Fuel Cycle Facility
Event Number: 43255
Facility: BWX TECHNOLOGIES, INC.
Region: 2     State: VA
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
NRC Notified By: LEAH MORRELL
HQ OPS Officer: JOHN KNOKE
Notification Date: 03/23/2007
Notification Time: 08:22 [ET]
Event Date: 03/22/2007
Event Time: 08:30 [EDT]
Last Update Date: 05/11/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
PART 70 APP A (b)(1) - UNANALYZED CONDITION
Person (Organization):
MARK LESSER (R2)
GREG MORELL (FSME)
FUEL OUO EMAIL
Event Text
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
THIS IS NOT A NEW REPORT.

This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

POSSIBLE UNANALYZED CONDITION OF MASS-MODERATOR CONTROLLED GLOVEBOX

"At approximately 8:30 am on March 22, 2007, NCS [Nuclear Criticality Safety] was questioned by an NRC inspector regarding control methods for the RTRT [Research Test Reactor & Targets], HEU [High Enriched Uranium] and LEU [Low Enriched Uranium] compact press glovebox lines regarding hydraulic fluid entry into the glovebox. The glove box is a mass-moderator controlled box. Mass and moderator upset conditions were considered during the ISA [Integrated Safety Analysis] and are documented in the SAR. However, no moderator upset condition (reflecting hydraulic leak into the press box) is documented in the SAR. Moderator upset (reflecting hydraulic leak into the box) is considered in the NCS analysis supporting the SAR analysis and operation. Moderator upset was specifically evaluated, and results documented in the NCS analysis. The evaluation demonstrated the glovebox remained subcritical and below license limits even if fully flooded with hydraulic fluid.

"At the time of discovery, the glovebox line was not in operation and there was no evidence of a hydraulic leak. Soon after notification, RTRT Operations removed the glove boxes from service and the press glovebox operations were subsequently locked out from use.

"At this time BWXT believes this may be an unanalyzed condition in the ISA and is therefore reporting this event under 10 CFR 70, Appendix A (b)(1). BWXT continues to research the ISA documentation to determine the extent of the evaluation during the ISA. If more information is found BWXT may withdraw this notification.

"BWXT has notified the NRC Resident Inspector."

* * * UPDATE 05/11/08 BY P. SNYDER * * *

THIS IS NOT A NEW REPORT.

This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.