Skip to main content

Event Notification Report for May 11, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/10/2007 - 05/11/2007

EVENT NUMBERS
43359

Fuel Cycle Facility
Event Number: 43359
Facility: GLOBAL NUCLEAR FUEL - AMERICAS
Region: 2     State: NC
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: LEU CONVERSION (UF6 TO UO2)
LEU FABRICATION
LWR COMMERICAL FUEL
NRC Notified By: PHILLIP OLLIS
HQ OPS Officer: JEFF ROTTON
Notification Date: 05/12/2007
Notification Time: 12:07 [ET]
Event Date: 05/11/2007
Event Time: 16:00 [EDT]
Last Update Date: 05/12/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MIKE ERNSTES (R2)
SCOTT FLANDERS (FSME)
Event Text
BULLETIN 91-01 LOSS OF DOUBLE CONTINGENCY

"During the quarterly shutdown and clean-out of a rotary press used for pressing UO2-Gd203 powder in FMO, it was observed that approximately half of the schedule 80, one-inch diameter Chlorinated Poly Vinyl Chloride (CPVC) tubes placed in the lower shaft casing of the press did not extend the full length of the cavity as required by the nuclear safety analysis. These tubes are credited as a fixed neutron poison inside the casing and must extend the entire length of the cavity in order for the unit to be demonstrated safe geometry for [LEU] enriched UO2 under optimal moderation conditions. The independent control on mass remained intact, thus no unsafe condition existed. The as-found condition was analyzed and demonstrated to be safe.

"The unit was in a shutdown condition and contained no Uranium at the time of the discovery.

"While this did not result in an unsafe condition, this event is being reported pursuant to NRC Bulletin 91-01 within 24 hours of discovery.

"NUMBER AND TYPES OF CONTROLS NECESSARY UNDER NORMAL OPERATING CONDITIONS
The basis of criticality safety relies on geometry and mass as independent criticality safety controls.

"NUMBER AND TYPES OF CONTROLS WHICH FUNCTIONED PROPERLY UNDER UPSET CONDITIONS
Mass control remained intact, thus no unsafe condition existed.

"NUMBER AND TYPES OF CONTROLS NECESSARY TO RESTORE A SAFE SITUATION
Control on geometry demonstrated by current analysis. No uranium present at time of discovery.

"SAFETY SIGNIFICANCE OF EVENTS
Low Safety Significance - independent control on mass remained intact - additional failure modes required before a criticality accident could occur. The as-found condition was analyzed and demonstrated to be safe.

"SAFETY EQUIPMENT STATUS
Unit was shutdown for maintenance and will remain Shutdown until CPVC tube error corrected.

"STATUS OF CORRECTIVE ACTIONS
Unit will remain shutdown pending final investigation results and implementation of additional preventive actions."

The licensee will be notifying the North Carolina Radiation Protection Agency and the New Hanover County Emergency Management Agency.