Event Notification Report for October 01, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/30/2006 - 10/01/2006
Power Reactor
Event Number: 42869
Facility: BEAVER VALLEY
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: KEN TIEFENTHAL
HQ OPS Officer: JASON KOZAL
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: KEN TIEFENTHAL
HQ OPS Officer: JASON KOZAL
Notification Date: 10/01/2006
Notification Time: 15:24 [ET]
Event Date: 10/01/2006
Event Time: 08:35 [EDT]
Last Update Date: 10/01/2006
Notification Time: 15:24 [ET]
Event Date: 10/01/2006
Event Time: 08:35 [EDT]
Last Update Date: 10/01/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(3)(v)(C) - POT UNCNTRL RAD REL 50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
CHRIS HOTT (R1)
CHRIS HOTT (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 60 | Power Operation | 60 | Power Operation |
TEMPORARY SCAFFOLDING FOR UPCOMING OUTAGE RENDERS 'A' AND 'B' MSIV INOPERABLE
"Scaffold that was built for upcoming refueling outage work at Beaver Valley Power Station Unit 2 may have prevented two Main Steam Isolation Valves (MSIV) from reaching the full closed position.
"Scaffold was built on 9/29/06 and 9/30/06 for refueling outage work on the 'A' and 'B' MSIV's. The 'C' MSIV was not impacted. Some of the seismic bracing for these scaffolds were in the area of travel when closing the MSIV's. There is reasonable assurance these braces would have prevented the 'A' and ' B' MSIV's from reaching the full closed position. During a Steam Generator Tube Rupture accident, this MSIV interference may have prevented accident mitigation by not allowing the MSIV to properly close and cause additional release of radioactive material to the environment beyond that already analyzed in the Updated Final Safety Analysis Report.
"On 10/1/06 at 0835 the MSIV inoperability was discovered and Technical Specification 3.7.1.5 (MSIV Operability) and 3.0.3 were entered. The scaffold bracing was moved out of the valve closure path of the 'B' MSIV and at 0915 Technical Specification 3.0.3 was exited. At 0945 the 'A' MSIV was free to close and Technical Specification 3.7.1.5 was exited. This is being reported as a loss of a safety function for a Main Steam Line Isolation Valve which is required to control the release of radioactive material, and which is required to mitigate the consequences of an accident, pursuant to 10 CFR 50.72(b)(3)(v)(C) and 50.72(b)(3)(v)(D).
"Unit power remained constant throughout the event and no other safety systems have been compromised."
The licensee is currently lowering power for the Unit 2 refueling outage.
The licensee notified the NRC Resident Inspector.
"Scaffold that was built for upcoming refueling outage work at Beaver Valley Power Station Unit 2 may have prevented two Main Steam Isolation Valves (MSIV) from reaching the full closed position.
"Scaffold was built on 9/29/06 and 9/30/06 for refueling outage work on the 'A' and 'B' MSIV's. The 'C' MSIV was not impacted. Some of the seismic bracing for these scaffolds were in the area of travel when closing the MSIV's. There is reasonable assurance these braces would have prevented the 'A' and ' B' MSIV's from reaching the full closed position. During a Steam Generator Tube Rupture accident, this MSIV interference may have prevented accident mitigation by not allowing the MSIV to properly close and cause additional release of radioactive material to the environment beyond that already analyzed in the Updated Final Safety Analysis Report.
"On 10/1/06 at 0835 the MSIV inoperability was discovered and Technical Specification 3.7.1.5 (MSIV Operability) and 3.0.3 were entered. The scaffold bracing was moved out of the valve closure path of the 'B' MSIV and at 0915 Technical Specification 3.0.3 was exited. At 0945 the 'A' MSIV was free to close and Technical Specification 3.7.1.5 was exited. This is being reported as a loss of a safety function for a Main Steam Line Isolation Valve which is required to control the release of radioactive material, and which is required to mitigate the consequences of an accident, pursuant to 10 CFR 50.72(b)(3)(v)(C) and 50.72(b)(3)(v)(D).
"Unit power remained constant throughout the event and no other safety systems have been compromised."
The licensee is currently lowering power for the Unit 2 refueling outage.
The licensee notified the NRC Resident Inspector.
