Event Notification Report for September 20, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
09/19/2006 - 09/20/2006
General Information or Other
Event Number: 42851
Rep Org: IOWA DEPARTMENT OF PUBLIC HEALTH
Licensee: UNIVERSITY OF IOWA
Region: 3
City: IOWA CITY State: IA
County: JEFFERSON
License #: 0037-1-52-AAB
Agreement: Y
Docket:
NRC Notified By: DAN MCGHEE
HQ OPS Officer: JASON KOZAL
Licensee: UNIVERSITY OF IOWA
Region: 3
City: IOWA CITY State: IA
County: JEFFERSON
License #: 0037-1-52-AAB
Agreement: Y
Docket:
NRC Notified By: DAN MCGHEE
HQ OPS Officer: JASON KOZAL
Notification Date: 09/20/2006
Notification Time: 17:17 [ET]
Event Date: 09/20/2006
Event Time: 00:00 [CDT]
Last Update Date: 09/21/2006
Notification Time: 17:17 [ET]
Event Date: 09/20/2006
Event Time: 00:00 [CDT]
Last Update Date: 09/21/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JULIO LARA (R3)
JOSEPH HOLONICH (NMSS)
JULIO LARA (R3)
JOSEPH HOLONICH (NMSS)
IRRADIATOR SOURCE TEMPORARILY STUCK IN THE EXPOSED POSITION
On the night of 8/28- 8/29/2006 the large irradiator was being used for an all night procedure. The principle investigator for the irradiator was present to conclude the operation on the morning of August 29. At the time designated for source retraction, the irradiator source in fact did not retract to the stowed position. The source actuation system uses air pressure to expose the source and spring force to stow the source. The principle investigator tried to house the source by operating the "override" button. The source remained exposed. After approximately 15 minutes the source returned to the housed condition with no operator action. The irradiator will not be used until J.L. Shepard [the manufacturer] is contacted and the cause identified and corrected. The source is currently stowed.
The irradiator is an 8800 Curie Cs-137 self shielded irradiator.
Iowa event number I806004
The state notified Region 3 (Lynch).
* * * Update on 09/21/06 at 1510 ET from Randy D' Ahlin to MacKinnon * * *
The following updated information was called in by the State of Iowa Department of Public Health:
The irradiator type is an open beam irradiator. The irradiator has been repaired, tested and placed back in service on 09/21/06.
R3DO (Julio Lara) and NMSS EO (Cindy Flannery) notified.
On the night of 8/28- 8/29/2006 the large irradiator was being used for an all night procedure. The principle investigator for the irradiator was present to conclude the operation on the morning of August 29. At the time designated for source retraction, the irradiator source in fact did not retract to the stowed position. The source actuation system uses air pressure to expose the source and spring force to stow the source. The principle investigator tried to house the source by operating the "override" button. The source remained exposed. After approximately 15 minutes the source returned to the housed condition with no operator action. The irradiator will not be used until J.L. Shepard [the manufacturer] is contacted and the cause identified and corrected. The source is currently stowed.
The irradiator is an 8800 Curie Cs-137 self shielded irradiator.
Iowa event number I806004
The state notified Region 3 (Lynch).
* * * Update on 09/21/06 at 1510 ET from Randy D' Ahlin to MacKinnon * * *
The following updated information was called in by the State of Iowa Department of Public Health:
The irradiator type is an open beam irradiator. The irradiator has been repaired, tested and placed back in service on 09/21/06.
R3DO (Julio Lara) and NMSS EO (Cindy Flannery) notified.
General Information or Other
Event Number: 42987
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: PRECISION ENERGY SERVICES
Region: 4
City: DESOTO PARISH State: LA
County:
License #: LA-4413-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JOE O'HARA
Licensee: PRECISION ENERGY SERVICES
Region: 4
City: DESOTO PARISH State: LA
County:
License #: LA-4413-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JOE O'HARA
Notification Date: 11/13/2006
Notification Time: 09:50 [ET]
Event Date: 09/20/2006
Event Time: 00:00 [CST]
Last Update Date: 11/13/2006
Notification Time: 09:50 [ET]
Event Date: 09/20/2006
Event Time: 00:00 [CST]
Last Update Date: 11/13/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JEFFREY CLARK (R4)
GREG MORELL (NMSS)
JEFFREY CLARK (R4)
GREG MORELL (NMSS)
AGREEMENT STATE REPORT - ABANDONED SOURCE
The state provided the following information via fax:
"Precision Energy Services abandoned a 2 Ci source of Cs-137 (serial number 06926B) down a hole at a depth of 3064 feet. The tool string got stuck on September 20, 2006. The first attempt to retrieve the stuck tool string succeeded in retrieving the Am/Be neutron source but also caused the tools to break apart. The section of the tool string with the Cs-137 source was stuck at a depth of 3064 feet. Red-dyed cement plug was set with open-ended drill pipe at 3060 feet to 2860 feet. Production casing was run and cemented at 2850 feet, with float shoe, 41 feet of cement filled shoe joint, and float collar. The deflection device was dropped on the float collar and 20 feet of red-dyed cement was dumped on the device on November 1, 2006. An identification plaque will be placed on the well."
The state provided the following information via fax:
"Precision Energy Services abandoned a 2 Ci source of Cs-137 (serial number 06926B) down a hole at a depth of 3064 feet. The tool string got stuck on September 20, 2006. The first attempt to retrieve the stuck tool string succeeded in retrieving the Am/Be neutron source but also caused the tools to break apart. The section of the tool string with the Cs-137 source was stuck at a depth of 3064 feet. Red-dyed cement plug was set with open-ended drill pipe at 3060 feet to 2860 feet. Production casing was run and cemented at 2850 feet, with float shoe, 41 feet of cement filled shoe joint, and float collar. The deflection device was dropped on the float collar and 20 feet of red-dyed cement was dumped on the device on November 1, 2006. An identification plaque will be placed on the well."