Event Number: 43371
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: CONAM INSPECTION AND ENGINEERING, INC.
Region: 4
City: PASADENA   State: TX
County:
License #: L05010
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/18/2007
Notification Time: 15:08 [ET]
Event Date: 05/17/2007
Event Time: 00:00 [CDT]
Last Update Date: 05/18/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
CYNTHIA FLANNERY (FSME)
Event Text
AGREEMENT STATE REPORT - SUSPECTED RADIATION BADGE OVEREXPOSURE

"The RSO called to notify the Agency that for the April '07 dosimeter report, a reading of 5,131 mrem was assigned to the dosimeter worn by a radiography trainee. This individual is no longer employed by the licensee.

"According to existing radiation reports, the trainee was not actively involved in performing industrial radiography for the said time period. He also claims to have stored his badge in a trailer for at least five days of the month opening a question to deliberate tampering. Radiography with Ir-192 was being performed in the general area but the trainee alleges that his participation was limited to a barricade watch. Other personnel with Conam support this recollection. [The Texas Department of Health Incident Investigation Program] will submit a completed report when the licensee and the Agency complete the investigation."

Event Report ID: 07-43371
Texas Incident No: I-8414


Power Reactor
Event Number: 43368
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BERNARD LITKETT
HQ OPS Officer: JASON KOZAL
Notification Date: 05/17/2007
Notification Time: 14:07 [ET]
Event Date: 05/17/2007
Event Time: 13:40 [EDT]
Last Update Date: 05/17/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
NEIL PERRY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO FAILED EMISSIONS TEST

"I am calling you to provide a notification of a potentially failed air emission test on an auxiliary boiler. There is absolutely no evidence to suggest that any emissions from our boilers caused any harm to human health, welfare, or the environment. The emissions are not continuing and there is no assistance required or requested. The statute requires I provide this notification to assert an affirmative defense or a rescission as appropriate. The New Jersey Department of Environmental Protection Hotline was called to report this, Case number 07-0517-134537, operator 27.

"During the start-up tuning and testing of our new auxiliary boilers, it appears that a malfunction of equipment during testing resulted in inconclusive test results for NOx loading for our #1 Boiler. For the testing runs, the measured volumetric stack flows were significantly higher than the stoichiometrically calculated stack flows based on fuel flow measurements.

"While we are still investigating this discrepancy, we preliminarily believe that it was the result of either equipment malfunction, performance of necessary equipment maintenance and equipment start-up and shutdown."

The licensee has notified the State (DEP) and will be notifying the NRC Resident Inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 43369
Facility: NINE MILE POINT
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: MATTHEW MINNICK
HQ OPS Officer: GERRY WAIG
Notification Date: 05/17/2007
Notification Time: 20:23 [ET]
Event Date: 05/17/2007
Event Time: 12:30 [EDT]
Last Update Date: 06/26/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
NEIL PERRY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
DEGRADED CONDITION - DEGRADATION OF PRINCIPAL SAFETY BARRIER

"Under 10CFR50.72 (b)(3)(ii)(A), the following event has been determined to be reportable. This section concerns the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded. This criteria was determined to apply to material problems that cause abnormal degradation of or stress upon a principal safety barrier (in this case, Reactor Coolant System).

"On 5/17/07, a Nine Mile Point Unit 1 shutdown was in progress for forced outage inspection and repairs of the Turbine Lube Oil system. Prior to the shutdown, a discrepancy was being experienced between Reactor level readings from channel 11 and 12 Reactor Level columns. A step change increase of 2 inches of Reactor level had occurred on May 6th, 2007 on Reactor Level column 12. This change was coincident with an increase of 18 [degrees] F of the reference leg and 2 [degrees] F decrease of the variable leg. The level difference was then 5 inches with a Technical Specification limit of 6 inches based on current Drywell temperature. The condition was documented in the Corrective Action Program, compensatory actions were taken, and an Integrated Response Team was formed to investigate and determine the cause. Calculations by engineering determined a leak of 4 drops per minute could explain the observed indications.

"During the initial drywell entry a visual examination was performed on the reference leg instrumentation line associated with Reactor Level Column 12. The piping was visually examined for any evidence of leakage. The exam was performed from the bottom of the condensing pot piping to the drywell shell penetration. The examination revealed a wet area at the bottom of a 1.0 inch 90 degree pipe elbow at an associated socket weld. The weld had one drop approximately 1.0 inch from the toe of the welds on the bottom of the pipe. The drop was wiped away with a leather gloved hand, which did show evidence of leakage. After waiting approx. 15 minutes, no additional leakage was observed. Reactor pressure had been lowered to approximately 400 psig at the time of the inspection due to the Reactor shutdown in progress. The piping, welds and Reactor level column above were closely examined and no other wetness or evidence of leakage was found. Also an exam was performed below pipe weld 012 (surrounding areas) and again no evidence of leakage could be found. No staining or other discoloration could be seen. The observations were documented in the Corrective Action Program."

The licensee also provided the following information:
Location of the Leak: 12 Yarway Reactor Level Reference Leg
Leak Rate: 1 drop per minute
T.S. Limits: 5 gallons per minute
Sudden or Long-term Development: Sudden
Leak Start Date: 5-06-2007
Time: 08:10 a.m. EDT
Coolant Activity: 2.02 E-3 microcuries/ml
Secondary: N/A
List of Safety Related Equipment Not Operational: None

The licensee has notified the NRC Resident Inspector.