General Information or Other
Event Number: 46027
Rep Org: KANSAS DEPT OF HEALTH & ENVIRONMENT
Licensee: WESLEY MEDICAL CENTER
Region: 4
City: WICHITA State: KS
County:
License #: 19-C041-01
Agreement: Y
Docket:
NRC Notified By: DAVID WHITFILL
HQ OPS Officer: DONG HWA PARK
Licensee: WESLEY MEDICAL CENTER
Region: 4
City: WICHITA State: KS
County:
License #: 19-C041-01
Agreement: Y
Docket:
NRC Notified By: DAVID WHITFILL
HQ OPS Officer: DONG HWA PARK
Notification Date: 06/18/2010
Notification Time: 17:13 [ET]
Event Date: 10/01/2006
Event Time: 00:00 [CDT]
Last Update Date: 06/18/2010
Notification Time: 17:13 [ET]
Event Date: 10/01/2006
Event Time: 00:00 [CDT]
Last Update Date: 06/18/2010
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
WILLIAM JONES (R4DO)
BRUCE WATSON (FSME)
WILLIAM JONES (R4DO)
BRUCE WATSON (FSME)
AGREEMENT STATE REPORT - FOUND BRACHYTHERAPHY SOURCE PREVIOUSLY LOST
The State of Kansas provided the following information via facsimile:
"This event that occurred during the 4th quarter of 2006 at Wesley Medical Center, LLC, was determined during the State of Kansas IMPEP [Integrated Materials Performance Evaluation Program] inspection conducted the week of June 14, 2010, to be reportable under 10CFR2201. An electronic update to the NMED database will follow. Below are details of the event.
"During an inspection by KDHE [Kansas Department of Health and Environment] of Wesley Medical Center 2/14/2007, a review of the 4th quarter Radiation Safety Committee notes revealed that a brachytherapy source was lost for approximately 45 hours. From the inspector's notes: 'Incident where a Cs-137 brachytherapy source was lost for approximately 45 hours before being found in the sheets in the laundry room by the RSO [Radiation Safety Officer]. RSO did not make a determination of exposure to the patient based on conservative and worst case scenarios. Incident was not reported to the State.'
"The RSO notes read: 'We had one recordable event that has been noted in the HNS system. We had one misplaced cesium 137 brachytherapy source. A patient presented for treatment of cervix cancer and we used low-dose Fletcher Suit system where the cesium sources dwell within the patient for 45 hours. The plan was reviewed and the patient was loaded. On the day of removal, one source was missing when the RSO emptied the tandems. Both physicists searched extensively for the source using a Geiger counter. The source was located on the floor in the laundry capture room for women's health. It was determined that the source never reached its destination in the patient, and that it most likely fell into the bed linens during insertion. One environmental service worker spends approximately five minutes per day having an approximate exposure of 1 mRem from that activity. A member of the public would be limited to 100 mRem of exposure per year and the exposure rate would be approximately 1.2 mRem per hour at 3 meters; some of the walls in the room are cinder blocks which provide some shielding. It was suggested that linen be left in the patient's room during their stay to guard against having an incident such as this in the future.'
"The licensee was issued a citation for failure to report this as a lost source.
"Update information provided during the week of June 14, 2010 indicated that the source activity was 37 mCi (15 mg Ra equivalent)."
KS Event No.: KS100006.
The State of Kansas provided the following information via facsimile:
"This event that occurred during the 4th quarter of 2006 at Wesley Medical Center, LLC, was determined during the State of Kansas IMPEP [Integrated Materials Performance Evaluation Program] inspection conducted the week of June 14, 2010, to be reportable under 10CFR2201. An electronic update to the NMED database will follow. Below are details of the event.
"During an inspection by KDHE [Kansas Department of Health and Environment] of Wesley Medical Center 2/14/2007, a review of the 4th quarter Radiation Safety Committee notes revealed that a brachytherapy source was lost for approximately 45 hours. From the inspector's notes: 'Incident where a Cs-137 brachytherapy source was lost for approximately 45 hours before being found in the sheets in the laundry room by the RSO [Radiation Safety Officer]. RSO did not make a determination of exposure to the patient based on conservative and worst case scenarios. Incident was not reported to the State.'
"The RSO notes read: 'We had one recordable event that has been noted in the HNS system. We had one misplaced cesium 137 brachytherapy source. A patient presented for treatment of cervix cancer and we used low-dose Fletcher Suit system where the cesium sources dwell within the patient for 45 hours. The plan was reviewed and the patient was loaded. On the day of removal, one source was missing when the RSO emptied the tandems. Both physicists searched extensively for the source using a Geiger counter. The source was located on the floor in the laundry capture room for women's health. It was determined that the source never reached its destination in the patient, and that it most likely fell into the bed linens during insertion. One environmental service worker spends approximately five minutes per day having an approximate exposure of 1 mRem from that activity. A member of the public would be limited to 100 mRem of exposure per year and the exposure rate would be approximately 1.2 mRem per hour at 3 meters; some of the walls in the room are cinder blocks which provide some shielding. It was suggested that linen be left in the patient's room during their stay to guard against having an incident such as this in the future.'
"The licensee was issued a citation for failure to report this as a lost source.
"Update information provided during the week of June 14, 2010 indicated that the source activity was 37 mCi (15 mg Ra equivalent)."
KS Event No.: KS100006.