Event Notification Report for March 08, 2007
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/07/2007 - 03/08/2007
EVENT NUMBERS
43223
Power Reactor
Event Number: 43223
Facility: NINE MILE POINT
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: ROY GREEN
HQ OPS Officer: JOHN MacKINNON
Region: 1 State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: ROY GREEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/08/2007
Notification Time: 16:15 [ET]
Event Date: 03/08/2007
Event Time: 14:50 [EST]
Last Update Date: 03/09/2007
Notification Time: 16:15 [ET]
Event Date: 03/08/2007
Event Time: 14:50 [EST]
Last Update Date: 03/09/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
JOHN CARUSO (R1)
JOHN CARUSO (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 50 | Power Operation |
TECHNICAL SPECIFICATION SHUTDOWN DUE TO A DEGRADED SEAL IN THE "A" REACTOR RECIRCULATION PUMP
"Reactor Recirculation Pump 'A' removed from service due to a degraded seal. TS 3.4.1 entered to meet requirement for single loop operation at 1050. When the pump was secured, the 3D monicore system failed preventing verification of thermal limits. TS 3.4.1 action D entered at 1450 required to be in mode 3 (Hot Shutdown) within 12 hours."
The NRC Resident Inspector was notified of this event by the licensee.
Reactor Recirculation Pump 'A' seal is degraded, no increase in leakage. Licensee is in contact with General Electric in trying to restore the 3D monicore system. All Emergency Core Cooling Systems and the Emergency Diesel Generators (all 3 divisions) are fully operable if needed and the electrical grid is stable. Nine Mile Point Unit 1 is in coastdown for a scheduled refueling outage. Nine Mile Point Unit 2 should be in Mode 3 (Hot Shutdown) by 0100 hours on 03/09/07.
* * * UPDATE AT 1241 EST ON 03/09/07 FROM CHRIS SKINNER TO MACKINNON * * *
"On March 8, 2007 at 1709, surveillance for thermal limit verification was completed satisfactorily and TS 3.4.1 was exited. The reactor was no longer required to be shutdown per Technical Specifications; however, the plant shutdown continued for performance of maintenance activities."
R1DO (Neil Perry) notified.
The NRC Resident Inspector was notified of this update by the licensee.
"Reactor Recirculation Pump 'A' removed from service due to a degraded seal. TS 3.4.1 entered to meet requirement for single loop operation at 1050. When the pump was secured, the 3D monicore system failed preventing verification of thermal limits. TS 3.4.1 action D entered at 1450 required to be in mode 3 (Hot Shutdown) within 12 hours."
The NRC Resident Inspector was notified of this event by the licensee.
Reactor Recirculation Pump 'A' seal is degraded, no increase in leakage. Licensee is in contact with General Electric in trying to restore the 3D monicore system. All Emergency Core Cooling Systems and the Emergency Diesel Generators (all 3 divisions) are fully operable if needed and the electrical grid is stable. Nine Mile Point Unit 1 is in coastdown for a scheduled refueling outage. Nine Mile Point Unit 2 should be in Mode 3 (Hot Shutdown) by 0100 hours on 03/09/07.
* * * UPDATE AT 1241 EST ON 03/09/07 FROM CHRIS SKINNER TO MACKINNON * * *
"On March 8, 2007 at 1709, surveillance for thermal limit verification was completed satisfactorily and TS 3.4.1 was exited. The reactor was no longer required to be shutdown per Technical Specifications; however, the plant shutdown continued for performance of maintenance activities."
R1DO (Neil Perry) notified.
The NRC Resident Inspector was notified of this update by the licensee.