Skip to main content

Event Notification Report for December 28, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
12/27/2006 - 12/28/2006

EVENT NUMBERS
43073430714306743068

General Information or Other
Event Number: 43073
Rep Org: TENNESSEE DIV OF RAD HEALTH
Licensee: METHODIST MEDICAL CENTER OF OAK RIDGE
Region: 1
City: OAK RIDGE   State: TN
County:
License #: R-01083
Agreement: Y
Docket:
NRC Notified By: BILLY FREEMAN
HQ OPS Officer: JASON KOZAL
Notification Date: 01/04/2007
Notification Time: 10:47 [ET]
Event Date: 12/28/2006
Event Time: 07:30 [EST]
Last Update Date: 01/04/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
ANTHONY DIMITRIADIS (R1)
GREG MORELL (NMSS)
Event Text
AGREEMENT STATE REPORT - FAILURE OF SOURCE TO RETRACT INTO AFTERLOADER UNIT

The State provided the following information via facsimile:

"Prior to a scheduled patient treatment, the RSO at Methodist Medical Center was performing QA testing on the Nucletron-Oldelft Corp. Model microSelection-HDR remote afterloading device. The device utilizes a sealed source containing 10 curies of Iridium-192 to be used for treatment of cancer in humans. The sealed source would not retract when the RSO tried the emergency retraction button at the control console. Following the emergency procedures, the RSO manually retracted the sealed source into the HDR afterloader unit. The RSO estimated it took three seconds to return the sealed source to its shielded position. Nucletron Corp. was immediately notified of the malfunction by the RSO. Nucletron Corp. called DRH to request reciprocal recognition of its Maryland license and an authorized service person arrived at the licensee's facility on 12/28/06. The circuit board was found to be faulty and was repaired. After repair, the required safety functions of the system were tested and found to be functioning as designed. The licensee will complete a written report and submit to the State."

Tennessee report number: TN-06-158


Power Reactor
Event Number: 43071
Facility: DUANE ARNOLD
Region: 3     State: IA
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BOB MORELL
HQ OPS Officer: PETE SNYDER
Notification Date: 01/03/2007
Notification Time: 10:14 [ET]
Event Date: 12/28/2006
Event Time: 12:00 [CST]
Last Update Date: 01/03/2007
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
SONIA BURGESS (R3)
OMID TABATABAI (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
POTENTIAL DEGRADATION OF HYDRAULIC SNUBBER FLUID

"FPL Energy Duane Arnold makes the following notification under 10 CFR 21.21(d)(3)(i) of a defect found during snubber rebuild activities. The specific defect is foreign materials identified in the GE SF 1154 snubber fluid, which was supplied by Shaw A/DE, Inc (now known as Fronek Anchor Darling Enterprises, Inc.) as a basic component in 2003. The fluid has been identified as a part of GE batch number AD965 and was manufactured June 2001.

"The foreign material had the appearance and texture of paraffin wax. FPL Energy has postulated that the foreign material could restrict fluid flow through the orifice in the snubber and cause the snubber to remain locked following activation. The resulting locked snubber would prevent the function of allowing for some piping movement associated with normal system movement.

"The fluid has been removed from use at the Duane Arnold Energy Center (DAEC) and a portion was sent for analysis. The analysis indicates that the solid contaminate is silicone. Silicone based oils are generally very stable and the analysis does not indicate how, or why, they came out of solution. FPL Energy engineering personnel inquired about the analysis findings to ascertain the likely causes for the silicone separation from solution. The conclusion is that it could have been a bad batch, a contaminant could have been introduced during processing or repackaging or it could have resulted from some form of reaction with the plastic container.

"The supplier, Fronek Anchor Darling Enterprises, Inc, was contacted on 12/22/06 to discuss FPL Energy Duane Arnold's findings.

"FPL Energy has verified that none of the suspect batch has been installed in snubbers installed at the DAEC. All the suspect fluid has been accounted for."

It is unknown if any fluid from this same lot was distributed to any other power reactor sites.

The licensee notified the NRC Resident Inspector.


