Event Number: 42873
Facility: CATAWBA
Region: 2     State: SC
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: TOMAS GARRISON
HQ OPS Officer: JASON KOZAL
Notification Date: 10/03/2006
Notification Time: 15:40 [ET]
Event Date: 08/08/2006
Event Time: 16:17 [EDT]
Last Update Date: 10/03/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
THOMAS DECKER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
60 DAY REPORT - INVALID ACTUATION OF AUXILIARY FEED PUMP 2B

"This 60-day report as allowed by 10 CFR 50.73 (a)(2)(iv)(A) to describe an invalid actuation of a specified system, specifically the Auxiliary Feedwater System (AFW). This event involved an invalid actuation of the Motor Driven Auxiliary Feedwater pump 2B during routine Unit 2 Auxiliary Safeguards Testing on 8/8/06. The system was properly aligned and did inject water into Steam Generators 2C and 2D as designed to perform a complete actuation of AFW pump 2B.

"The motor driven auxiliary feedwater pumps will automatically start and provide the minimum required feedwater flow within one minute following any of these conditions:

"1. Two out of four low-low level alarms in any one of the four steam generators.

"2. Loss of both main feedwater pumps

"3. Initiation of safety injection signal

"4. Loss of station normal auxiliary electric power

"5. AMSAC signal

"Since none of the five auto-start parameters were met at the time of the system actuation the signal was determined to be invalid.

"Engineering reviewed the CA Pump Start circuit to determine which equipment failures could cause the switchgear breaker for the AFW Pump 2B to close and start the pump. These included reviewing sequencer start signals, manual pushbuttons, and associated contacts and breakers. The failure of the fluke meter used during the testing was considered, also. In addition, the Operations Test Group performed an analysis of the human performance aspects of this testing. Based on these investigations potential equipment failures have been ruled out and based on the correspondence in time with when the inadvertent start occurred and when the meter reading was taken, it is believed that the inadvertent start is due to an anomaly with the Fluke 189 meter or issues when taking the measurement. The measurement is taken across an energized circuit, which can be susceptible to inadvertent actuations. The test procedure has been revised to open links on the circuit to prevent inadvertent operation."

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 42775
Rep Org: MA RADIATION CONTROL PROGRAM
Licensee: QSA GLOBAL, INC
Region: 1
City: BURLINGTON   State: MA
County:
License #: 12-8361
Agreement: Y
Docket:
NRC Notified By: MIKE WHALEN
HQ OPS Officer: BILL GOTT
Notification Date: 08/15/2006
Notification Time: 14:33 [ET]
Event Date: 08/08/2006
Event Time: 00:00 [EDT]
Last Update Date: 08/15/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RAYMOND LORSON (R1)
BLAIR SPITZBERG (R4)
CINDY FLANNERY (NMSS)
Event Text
AGREEMENT STATE REPORT - SURFACE CONTAMINATION

The State provided the following information via email:

"Licensee received an 'empty' lead pod with exterior contamination of 1.3 E-5 microCi/cm2. Contamination identified as Cs-137. Shipment came from Thermo Electron, 1410 Gillingham Lane, Sugarland, Texas via Conway Trucking."

"Licensee informed Conway Trucking of the contamination."


Power Reactor
Event Number: 42755
Facility: VERMONT YANKEE
Region: 1     State: VT
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: MICHEAL PLETCHER
HQ OPS Officer: JEFF ROTTON
Notification Date: 08/08/2006
Notification Time: 17:40 [ET]
Event Date: 08/08/2006
Event Time: 16:45 [EDT]
Last Update Date: 08/08/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
JOHN CARUSO (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF EMERGENCY RESPONSE RADIO ALERT SYSTEM TRANSMITTER

Licensee has experienced a loss of emergency response capability due to loss of the Ames Hill NOAA transmitter. This transmitter is used to transmit information to the radio alert system (weather alert) for the site. Contract vendor has been contacted for troubleshooting and repair and is enroute to investigate the problem. The site has the ability to use the local radio stations if necessary.

The licensee has notified the NRC Resident Inspector. The licensee will be notifying the VT, NH, and MA State Police, the VT Department of Public Service, and the VT Emergency Management Office.

* * * UPDATE FROM J. BROOKS TO W. GOTT AT 1905 ON 08/08/06 * * *

At 1840, Vermont Yankee was notified that the Ames Hill NOAA transmitter was operational. The cause of the failure was due to a possible lightning strike.

The licensee notified the NRC Resident Inspector. The licensee will be notifying the VT, NH, and MA State Police, the VT Department of Public Service, and the VT Emergency Management Office.

Notified R1DO (J Caruso).


General Information or Other
Event Number: 42756
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: RMA GEOSCIENCE
Region: 4
City: CHINO   State: CA
County: SAN BERNARDINO
License #: 6384-30
Agreement: Y
Docket:
NRC Notified By: CJ SALGADO
HQ OPS Officer: BILL GOTT
Notification Date: 08/08/2006
Notification Time: 18:17 [ET]
Event Date: 08/08/2006
Event Time: 05:00 [PDT]
Last Update Date: 08/09/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RUSSELL BYWATER (R4)
PATRICIA HOLAHAN (NMSS)
ILTAB VIA EMAIL
MEXICO VIA EMAIL
Event Text
STOLEN MOISTURE DENSITY GAUGE

After picking up the CPN Model MC-3 Moisture Density Gauge (s/n M38128625 10 millicuries Cs-137 and 50 millicuries Am-241:Be) at the company's office in Chino, CA, the gauge operator stopped at his residence in Victorville, CA, for 20 to 30 minutes. The operator's residence is on the way to the job site. The gauge was chained to the bed of the company truck which was parked in the operator's personal stall. When the operator returned to his truck the two chains that secured the gauge case to the truck were cut, and the gauge and case were gone. The San Bernardino Sheriff's Office was notified and investigated. The Radiation Safety Officer is preparing a reward offer. The gauge was within its leak test interval, and the last test was satisfactory.

* * * UPDATE ON 8/9/2006 AT 0001 FROM BARBARA HAMRICK TO ABRAMOVITZ * * *

The State provided the following information via email:

"Today at about 6:15 pm, the California Radiologic Health Branch reported that a moisture-density gauge had been stolen in Victorville, CA this morning. The gauge belonged to RMA Geoscience. We are happy to report, the gauge was found tonight intact, in an abandoned field in Victorville, by the Victorville Fire Department. The RSO was contacted, and will be retrieving the gauge tonight, and returning it to the authorized permanent storage location in Chino, CA."

Notified NMSS (Holahan), ILTAB, R1DO (Bywater) and Mexico (via E-mail).


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Power Reactor
Event Number: 42757
Facility: SOUTH TEXAS
Region: 4     State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: WAYNE HARRISON
HQ OPS Officer: JEFF ROTTON
Notification Date: 08/08/2006
Notification Time: 18:39 [ET]
Event Date: 08/08/2006
Event Time: 15:43 [CDT]
Last Update Date: 08/08/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
RUSSELL BYWATER (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
INADVERTENT EMERGENCY NOTIFICATION SIREN ACTIVATION

"At approximately 15:43 [CDT] on 8/8/2006, all STP Emergency Notification System (ENS) sirens inadvertently/spuriously activated. The sirens automatically secured after approximately 3 minutes. All sirens except one at El Maton have subsequently been polled operable. STPNOC is investigating the cause of the activation.

"STPNOC has notified Matagorda County Sheriff Department and radio station KZRC. Inquiries from the public have been received.

"This notification is being made under 10CFR50.72(b)(2)(xi) as an event where other government agencies were notified."

The licensee notified the NRC Resident Inspector.