Event Notification Report for April 22, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/21/2007 - 04/22/2007

EVENT NUMBERS
43312

Fuel Cycle Facility
Event Number: 43312
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 2     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: WF CAGE
HQ OPS Officer: JASON KOZAL
Notification Date: 04/22/2007
Notification Time: 13:53 [ET]
Event Date: 04/22/2007
Event Time: 03:20 [CDT]
Last Update Date: 04/22/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
JOEL MUNDAY (R2)
KEITH McCONNELL (FSME)
Event Text
UF6 RELEASE DETECTION SYSTEM INOPERABLE

"At 0320 CDST, on 4-22-07 the Plant Shift Superintendent (PSS) was notified that the control power for C-337A #1 Autoclave had been lost due to a blown control power fuse. Investigation of a problem with the Autoclave 1 West CV-510 valve close indicating light not functioning properly was in progress at the time the fuse blew. Maintenance personnel were performing non-intrusive checks of the valve's limit switch and had activated the limit switch operating plunger when the fuse blew. No maintenance work package was used for these checks. The power supply for the local autoclave area audible and visible alarms for the UF6 Release Detection System are fed from the #1 Autoclave control power. Due to this loss of control power, the UF6 Release Detection System was rendered inoperable. At the time of the incident, the C-337A facility was operating in an operational mode in which the UF6 Release Detection System was required to be operable, TSR 2.2.4.1 Mode 5. The C-337A Operations Monitoring Room where UF6 Release Detection System alarms would have been received was unoccupied at the time of the fuse failure due to C-337A personnel in the autoclave area assisting with the CV-510 light investigation. The system was declared inoperable and Limiting Conditions of Operation (LCO) required action, TSR 2.2.4.1 A.1, was put in place until power could be restored. Subsequent troubleshooting revealed the CV-510 limit switch was broken and has shorted the control circuit to ground when activated causing the fuse to blow. Power was restored and the UF6 Release Detection System was declared operable at 0539 on 4-22-07 following repairs and PMT.

"The event is reportable as a 24 hour event as required by 10 CFR 76.120(c)(2)(i); An event in which equipment is disabled or fails to function as designed when the equipment is required by TSR to be available and operable and no redundant equipment was available to perform the required safety function.

"The NRC Senior Resident Inspector has been notified of this event."