* * * UPDATE AT 1705 EDT ON 06/26/07 FROM BRIAN FINCH TO J. ROTTON * * *

The licensee is retracting this report based on the following:

"Following plant shutdown the piping segment from the 12 Yarway Reactor Water Level Reference Leg initially believed to be leaking was removed from the station for examination and testing. The piping segment was subjected to a 1600 psig nitrogen pressure test for approximately one half hour with no indications of leakage. Additional nondestructive examinations were performed which also did not show evidence of through-wall indications. Based on the exploratory nondestructive examination and leak testing completed in the field and on the removed piping segment, it was determined that there was no actual leakage in the drywell associated with the 12 Yarway Reactor Water Level Reference Leg piping. Further leak testing identified a 5 to 6 drop-per-minute leak from the drain valves associated with the 12 Yarway Reactor Water Level Reference Leg. Based on engineering analysis, this amount of leakage through the drain valve assemblies accounted for the level instrumentation differences noted between channel 11 and 12 Reactor Water Level columns.

"Following maintenance and repair activities, in-situ leak checks were performed on the reference leg piping in the drywell and the associated instrument rooms outside the drywell during plant startup on 5/22/2007 at approximately 900 psi with no leakage identified.

"Due to the leakage being identified in the valve assemblies for the level instrumentation and not in the piping inside the drywell, this issue does not represent a reportable condition under 10CFR50.72 and therefore is being retracted."

The drain valve has been repaired. The licensee informed the NRC Resident Inspector. Notified R1DO(Powell).


General Information or Other
Event Number: 43377
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: LARGO MEDICAL CENTER
Region: 1
City: LARGO   State: FL
County:
License #: 1284-1
Agreement: Y
Docket:
NRC Notified By: STEVE FURNACE
HQ OPS Officer: JOHN KNOKE
Notification Date: 05/21/2007
Notification Time: 14:40 [ET]
Event Date: 05/17/2007
Event Time: 00:00 [EDT]
Last Update Date: 05/22/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
EUGENE COBEY (R1)
MICHELE BURGESS (FSME)
Event Text
AGREEMENT STATE REPORT - MEDICAL EVENT

"RSO contacted this office [Florida Bureau of Radiation Control] at 1335 hours 21-May-2007 to report a medical event. Patient has metastatic cancer and no thyroid. Doctor prescribed a whole body scan. Technologist gave patient a therapy dosage for the cancer, instead of the scan. Doctor and patient notified of misadministration. This incident referred to the radioactive materials office for investigation. No further action will be taken on this incident."

The therapy dosage administered was 26.8 mCuries of I-131 in liquid form.

Florida Incident number: FL07-081

* * * UPDATE BY E-MAIL AT 1547 EDT ON 5/22/2007 FROM C. FLANNERY TO JEFF ROTTON * * *

"This event has been reviewed and determined to be a reportable medical event."

A "Medical Event" may indicate potential problems in a medical facility's use of radioactive materials. It does not necessarily result in harm to the patient.


General Information or Other
Event Number: 43399
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: SEATTLE IRON AND METALS
Region: 4
City: SEATTLE   State: WA
County:
License #: WN-R1180
Agreement: Y
Docket:
NRC Notified By: ARDEN SCROGGS
HQ OPS Officer: JASON KOZAL
Notification Date: 06/01/2007
Notification Time: 13:25 [ET]
Event Date: 05/17/2007
Event Time: 00:00 [PDT]
Last Update Date: 06/01/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
GREG MORELL (FSME)
Event Text
AGREEMENT STATE REPORT - NITON DEVICE SHUTTER MALFUNCTION

"ABSTRACT: (where, when, how, why; cause, contributing factors, corrective actions, consequences, Dept. of Health (DOH) on-site investigation; media attention):

"The licensee's radiation contact individual notified Washington Department of Health (DOH) on 18 May 2007 that their Niton XLp 818 device's [used for metal composition identification] shutter mechanism malfunctioned. It contains a 30-millicurie americium-241 sealed source.

"On the morning of May 17, 2007 when the licensee attempted to start their analyzer, it failed to start properly. They called the manufacturer who was unable rectify the problem over the phone. They performed a shutter test using a Ludlum Model 19 survey meter; the reading was approximately 90 microR per hour which was greater than expected. As instructed by the manufacturer's service representative, the analyzer was packaged, properly labeled and shipped back to the manufacturer's location in Rhode Island via Federal Express. The manufacturer will repair the malfunction and perform shutter and device leak tests.

"DOH verified with the manufacturer's technical contact that the proper packaging included lead shielding adequate to completely shield the source and shutter, even if the shutter was stuck full open.

"No DOH on-site investigation. No known media attention.

"Notification Reporting Criteria:

"Per WAC 246-233-020 General License - Certain measuring, gauging or controlling devices.

"Isotope and Activity involved: one 30-millicurie americium-241 sealed source.

"Overexposures? Unknown but most likely not. The unit was functioning properly on 16 May 2007, but first thing in the morning on 17 May 2007 the unit would not start up properly. It was then the malfunction was discovered. No workers were exposed. The RCI (radiation contact individual) and one supervisor were the only people to handle this instrument after it had failed.

"Lost, Stolen or Damaged? (mfg., model, serial number): No loss or stolen. No obvious damage. It did not appear that it was dropped or anything happened to it between shut down on 16 May 2007 and start up on 17 May 2007.

"Leak test? Shutter tests have been performed and documented every six months. Most recent leak test was 13 December 2005 (no contamination, < 0.000002 microcuries)."

WA report number : WA-07-048