Power Reactor
Event Number: 43224
Facility: HATCH
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: FRANK GORLEY
HQ OPS Officer: JEFF ROTTON
Notification Date: 03/09/2007
Notification Time: 06:23 [ET]
Event Date: 03/09/2007
Event Time: 00:30 [EST]
Last Update Date: 03/09/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
GEORGE HOPPER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
MAIN STEAM LINE FLOW INSTRUMENT LINE PRESSURE BOUNDARY LEAKAGE

"With Unit 2 in Mode 4 for a planned refueling outage, a one-inch socket weld elbow on an instrument line off the 'D' main steam line was identified as leaking water. Leakage was quantified as less than 20 drops per minute (with the main steam lines full of water).

"This elbow is on a steam line flow instrument (just below its condensing chamber) and is located in the Unit 2 drywell (primary containment).

"This item constitutes a primary coolant boundary leak discovered while shutdown."

A pressure test is planned to be performed after the repair of the instrument line elbow is completed.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 43225
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GRANT FERNSLER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/09/2007
Notification Time: 14:32 [ET]
Event Date: 03/09/2007
Event Time: 13:45 [EST]
Last Update Date: 03/09/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(ii)(A) - DEGRADED CONDITION
Person (Organization):
NEIL PERRY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
SECONDARY CONTAINMENT BYPASS LEAKAGE RATE EXCEEDED

"Appendix J Local Leak Rate Testing has determined that Tech Spec Acceptance Criteria for Secondary Containment Bypass Leakage has been exceeded. During the performance of SE-259-044 the combined SCBL limit of 9scfh was exceeded. Test results were within Administrative and Acceptance Criteria for the 10CFR50 Appendix J limits of 0.6La. The leakage limit is 9scfh. The identified degraded condition is reportable as a condition of the nuclear power plant, including its principle safety barriers being seriously degraded per 10CFR50.72(b)(3)(ii)."

The NRC Resident Inspector was notified of this event by the licensee.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 43226
Facility: VOGTLE
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: TIMOTHY THOMPSON
HQ OPS Officer: PETE SNYDER
Notification Date: 03/09/2007
Notification Time: 14:48 [ET]
Event Date: 03/09/2007
Event Time: 14:23 [EST]
Last Update Date: 05/12/2007
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED
Person (Organization):
GEORGE HOPPER (R2)
MARY JANE ROSS-LEE (NRR)
LOREN PLISCO (R2)
JIM DYER (NRR)
DUNKER (FEMA)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
UNUSUAL EVENT DECLARED DUE TO RCS LEAKAGE GREATER THAN TECH SPEC LIMIT

"A Notification of Unusual Event has occurred on Unit 2 due to Reactor Coolant System (RCS) unidentified leakage greater than 10 gallons per minute."

The licensee notified NRC Resident Inspector. Notified USDA (Brzostels).

* * * UPDATE AT 1754 ON 3/9/06 FROM T. PETRAK TO P. SNYDER * * *

"No actual RCS leakage occurred and the RCS always remained intact. The additional water injection occurred and the RCS always remained intact. The additional water injection into the Reactor Coolant System was required to makeup for gases that came out of solution and accumulated in the reactor vessel head and were being vented from the RCS during a planned drain down."

The licensee terminated the Unusual Event at 1751 on 3/9/07. The licensee notified the NRC Resident Inspector, state, and local government agencies. The licensee will remain in Mode 5 for their planned outage.

Notified R2DO (G. Hopper), NRR EO (M. Case), IRD (T. Blount), NRR (J. Dyer), DHS (McKentry), FEMA (Biscoe), DOE (Wyatt), EPA (Burgess), HHS (Dalviel), USDA (Giles).

* * * UPDATE AT 1531 EDT ON 5/11/07 FROM ROBERT DORMAN TO GERRY WAIG * * *

This report is retracted based on the following:

"On 3/9/07, an NOUE was declared while Unit 2 was in Mode 5, draining the RCS to support Rx Vessel disassembly, due to what was then diagnosed as an RCS Unidentified Leak greater than 10 gpm. Subsequent review of the event revealed that no leak existed and the mismatch between charging and letdown, which was the basis of the leak determination, was caused by a nitrogen bubble being vented from the Rx Vessel Head and the additional charging volume was displacing the nitrogen volume as it was being vented. As a result, Vogtle Unit 2 is retracting the NOUE classification that was made on 3/9/07."

The licensee informed the NRC Resident Inspector. Notified R2DO (Ernstes).


Power Reactor
Event Number: 43227
Facility: CALLAWAY
Region: 4     State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DAVID G. LANTZ
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/09/2007
Notification Time: 15:02 [ET]
Event Date: 03/09/2007
Event Time: 10:43 [CST]
Last Update Date: 03/12/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(2)(xi) - OFFSITE NOTIFICATION 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
VINCENT GADDY (R4)
JIM DYER (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP AT REDUCED POWER DUE TO INADEQUATE FEEDWATER CONTROL

"At approximately 0803 Central Standard Time (CST) on 3/9/2007, Callaway Plant received indications of a condenser tube leak. At approximately 0826 CST, a power reduction from 100 percent to less than 5 percent was initiated in accordance with the Secondary Water Chemistry Program. At 1043 CST, with the reactor at approximately 30 percent power, a manual reactor trip was initiated due to inadequate feedwater control to the C steam generator. There was indication of feedwater flow to and increasing level in the C steam generator with both the main feedwater reg valve and its bypass valve closed. Cause of the inadequate feedwater control is under investigation.

"All safety systems functioned as designed with the exception of the digital rod position indication for control rod K10 which failed during the trip due to an existing problem. Control rod K10 is believed to be fully inserted, but is being treated as indeterminate at this time. Main feedwater isolation and motor-driven auxiliary feedwater actuations occurred as expected. Both trains of the emergency diesel generators and the offsite power supplies are available.

" Callaway plant is currently stable in Mode 3 at normal reactor coolant system parameters.

"This notification is being made in accordance with 10CFR50.72(b)(2)(iv)(B) for manual reactor trip (RPS actuation), 10CFR50.72(b)(2)(xi) for offsite notification and 10CFR50.72(b)(3)(iv)(A) Specified System Actuation.

"The licensee informed the resident inspector of the event and will be making State notifications. A press release is expected."


* * * UPDATE ON 03/12/07 AT 2116 EDT FROM S. GANZ TO MACKINNON * * *


"Repairs were made to the Digital Rod Position Indication (DRPI) for control rod K10. The cause was determined to be a bent pin on a cable connector. When DRPI was restored, control rod K10 was verified to be fully inserted. Post maintenance testing was completed satisfactorily.

"The cause of the inadequate feedwater control for the C steam generator was a failure of the positioner for the C main feedwater reg valve. The positioner was replaced and tested satisfactory.

"The plant is currently in Mode 2 (Startup)

"The resident inspector was informed of the update."

R4DO (Mike Shannon) notified.