Skip to main content

Event Notification Report for November 15, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/14/2006 - 11/15/2006

EVENT NUMBERS
4299742993

General Information or Other
Event Number: 42997
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: SCHLUMBERGER
Region: 4
City: ZAPATA   State: TX
County:
License #:
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: BILL GOTT
Notification Date: 11/16/2006
Notification Time: 08:54 [ET]
Event Date: 11/15/2006
Event Time: 21:30 [CST]
Last Update Date: 11/17/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CLAUDE JOHNSON (R4)
GREG MORELL (NMSS)
ILTAB VIA EMAIL
MEXICO VIA EMAIL
Event Text
MISSING WELL LOGGING TOOL

At 2130 CST on 11/15/06, Schlumberger reported that a well logging tool was missing from the truck transporting the tool. The tool contained 1.5 curies of Tritium in a neutron target. It appears that the tool was lost or fell from the truck along a 50 mile portion of County Road 3169 in Zapata County, TX. A search for the tool is in progress.

* * * UPDATE VIA E-MAIL FROM TEXAS (JISHA) TO HUFFMAN AT 1630 EST ON 11/16/06 * * *

"At 2130 on Nov 15, 2006, a third party transport driver noted that he was missing a well logging tool that contains a neutron generator. The tool appears to have fallen off the truck along a fifty mile stretch of county road 3169 in Zapata county. The neutron generator contains 1.5 curies of tritium that is impregnated into the target of tube and is sealed within the tube and tool. No radiation is emitted by the generator and no public exposure is expected.

"Schlumberger personnel are searching the fifty miles of road and if the tool is not located on the first search, the Zapata county sheriff's office will be contacted. The search will continue at daylight. Additional notifications have been made to the Nuclear Regulatory Commission (NRC), U.S. Department of Transportation (DOT), and State Operations Center (SOC). The tool is a model 7158 manufactured by Schlumberger and is ~10 feet in length with an outside diameter of one and 11/16 inches. The device is made of stainless steel and has few markings on the exterior surface. The external surface of each neutron generator target is engraved with a target assembly I.D. number consisting of year-month-day (date of construction) and target position and the sequential serial number assigned to the neutron generator. After tritiation, the neutron generators have the model number (758, 761, or 762) and 'Radioactive H3' etched or engraved on the annulus of the end Kovar piece at the pinchoff end. The remaining annular space is taken by a second engraving of the serial number.

"Specific Item Missing: 1 11/16 inches OD logging tool continuing neutron generator approximately 108 inches (9 feet) long. The tool is made of steel and is cylindrical. Neutron Generator: Schlumberger Model 7158 covered by SSDR NR-316-D-101-S-1 (attached), Serial Number, 5710
Activity and Nuclide: 1.5 curies of tritium

"Description: Tritium is impregnated in a metal target contained within a sealed tube. The tube is sealed within an electronic housing (PNG-1032) and this electronic housing is contained with a well logging tool that is sealed and pressure rated to 15,000 psi."

The generator only produces neutron radiation when high voltage is applied.

R4DO (Johnson) and NMSS EO (Camper) notified. ILTAB notified via e-mail.

* * * UPDATE VIA E-MAIL FROM TEXAS (JISHA) TO GOTT AT 0831 EST ON 11/17/06 * * *

On 11/16/06, the licensee found the tool with the source intact, and it is reportedly at their Laredo facility.

Notified R4DO (C. Johnson) and NMSS (G. Morell) and emailed to ILTAB.


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Power Reactor
Event Number: 42993
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: BRIAN ROKES
HQ OPS Officer: JEFF ROTTON
Notification Date: 11/15/2006
Notification Time: 16:26 [ET]
Event Date: 11/15/2006
Event Time: 14:00 [EST]
Last Update Date: 11/15/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
PAMELA HENDERSON (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP DURING ELECTRICAL MAIN GENERATOR TROUBLESHOOTING

"On November 15, 2006, at 14:00 hours, an automatic reactor trip occurred during troubleshooting of the Main Generator Exciter Generrex power supply, when an electrical spike resulted in a turbine trip which caused a reactor trip. All control rods fully inserted and safety equipment operated as expected. The Auxiliary Feedwater (AFW) System actuated as expected as a result of a low steam generator level from the reactor trip and started the motor driven AFW pumps. The Emergency Diesel Generators did not start as offsite power remained available. The plant was stabilized in hot standby with decay heat being removed by the main condenser. There were no radiation releases. The condition is under investigation and a post trip review is being conducted."

No PORVs or SG safety valves lifted during the event. The electrical plant is in a normal shutdown lineup and the EDGs are operable in standby. There was no affect on Unit 3 operation due to this event.

The licensee notified the NRC Resident Inspector, and stated that IPEC communications has transmitted an IPEC Status Report which provides a status to local, state, and federal agencies.