Event Notification Report for April 23, 2007
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/22/2007 - 04/23/2007
Power Reactor
Event Number: 43313
Facility: VOGTLE
Region: 2 State: GA
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MARK SLIVKA
HQ OPS Officer: STEVE SANDIN
Region: 2 State: GA
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: MARK SLIVKA
HQ OPS Officer: STEVE SANDIN
Notification Date: 04/23/2007
Notification Time: 11:25 [ET]
Event Date: 04/23/2007
Event Time: 10:24 [EDT]
Last Update Date: 04/23/2007
Notification Time: 11:25 [ET]
Event Date: 04/23/2007
Event Time: 10:24 [EDT]
Last Update Date: 04/23/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOEL MUNDAY (R2)
JOEL MUNDAY (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 53 | Power Operation | 0 | Hot Standby |
AUTOMATIC REACTOR TRIP DUE TO GENERATOR GROUND RELAY ACTUATION
"Vogtle Unit 2 tripped from 53% power due to a turbine trip /P9 reactor trip RPS actuation during power ascension following completion of refueling outage 2R12. Initial investigation indicates that a generator neutral ground relay actuated causing an automatic main generator turbine trip. No visual damage is apparent on any plant equipment.
"All systems responded as expected. Both motor driven auxiliary feedwater pumps and the turbine driven started on lo-lo steam generator level and AMSAC.
"The NRC Resident Inspector was notified."
All control rods fully inserted upon RPS actuation, the atmospheric relief valves lifted momentarily and reseated as expected, and no safety valves lifted. After the trip, steam generator level was being maintained with auxiliary feed pumps and steam was being dumped to the condenser. The plant was placed in the normal shutdown electrical lineup.
"Vogtle Unit 2 tripped from 53% power due to a turbine trip /P9 reactor trip RPS actuation during power ascension following completion of refueling outage 2R12. Initial investigation indicates that a generator neutral ground relay actuated causing an automatic main generator turbine trip. No visual damage is apparent on any plant equipment.
"All systems responded as expected. Both motor driven auxiliary feedwater pumps and the turbine driven started on lo-lo steam generator level and AMSAC.
"The NRC Resident Inspector was notified."
All control rods fully inserted upon RPS actuation, the atmospheric relief valves lifted momentarily and reseated as expected, and no safety valves lifted. After the trip, steam generator level was being maintained with auxiliary feed pumps and steam was being dumped to the condenser. The plant was placed in the normal shutdown electrical lineup.
General Information or Other
Event Number: 43314
Rep Org: NE DIV OF RADIOACTIVE MATERIALS
Licensee: WESTFIELD AT GATEWAY MALL
Region: 4
City: LINCOLN State: NE
County:
License #: GL0457
Agreement: Y
Docket:
NRC Notified By: TRUDY HILL
HQ OPS Officer: JOHN MacKINNON
Licensee: WESTFIELD AT GATEWAY MALL
Region: 4
City: LINCOLN State: NE
County:
License #: GL0457
Agreement: Y
Docket:
NRC Notified By: TRUDY HILL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 04/23/2007
Notification Time: 16:24 [ET]
Event Date: 04/23/2007
Event Time: 15:00 [CDT]
Last Update Date: 04/23/2007
Notification Time: 16:24 [ET]
Event Date: 04/23/2007
Event Time: 15:00 [CDT]
Last Update Date: 04/23/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
LINDA SMITH (R4)
GREG MORELL (FSME)
ILTAB (e-mailed)
LINDA SMITH (R4)
GREG MORELL (FSME)
ILTAB (e-mailed)
NEBRASKA AGREEMENT STATE REPORT - THREE MISSING SELF LUMINOUS SIGNS CONTAINING TRITIUM
The licensee provided the following information via e-mail
"The licensee received six model 880-12-6-20 self-luminous signs from Safety Light Corporation in May of 1994. The report from Safety Light did not list serial numbers. The licensee's facility was remodeled in 2005. They have done a number of searches for the missing signs and have not been able to locate them. The licensee does not know where they are. They assume that the signs were misplaced during the remodel. This Department does not have the model numbers as they were not a part of the report from Safety Light in 1994. The licensee previously had not done a complete inventory to record the serial numbers."
Event Cause: Inattention to Detail
Corrective Action: No Corrective Action Taken
Each of the three missing Safety Light Corporation signs initially contained 11.5 cuires/425.5 GBq of Tritium
Event Date: 07/01/2005
Reporting Requirement: 20.2201(a)(1)(i) - Report of theft or loss of licensed material > 1000 x App C value
Reference Number: 04-20-07
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source
The licensee provided the following information via e-mail
"The licensee received six model 880-12-6-20 self-luminous signs from Safety Light Corporation in May of 1994. The report from Safety Light did not list serial numbers. The licensee's facility was remodeled in 2005. They have done a number of searches for the missing signs and have not been able to locate them. The licensee does not know where they are. They assume that the signs were misplaced during the remodel. This Department does not have the model numbers as they were not a part of the report from Safety Light in 1994. The licensee previously had not done a complete inventory to record the serial numbers."
Event Cause: Inattention to Detail
Corrective Action: No Corrective Action Taken
Each of the three missing Safety Light Corporation signs initially contained 11.5 cuires/425.5 GBq of Tritium
Event Date: 07/01/2005
Reporting Requirement: 20.2201(a)(1)(i) - Report of theft or loss of licensed material > 1000 x App C value
Reference Number: 04-20-07
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source