels A, B, C, and D occurred at 0158 hours. At that time the control room had just commenced a load reduction to repair the turbine control valve #3. The load reduction was terminated at the time of the annunciator panel failure. Reactor power is 98.5%.

"Unusual Event EAL is 7.3.1

"RCS Pressure is 2235 psig
"RCS Temperature is 573 degrees"

The plant is currently stable and holding power. The Plant Process Computer remains operable monitoring at power parameters. The licensee has commenced an investigation to determine the cause of failure related to the power supply for the affected annunciator panels.

The licensee informed both State and local agencies and the NRC Resident Inspector.

* * * UPDATE PROVIDED BY SHIFT MANAGER (GARNISH) TO JEFF ROTTON AT 1553 ON 07/04/07 * * *

The licensee exited the Unusual Event at 1542 EDT on 07/04/07. All repairs have been completed, successful post maintenance test is complete, and all annunciator panels have been restored to operable condition. A blown fuse was discovered on the AA panel flasher card. The flasher cards for the AA panel and the A panel have been replaced. Two separate annunciator cards in the D panel have also been replaced.

The licensee informed both State and local agencies and the NRC Resident Inspector.

Notified R1DO (Rogge), NRREO (Lubinski), IRD (Cruz), R1 RA (Collins), NRR ET (Dyer), DHS (Frost), and FEMA (Dwight).