Skip to main content

Event Notification Report for January 01, 2007

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/31/2006 - 01/01/2007

EVENT NUMBERS
4306955073

General Information or Other
Event Number: 43069
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: HDR CONSTRUCTION CORP
Region: 1
City: TAMPA   State: FL
County: POLK
License #: 2763-1
Agreement: Y
Docket:
NRC Notified By: STEVE FURNACE
HQ OPS Officer: BILL HUFFMAN
Notification Date: 01/02/2007
Notification Time: 10:37 [ET]
Event Date: 01/01/2007
Event Time: 20:30 [EST]
Last Update Date: 01/10/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAYMOND LORSON (R1)
JOE GIITTER (NMSS)
ILTAB VIA E-MAIL
Event Text
AGREEMENT STATE REPORT - FLORIDA - STOLEN MOISTURE DENSITY GAUGE.

A truck belonging to the licensee flipped over on a highway in Polk County, FL on January 1, 2007, at approximately 8 or 9 pm. The truck was carrying a Humboldt Model 5001EZ moisture density gauge (nominal 50 millicuries Am-241/Be and 10 millicuries Cs-137). The driver was unhurt and walked to a local business to report the accident leaving the gauge unattended. The gauge was stolen while the driver was gone. Police were notified and a report filed. The gauge was locked inside of the locked case and chained to the vehicle.

FL report #FL07-001

* * * UPDATE FROM STATE OF FLORIDA (FURNACE) TO HUFFMAN AT 0726 EST ON 1/10/07 * * *

The State reports that a gauge meeting the description of the missing gauge was found by a Polk County representative on the side of a road. The gauge was not in its case but was intact and did not appear to be damaged. The gauge is being stored by the County (which is licensed to possess and use moisture density gauges) in an authorized safe and secure storage location and will be transferred to the licensee today. The licensee plans to send the gauge to a vendor to have it checked-out, leak tested, and certified for use before returning it to service.

R1DO (Bellamy) and NMSS (Morell) have been notified. ILTAB notified by e-mail.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Agreement State
Event Number: 55073
Rep Org: NE DIV OF RADIOACTIVE MATERIALS
Licensee: Church of Jesus Christ of Latter Day Saints
Region: 4
City: Omaha   State: NE
County:
License #: GL0450
Agreement: Y
Docket:
NRC Notified By: Deb Wilson
HQ OPS Officer: Donald Norwood
Notification Date: 01/19/2021
Notification Time: 16:37 [ET]
Event Date: 01/01/2007
Event Time: 00:00 [CST]
Last Update Date: 01/19/2021
Emergency Class: Non Emergency
10 CFR Section:
Agreement State
Person (Organization):
GREG WARNICK (R4DO)
NMSS_EVENTS_NOTIFICATION (EMAIL)
ILTAB (EMAIL)
Event Text
AGREEMENT STATE REPORT - LOST TRITIUM EXIT SIGNS

The following information was received via E-mail:

"The licensee's facility management group was going through their records and inventory. They discovered that six tritium exit signs at the Church in Blair, NE had been replaced with non-tritium signs in 2007. They are unable to find the documentation regarding the signs' disposal and therefore are unable to determine if they were disposed of properly. The building and storage buildings were searched and the signs were not found. Due to the lapse in time and purchase date of 10/25/1993, serial numbers were not available and no further follow-up will be conducted."

Nebraska Item Number: NE210002

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks. For additional information go to http://www-pub.iaea.org/MTCD/publications/PDF/Pub1227_web.pdf