Event Notification Report for July 08, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/07/2006 - 07/08/2006
Other Nuclear Material
Event Number: 42705
Rep Org: CONSTRUCTION ENGINEERING CONSULTANT
Licensee: CONSTRUCTION ENGINEERING CONSULTANTS INC.
Region: 1
City: LEETSDALE State: PA
County:
License #: 38-18456-02
Agreement: N
Docket:
NRC Notified By: DAVE MITRICK
HQ OPS Officer: PETE SNYDER
Licensee: CONSTRUCTION ENGINEERING CONSULTANTS INC.
Region: 1
City: LEETSDALE State: PA
County:
License #: 38-18456-02
Agreement: N
Docket:
NRC Notified By: DAVE MITRICK
HQ OPS Officer: PETE SNYDER
Notification Date: 07/14/2006
Notification Time: 14:23 [ET]
Event Date: 07/08/2006
Event Time: 14:00 [EDT]
Last Update Date: 07/14/2006
Notification Time: 14:23 [ET]
Event Date: 07/08/2006
Event Time: 14:00 [EDT]
Last Update Date: 07/14/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
GLENN MEYER (R1)
THOMAS ESSIG (NMSS)
GLENN MEYER (R1)
THOMAS ESSIG (NMSS)
DAMAGED TROXLER MOISTURE DENSITY GAUGE
The Radiation Safety Officer (RSO) of Construction Engineering Consultants Inc. called to report a damaged Troxler gauge. The damage occurred on 7/8/06 as a backhoe's bucket bent the handle of the gauge. At the time the gauge was retracted and not actively in-use. The individual at the site called the RSO who retrieved the device.
The RSO surveyed the gauge. No leakage was found. The RSO returned the instrument to the storage vault. He resurveyed again later and still could find no leakage. With the damaged handle the gauge cannot function so the RSO is going to send the damage gage to the manufacturer for repair.
The gauge is a Troxler Model 3411B, Serial Number 13844.
The Radiation Safety Officer (RSO) of Construction Engineering Consultants Inc. called to report a damaged Troxler gauge. The damage occurred on 7/8/06 as a backhoe's bucket bent the handle of the gauge. At the time the gauge was retracted and not actively in-use. The individual at the site called the RSO who retrieved the device.
The RSO surveyed the gauge. No leakage was found. The RSO returned the instrument to the storage vault. He resurveyed again later and still could find no leakage. With the damaged handle the gauge cannot function so the RSO is going to send the damage gage to the manufacturer for repair.
The gauge is a Troxler Model 3411B, Serial Number 13844.
Power Reactor
Event Number: 42693
Facility: PERRY
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT KIDDER
HQ OPS Officer: BILL GOTT
Region: 3 State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT KIDDER
HQ OPS Officer: BILL GOTT
Notification Date: 07/08/2006
Notification Time: 09:22 [ET]
Event Date: 07/08/2006
Event Time: 09:18 [EDT]
Last Update Date: 07/11/2006
Notification Time: 09:22 [ET]
Event Date: 07/08/2006
Event Time: 09:18 [EDT]
Last Update Date: 07/11/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
KENNETH RIEMER (R3)
KENNETH RIEMER (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 66 | Power Operation | 66 | Power Operation |
OFFSITE NOTIFICATION - EXCEEDED LIMIT FOR SUSPENDED SOLIDS IN DISCHARGE
"On 6/29/06 at 1630 Neutralization Basin A was pumped to Lake Erie. On 7/7/06 the analysis of suspended solids for this discharge was completed with results outside of the daily limit. Results for the suspended solids for the basin discharge was 142 ppm with a limit of 100 ppm. State of Ohio EPA was notified for this non-compliance. This 4 hour notification is being made due to the notification to the State of Ohio EPA. Notification to the Ohio EPA was made at 0918 on 7/08/06. Specific. Reporting details required by Part 12.A are as follows:
"Discharge occurred- 6/29/06 at 16:30; Discovered 7/7/06 at 14:38 (analysis reported by First Energy Beta Drive Lab)
Approximate amount 18,300 gallons; 7.94 Ph; 142 ppm Total Suspended Solids [backup sample 148 ppm]"
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1007 EDT ON 7/11/06 FROM JIM CASE TO S. SANDIN * * *
"This 4 hour notification is being made due to the additional notification to the State of Ohio EPA.
"This was follow-up information regarding event number 42693 ('Offsite Notification - exceeded limit for suspended solids in discharge'). On 7/10/06 final data analysis for NPDES Monthly Report was obtained and the 6/29/06 exceedance resulted in an exceedance in the monthly average of total suspended solids (TSS). Results for monthly average suspended solids were 44.2 ppm with a limit of 30 ppm. State of Ohio EPA was notified of this non-compliance at 0925 on 7/11/06."
The licensee informed the NRC Resident Inspector. Notified R3DO (Steve Orth).
"On 6/29/06 at 1630 Neutralization Basin A was pumped to Lake Erie. On 7/7/06 the analysis of suspended solids for this discharge was completed with results outside of the daily limit. Results for the suspended solids for the basin discharge was 142 ppm with a limit of 100 ppm. State of Ohio EPA was notified for this non-compliance. This 4 hour notification is being made due to the notification to the State of Ohio EPA. Notification to the Ohio EPA was made at 0918 on 7/08/06. Specific. Reporting details required by Part 12.A are as follows:
"Discharge occurred- 6/29/06 at 16:30; Discovered 7/7/06 at 14:38 (analysis reported by First Energy Beta Drive Lab)
Approximate amount 18,300 gallons; 7.94 Ph; 142 ppm Total Suspended Solids [backup sample 148 ppm]"
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1007 EDT ON 7/11/06 FROM JIM CASE TO S. SANDIN * * *
"This 4 hour notification is being made due to the additional notification to the State of Ohio EPA.
