Skip to main content

Event Notification Report for February 28, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/27/2007 - 02/28/2007

EVENT NUMBERS
432024319843199

Power Reactor
Event Number: 43202
Facility: ZION
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ARTHUR ADAMS
HQ OPS Officer: JOHN KNOKE
Notification Date: 02/28/2007
Notification Time: 14:16 [ET]
Event Date: 02/28/2007
Event Time: 13:05 [CST]
Last Update Date: 02/28/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
ROGER LANKSBURY (R3)
GREG MORELL (FSME)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Decommissioned 0 Decommissioned
2 N N 0 Decommissioned 0 Decommissioned
Event Text
EXTREMELY SMALL AMOUNT OF SNM UNACCOUNTED FOR


"This is a non-emergency event notification in accordance with 10 CFR 20.2201(a)(1)(ii) to report an accountability discrepancy of licensed material.

"In the process of reviewing records, it was identified that all disposition records for reactor incore detectors could not be found. The reactor incore detectors contain very small quantities of U-235 and were used to monitor reactor power at Zion Station from 1972 to 1988.

"The unaccounted for material was classified as missing on February 28, 2007 due to lack of records documenting the current location of the detectors; however, based on available records and discussions with former Zion Nuclear Material Custodians, it is believed that these detectors were shipped as radioactive waste to the Barnwell Low-Level Radioactive Waste Disposal Facility located in South Carolina. A search of storage locations at Zion was performed, but the detectors have not been located.

"Historical records indicate that it was common practice for Zion Station to dispose of detectors in this manner. There is no evidence of theft or diversion of these detectors. The incomplete records involve 43 incore detectors received onsite prior to 1988. The detectors contain an extremely small amount of Special Nuclear Material and pose no significant safety concern. Depending on design, each incore detector contained between 0.0025 grams to 0.0004 grams of Uranium 235 resulting in an aggregate quantity of approximately 0.102 grams of Uranium 235. The activity of this quantity is approximately 0.22 microcuries. This quantity is greater than the reportability threshold of 10 times the quantity specified in Appendix C to 10 CFR 20 which is 0.01 microcuries.

"A subsequent written report will be made in accordance with 10 CFR 20.2201(b)."

The licensee will notify the NRC Resident Inspector and the State.


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


Power Reactor
Event Number: 43198
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: DAVE BOWMAN
HQ OPS Officer: STEVE SANDIN
Notification Date: 02/28/2007
Notification Time: 05:53 [ET]
Event Date: 02/28/2007
Event Time: 01:20 [CST]
Last Update Date: 02/28/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
ROGER LANKSBURY (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 30 Power Operation 0 Hot Shutdown
Event Text
UNIT 2 REACTOR MANUALLY SCRAMMED DUE TO DECREASING CONDENSER VACUUM

"At 0120 hours on February 28, 2007 the Unit 2 Reactor was manually scrammed due to decreasing condenser vacuum. All control rods fully inserted during the scram. Reactor water level decreased to approximately -10", which resulted in automatic Group II and III isolations as expected. All systems responded properly to the event. Unit 2 remains in Mode 3, maintaining reactor pressure, with reactor water level in the normal level band. The cause of this event is still under investigation.

"Unit 1 was unaffected by the event and remains at 97% power.

"This report is being made in accordance with 10CFR50.72 (b)(2)(iv)(B) and 10CFR50.72 (b)(3)(iv)(A)."

The Main Condenser remains in service removing decay heat via the bypass valves. All ECCS equipment is available, if needed.

The licensee will inform the State and has informed the NRC Resident Inspector.


Power Reactor
Event Number: 43199
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: DAN LYON
HQ OPS Officer: PETE SNYDER
Notification Date: 02/28/2007
Notification Time: 10:01 [ET]
Event Date: 02/28/2007
Event Time: 06:35 [EST]
Last Update Date: 02/28/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
JOHN ROGGE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP FOLLOWING MALFUNCTION OF PRESSURE TRANSMITTER

"At approximately 0633 AM on February 28, 2007, control room operators manually initiated a reactor trip after observing decreasing steam generator levels as a result of low feed water flow. Control room alarms indicated low main feed water pump suction pressure which was subsequently, attributed to a malfunction of the main feed water pump low suction pressure cutback pressure transmitter (PT-408B) on the common main feed pump water supply header. The malfunction of the main feed pump water low suction cutback pressure transmitter resulted in a cutback of both main feed water pumps reducing main feed water flow to the steam generators and causing decreasing steam generator levels.

"All control rods fully inserted and all safety systems responded as expected. The auxiliary feedwater system actuated as expected from low steam generator levels which occurs as a result of a full power reactor trip. The emergency diesel generators (EDGs) did not start as offsite power remained available. The plant was stabilized in hot shutdown with the [Auxiliary Feedwater System] providing decay heat removal via the main condenser. The main feed water pumps are shutoff and secured.

"The event is under investigation and a post trip review is being conducted. A courtesy call to stakeholders will be made."

All EDGs remain available in standby. No steam generator Power Operated Relief Valves or Main Steam Safety Valves lifted.

The licensee notified state and will notify local authorities. The licensee plans to issue a press release. The licensee notified the NRC Resident Inspector.