Event Notification Report for June 06, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/05/2006 - 06/06/2006

EVENT NUMBERS
426214262245095

Power Reactor
Event Number: 42621
Facility: CALLAWAY
Region: 4     State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: GARY OLMSTEAD
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 06/06/2006
Notification Time: 19:40 [ET]
Event Date: 06/06/2006
Event Time: 13:39 [CDT]
Last Update Date: 06/06/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
MIKE RUNYAN (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF "A" TRAIN OF OFFSITE VITAL POWER DUE TO RELAY TESTING

"Callaway plant was in mode 1 at 100 percent power. Work was in progress on calibrating lockout devices on the B switchyard buss. At approximately 1339 CDT during performance of this work, Callaway plant experienced a loss of switchyard buss B. This resulted in loss of A train offsite power, load shed on A train vital 4160 volt buss (NB01), shutdown sequencer actuation for buss NBO1, start on the A train emergency diesel generator, turbine driven auxiliary feedwater pump actuations, [and] steam generator blowdown and sample isolations. B train offsite vital power and both emergency diesel generators were available. These actuations were consistent with loss of 1 vital AC train. Emergency systems responded as expected.

"As of 1630 CDT, the plant is at 100 percent power. Power has been restored to the B switchyard buss. The normal offsite supply to bus NBO1 has been restored and the diesel generator secured. Determination of the cause of the lockout device actuation is in progress."

The licensee notified the NRC Resident Inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 42622
Facility: FERMI
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: MIKE HIMEBAUCH
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 06/06/2006
Notification Time: 23:09 [ET]
Event Date: 06/06/2006
Event Time: 16:00 [EDT]
Last Update Date: 06/15/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(v)(D) - ACCIDENT MITIGATION
Person (Organization):
MONTE PHILLIPS (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
FAILURE TO MEET EMERGENCY EQUIPMENT SERVICE WATER SURVEILLANCE REQUIREMENT

"On June 6, 2006 at 1600 EDT the Division 2 Emergency Equipment Service Water System (EESW) was in service for a planned surveillance test when the system failed to achieve required flows as specified in the surveillance. These flow rates are acceptance criteria and therefore resulted in system inoperability. EESW cools the Emergency Equipment Cooling Water (EECW) System which in turn cools various safety related components including the High Pressure Coolant Injection (HPCI) System Area Cooler. Unplanned HPCI inoperability occurred due to the Division 2 EECW/EESW inoperability based on loss of the HPCI System Area Cooler. A 14 day Limiting Condition for Operation (LCO) was entered for HPCI per LCO 3.5.1. This report is being made pursuant to 10CFR50.72(b)(3)(v)(D) as a condition that at the time of discovery could have prevented the fulfillment of a safety function needed to mitigate the consequences of an accident, based on loss of a single train safety system."

The licensee notified the NRC Resident Inspector.

* * * RETRACTION AT 08:14 ON 6/15/2006 FROM JEFF GROFF TO ABRAMOVITZ * * *

"On June 6, 2006 at 1600 EDT, during the performance of the quarterly pump and valve operability surveillance test on Division 2 of the Emergency Equipment Service Water System (EESW), the minimum pump flow required by the procedure to perform the test could not be established. Because minimum pump flow could not be established, Division 2 of EESW was declared inoperable. EESW cools the Emergency Equipment Cooling Water (EECW) System which in turn cools various safety related components including the High Pressure Coolant Injection (HPCI) System Area Cooler. HPCI was declared inoperable based on loss of the HPCI System Area Cooler due to the Division 2 EECW/EESW inoperability. A 14 day Limiting Condition for Operation (LCO) was entered for HPCI per LCO 3.5.1. A report was made to the NRC pursuant to 10CFR50.72(b)(3)(v)(D) as a condition that at the time of discovery could have prevented the fulfillment of a safety function needed to mitigate the consequences of an accident, based on loss of a single train safety system.

"On June 7, 2006, the test was re-performed with the valve in the bypass line around the heat exchanger Temperature Control Valve (TCV) throttled open. The required pump flow was established and the surveillance was successfully completed at 1815 EDT.

"Further Engineering evaluation concluded that minimum pump flow could not be established on June 6, 2006 due to normal pump wear and heat exchanger fouling. The pump flow required for performing the pump and valve operability surveillance test was established to monitor pump degradation and is higher than the flow required for the EESW system to perform its safety function. It has been verified that the measured flow exceeds the system design basis required flow with an adequate margin and that the pump and heat exchanger remain adequate to support the HPCI room cooling operation. The HPCI safety function was maintained throughout this period; therefore, this event is being retracted."

The licensee notified the NRC Resident Inspector. Notified the R3DO (Louden).


General Information or Other
Event Number: 45095
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: ANVIL CORPORATION
Region: 4
City: BELLINGHAM   State: WA
County:
License #: WN-IR031-1
Agreement: Y
Docket:
NRC Notified By: ARDEN SCROGGS
HQ OPS Officer: DONALD NORWOOD
Notification Date: 05/26/2009
Notification Time: 14:59 [ET]
Event Date: 06/06/2006
Event Time: 00:00 [PDT]
Last Update Date: 05/26/2009
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MICHAEL SHANNON (R4DO)
MARK THAGGARD (FSME)
Event Text
AGREEMENT STATE REPORT - DROPPED RADIOGRAPHY DEVICE

The following was received from the State of Washington via e-mail regarding a previously unreported event:

"This is notification of an event in Washington State as reported to or investigated by the WA Department of Health, Office of Radiation Protection.

"A radiography crew was attempting to hoist a Co-60 radiography device to an elevated platform to perform work at an oil refinery. During the process of hoisting the device it slipped out of its rigging and fell an estimated 23 feet to the pavement below. No associated equipment was connected to the device and the plugs were still inserted. The metal flange on the device was dented but there was no other obvious damage. The device is an AEA model 741B, serial number B100. It contained a 5.5 Curie Co-60 Model 424-18 AEA source, serial number 2418.

"A radiation survey was performed by the radiography companies' crew and later by the RSO. The readings were normal for that device. A control cable was attached to the source inside the device and the source was rotated. It was determined to move freely and not bound in the shielded position within the device. Operations with this device were terminated and the device was sent back to its licensed storage location in Burlington, Washington. The radiography company sent the device back to QSA Global for evaluation and maintenance.

"The licensee's RSO stated that repairs were made to a bracket and the handle was replaced. The maintenance was performed. The device was resourced and relabeled and returned to the licensee.

"This incident, given [Washington state] report number WA-06-043 is closed. There was no release of activity. Personnel exposure was kept low so that no exposure limits were exceeded."