"This was follow-up information regarding event number 42693 ('Offsite Notification - exceeded limit for suspended solids in discharge'). On 7/10/06 final data analysis for NPDES Monthly Report was obtained and the 6/29/06 exceedance resulted in an exceedance in the monthly average of total suspended solids (TSS). Results for monthly average suspended solids were 44.2 ppm with a limit of 30 ppm. State of Ohio EPA was notified of this non-compliance at 0925 on 7/11/06."
The licensee informed the NRC Resident Inspector. Notified R3DO (Steve Orth).
General Information or Other
Event Number: 42694
Rep Org: NC DIV OF RADIATION PROTECTION
Licensee: APAC, ATLANTIC, INC.
Region: 1
City: HICKORY State: NC
County:
License #: 018-0967-3
Agreement: Y
Docket:
NRC Notified By: GRANT MILLS
HQ OPS Officer: STEVE SANDIN
Licensee: APAC, ATLANTIC, INC.
Region: 1
City: HICKORY State: NC
County:
License #: 018-0967-3
Agreement: Y
Docket:
NRC Notified By: GRANT MILLS
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/08/2006
Notification Time: 22:00 [ET]
Event Date: 07/08/2006
Event Time: 05:00 [EDT]
Last Update Date: 07/10/2006
Notification Time: 22:00 [ET]
Event Date: 07/08/2006
Event Time: 05:00 [EDT]
Last Update Date: 07/10/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
PAMELA HENDERSON (R1)
E. WILLIAM BRACH (NMSS)
ILTAB (e-mailed) (NSIR)
PAMELA HENDERSON (R1)
E. WILLIAM BRACH (NMSS)
ILTAB (e-mailed) (NSIR)
AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER MOISTURE DENSITY GAUGE
The following information was received via fax:
"Licensee: APAC Atlantic, Inc, Asheville Division / Hickory Branch
"Event Date &Time: 08 July 2006 between 02:00 and 05:00 am
"Report Date & Time: 08 July 2006, 15:00
"Event Location: Hickory, NC
"Event Type: Stolen Portable Nuclear Gauge
"Notifications: The following organizations have been notified, the FBI, the N.C Highway Patrol, Iredale County Sheriff, N.C. Division of Emergency Management.
"Event Description: N.C. Radiation Protection Section was notified on 08 July 2006 by the designee RSO for APAC Atlantic, Inc Asheville Division / Hickory Branch of the theft of a Troxler Electronics Model 4640 B portable moisture density gauge (Serial No. 765). The gauge contained one sealed source: Cesium-137, 9 millicuries.
"The device was stored in a locked steel transport box attached to the bed of a White 2006 Dodge Dakota, license plate no. VV2525, with 'APAC' signage on the doors. In addition to being locked in the steel over-pack, the gauge is locked in the required transportation container and the operating mechanism is locked. However, keys to all three locks are in the truck. The truck was stolen in the early morning hours from the licensee's gated and locked facility.
"The Radiation Protection Section is working with the licensee and local law enforcement to recover the gauge.
"Media Attention: N.C. Radiation Protection has not received any media attention as of this report. A potential news release is pending."
NC Incident No. 06-20.
* * * UPDATE AT 0415 ON 07/10/06 FROM LEE COX TO W. GOTT * * *
In the evening of 07/09/06 the abandoned gauge was found undamaged and in its case in a parking lot in Hickory NC. The source rod was still locked in the stowed position.
Notified R1DO (P. Henderson), NMSS EO (Brach) and emailed to ILTAB.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.
The following information was received via fax:
"Licensee: APAC Atlantic, Inc, Asheville Division / Hickory Branch
"Event Date &Time: 08 July 2006 between 02:00 and 05:00 am
"Report Date & Time: 08 July 2006, 15:00
"Event Location: Hickory, NC
"Event Type: Stolen Portable Nuclear Gauge
"Notifications: The following organizations have been notified, the FBI, the N.C Highway Patrol, Iredale County Sheriff, N.C. Division of Emergency Management.
"Event Description: N.C. Radiation Protection Section was notified on 08 July 2006 by the designee RSO for APAC Atlantic, Inc Asheville Division / Hickory Branch of the theft of a Troxler Electronics Model 4640 B portable moisture density gauge (Serial No. 765). The gauge contained one sealed source: Cesium-137, 9 millicuries.
"The device was stored in a locked steel transport box attached to the bed of a White 2006 Dodge Dakota, license plate no. VV2525, with 'APAC' signage on the doors. In addition to being locked in the steel over-pack, the gauge is locked in the required transportation container and the operating mechanism is locked. However, keys to all three locks are in the truck. The truck was stolen in the early morning hours from the licensee's gated and locked facility.
"The Radiation Protection Section is working with the licensee and local law enforcement to recover the gauge.
"Media Attention: N.C. Radiation Protection has not received any media attention as of this report. A potential news release is pending."
NC Incident No. 06-20.
* * * UPDATE AT 0415 ON 07/10/06 FROM LEE COX TO W. GOTT * * *
In the evening of 07/09/06 the abandoned gauge was found undamaged and in its case in a parking lot in Hickory NC. The source rod was still locked in the stowed position.
Notified R1DO (P. Henderson), NMSS EO (Brach) and emailed to ILTAB.
THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL
Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.