Other Nuclear Material
Event Number: 43067
Rep Org: KAKIVIK ASSET MANAGEMENT
Licensee: KAKIVIK ASSET MANAGEMENT
Region: 4
City: KUPARUK   State: AK
County:
License #: 50-27667-01
Agreement: N
Docket:
NRC Notified By: JEFF ARVESON
HQ OPS Officer: JASON KOZAL
Notification Date: 12/28/2006
Notification Time: 11:43 [ET]
Event Date: 12/28/2006
Event Time: 02:30 [YST]
Last Update Date: 12/28/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
THOMAS FARNHOLTZ (R4)
SANDRA WASTLER (NMSS)
Event Text
FAILURE OF RADIOGRAPHY CAMERA SOURCE TO FULLY RETRACT

On December 28, 2006, at about 2:30 am local time, while performing a radiography at the pumping facility in Kuparuk, Alaska, the radiography camera source failed to fully retract into the shielded position. The radiographer contacted the Radiation Safety Officer who guided the radiographer in unscrewing the drive cables so that the source was able to be fully retracted. No over-exposures or unplanned exposures occurred.

The camera is a INC Model IR-100. The original source strength of the radiography camera Ir-192 source was 100 curies. Kakivik Asset Management plans to contact the manufacturer of the camera about this occurrence.


General Information
Event Number: 43068
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: NINYO AND MOORE
Region: 4
City: SAN JACINTO   State: CA
County:
License #: 5073-30
Agreement: Y
Docket:
NRC Notified By: BARBARA HAMRICK
HQ OPS Officer: PETE SNYDER
Notification Date: 12/29/2006
Notification Time: 16:13 [ET]
Event Date: 12/28/2006
Event Time: 18:30 [PST]
Last Update Date: 01/30/2013
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
THOMAS FARNHOLTZ (R4)
KEITH McCONNELL (NMSS)
ILTAB (via e-mail)
MEXICO CNSNS
Event Text
AGREEMENT STATE REPORT - THEFT OF A TROXLER MOISTURE DENSITY GAUGE

"On December 29, 2006, at 11:10 am, the licensee contacted the California [Radiologic Health Branch] RHB to report the theft of a Troxler, Model 3430 moisture/density gauge (S/N 38217) containing a nominal 10 millicuries Cs-137 and nominal 40 millicuries Am-241. When the licensee initially reported, they had been informed by their technician that the gauge (secured by two locking cables in the truck bed) had been stolen at 11:00 am on December 29, 2006, while the technician was having lunch at a restaurant in Fontana, CA. Subsequently, during the police investigation, the technician acknowledged that the gauge had actually been stolen out of his truck, sometime the night previously (i.e., between about 6:30 pm December 28, 2006 and 8:00 am December 29, 2006), while the truck was parked in front of his home in San Jacinto, CA.

"The licensee prohibits their technicians from taking the gauges home overnight, and intends to take disciplinary action against the technician in this regard. The San Jacinto police have also been contacted, and the licensee intends to place a reward notification in the local press in the San Jacinto area. RHB will continue to follow up on this matter."

* * * UPDATE FROM DONELLE KRAJEWSKI TO CHARLES TEAL ON 1/30/13 AT 1351 EST * * *

The following was received via email from the State of California via email:

"On Monday, January 28, 2013, the Border Patrol notified us, the Texas Department of State Health Services (DSHS), that a trailer had caused the radiation monitor to alarm at its checkpoint in Sierra Blanca, TX (approximately 90 miles east of El Paso on I-10).

"The individual pulling the trailer stated he was moving to Texas from California. The source of radiation was identified as being a Troxler moisture/density gauge. [The individual] stated that he had purchased the gauge as a tool for finding underground pipe at a swap-meet in Beaumont, CA, back in late August/early September of 2012 (he paid $125 or $150 for it). He stated he had not used the gauge he had only opened the case and looked at it and then put it in his storage shed where it remained until he packed up to move. The gauge was detained by one of our Agency [DSHS] inspectors and [the individual] willingly surrendered it.

"Gauge information:

"Troxler Model 3430
"SN: 38217

"It, and the case, are in very good condition. Based on isotope identification by Border Patrol and the DSHS inspector, it appears that the cesium-137 and the americium-241/beryllium sources are still in the gauge."

Notified R4DO (Walker), Mexico, and FSME Event Resource via email.


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.