Skip to main content

Event Notification Report for February 26, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/25/2007 - 02/26/2007

EVENT NUMBERS
43194431874318843309

Power Reactor
Event Number: 43194
Facility: NINE MILE POINT
Region: 1     State: NY
Unit: [] [2] []
RX Type: [1] GE-2,[2] GE-5
NRC Notified By: DAVE WILSON
HQ OPS Officer: JEFF ROTTON
Notification Date: 02/27/2007
Notification Time: 19:29 [ET]
Event Date: 02/26/2007
Event Time: 15:14 [EST]
Last Update Date: 02/27/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN ROGGE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
VOLUNTARY NOTIFICATION REGARDING RADIOACTIVE WASTE SHIPPING CASK CONFIGURATION

"This voluntary notification is being made to inform the NRC of a condition that may be of interest to the public.

"Upon arrival at the Barnwell South Carolina waste disposal facility, a shipping cask containing irradiated hardware that was shipped from Nine Mile Point Nuclear Station (NMPNS) [Unit 2] was observed to have a number of bolts that were not fully torqued [Six of 12 bolts were not fully torqued]. The subject bolts secure the cask base plate to the cask body. There was no radiological safety concern associated with the bolting condition as survey results confirmed that no radioactivity leaked from the cask. This issue has been entered into the NMPNS corrective action program and an investigation is underway to determine the cause of the as-received bolting condition."



The licenses notified the NRC Resident Inspector and New York Public Service Commission.


Power Reactor
Event Number: 43187
Facility: VOGTLE
Region: 2     State: GA
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: ROBERT DORMAN
HQ OPS Officer: PETE SNYDER
Notification Date: 02/26/2007
Notification Time: 09:41 [ET]
Event Date: 02/26/2007
Event Time: 04:00 [EST]
Last Update Date: 02/27/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
EUGENE GUTHRIE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 98 Power Operation 98 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
TECHNICAL SUPPORT CENTER CHILLER MALFUNCTION

"During the performance of rounds by a System Operator it was noticed that area temperatures in the TSC seemed higher than normal. The Control Room was notified and after investigating found that the TSC chiller was not running. An attempt was made to reset the freeze protection relay per the annunciator response procedure. The chiller would not start. Maintenance has been notified to investigate and repair the chiller. The importance of returning the chiller to service in a timely manner has been communicated to maintenance personnel and they will they will restore the chiller to operational status as soon as practical."

The licensee notified the NRC Resident Inspector.

* * * UPDATE PROVIDED BY THOMAS PETRAK TO JEFF ROTTON AT 1524 EST ON 02/27/07 * * *

One of two TSC Chiller compressors had failed. The failed compressor has been disabled and the chiller package returned to service on 2/26/2007 @ 13:24. The capacity of one compressor is sufficient to handle the design heat load. Ventilation, filtration and pressurization of the TSC HVAC were not affected by the failed compressor. A replacement compressor and fan are expected on-site by 3/1/2007 and repairs should be complete by 3/2/2007.

The licensee will notify the NRC Resident Inspector. Notified R2DO (Seymour)


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
General Information or Other
Event Number: 43188
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: SOUTHWEST RESEARCH INSTITUTE
Region: 4
City: SAN ANTONIO   State: TX
County:
License #: L00775
Agreement: Y
Docket:
NRC Notified By: ART TUCKER
HQ OPS Officer: JOHN KNOKE
Notification Date: 02/26/2007
Notification Time: 15:31 [ET]
Event Date: 02/26/2007
Event Time: 00:00 [CST]
Last Update Date: 04/02/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
SANDRA WASTLER (NMSS)
DALE POWERS (EMAIL) (R4)
Event Text
AGREEMENT STATE REPORT

"On 2/26/07 at about 13:30 the licensee notified the Agency that they had received 8 sources from White Sands Missile Base containing cobalt sixty (Co-60) sources. Four were estimated to have activities of 3,000 curies and four had estimated activities of 1,000 curies. Southwest opened one of the containers used to ship the sources to leak test the source. Upon opening the container, it appeared that the source was no longer contained in a source capsule. The leak test results indicated 5 million DPM. The container was resealed and no other containers were opened."

Containers were opened with automation equipment, therefore no exposure to personnel occurred.

TX Report TX-07-43188


* * * UDPATE ON 02/27/07 AT 0950 EST FROM ARTHUR TUCKER VIA E-MAIL TO MACKINNON * * *

"On 2/26/07 at about 11:00 the licensee notified the Agency that they had received eight (8) cobalt sixty sources from White Sands Missile Range. Each of the eight sources was contained in a separate container. Four sources had estimated activities of 3,000 curies and four had estimated activities of 1,000 curies. The outside of each container was surveyed after receipt and contamination levels were found to be below their limits. SWR opened one of the containers used to ship the sources to leak test the source. The source was a Neutron Products Inc. model no. NPU-25-13000 capsule serial # T-96-5. The container was opened in SWR hot cell using manipulator arms. Upon opening the source container, it appeared that the source capsule had been breached. The leak test results indicated 5 E6 dpm of contamination. The container was sealed and no other sources were opened. The sources were removed from the hot cell. The hot cell was surveyed and found to be contaminated. The hot cell was decontaminated and returned to service.

R4DO (Dale Powers) & NMSS EO (Greg Morell) notified.

* * * UPDATE PROVIDED BY ART TUCKER (STATE OF TEXAS) TO JEFF ROTTON AT 1652 EDT ON 04/02/07 * * *

"The State of Texas, Department of State Health Services, Radiation Control Program, is retracting event number TX-07-43188 [NRC EN #43188]. The eight sources sent to Southwest Research of San Antonio, Texas, were included in a group of sources identified at White Sands Missile Range in 1996 by the Nuclear Regulatory Commission (NRC) as failing during use. NMED item Number 960300, [and] NRC EN# 30353 documents this as well as an Executive Summary Report done by the United States Army. These sources were removed from service, and the source carrier and source itself were redesigned to operate as required. The State was not aware that the NRC had already addressed the source failures prior to sending our Event Notification [#43188] to the NRC."

R4DO (Chuck Cain) & FSME EO (Larry Camper) notified.


Other Nuclear Material
Event Number: 43309
Rep Org: SMITH MEDICAL ASD INC
Licensee:
Region: 3
City: GARY   State: IN
County:
License #:
Agreement: N
Docket:
NRC Notified By: THOM OLTMAN
HQ OPS Officer: GERRY WAIG
Notification Date: 04/18/2007
Notification Time: 15:18 [ET]
Event Date: 02/26/2007
Event Time: 00:00 [EDT]
Last Update Date: 04/18/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
THOMAS KOZAK (R3)
KEITH McCONNELL (FSME)
Event Text
LOST OR STOLEN STATIC ELIMINATOR Po - 210 SOURCE

On February 26, 2007 a 5 millicurie Polonium 210 source static eliminator button was identified as lost or stolen from a silicone extruder frame. The device was last used on February 23, 2007. The lost button was 1 of 3 buttons on the extruder. The device model number is P2042, serial number A2FD631. The static eliminator is leased from Amstat Industries, 3012 North Lake Terrace, Glenview, IL 60026. A department-wide search and an interview with all employees was conducted without success. It is believed that the button may have been swept up during floor cleaning and ultimately disposed of in a land fill. The search for the missing button will continue and corrective actions have been put in place to prevent reoccurrence.

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.