Event Notification Report for April 29, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
04/28/2006 - 04/29/2006
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 42536
Facility: COOK
Region: 3 State: MI
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BUD HINCKLEY
HQ OPS Officer: JOHN MacKINNON
Region: 3 State: MI
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BUD HINCKLEY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 04/29/2006
Notification Time: 14:19 [ET]
Event Date: 04/29/2006
Event Time: 10:56 [EDT]
Last Update Date: 04/30/2006
Notification Time: 14:19 [ET]
Event Date: 04/29/2006
Event Time: 10:56 [EDT]
Last Update Date: 04/30/2006
Emergency Class: UNUSUAL EVENT
10 CFR Section:
10 CFR Section:
Person (Organization):
HIRONORI PETERSON (R3)
MARY JANE ROSS-LEE (NRR)
PETER WILSON (IRD)
BOZZO (DHS)
DUNKER (FEMA)
HIRONORI PETERSON (R3)
MARY JANE ROSS-LEE (NRR)
PETER WILSON (IRD)
BOZZO (DHS)
DUNKER (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown |
DISCOVERY OF AFTER-THE- FACT EMERGENCY CONDITION - UNUSUAL EVENT DUE TO RCS LINEUP
"D.C. Cook Unit 2 was in Mode 4 and heating up after Unit 2 Cycle 16 refueling outage when 2-IMO-340 (East RHR pump to Charging Pump Suction Header) was throttled open. RHR suction was aligned to Loop 2 Hot Leg with wide range RCS pressure at 337 psig and RCS average temperature 280 degrees Fahrenheit. Charging header safety valve 2-SV-56 lifted with a setting of 220 psig and relieved to the Pressurizer Relief Tank (PRT) between 10:56:00 and 10:58:30. 2-IMO-340 was then closed. Approximately, 120 gallons of reactor coolant were directed to the PRT during the approximate 2.5 minutes, resulting in a flow rate of approximately 48 gpm, greater than the 25 gallon per minute identified leak rate limit for an Unusual Event [10 CFR 50.72(a)(1)(i)]. Time of discovery for leakage quantity and reportability was 13:21 on 4/29/06.
"Therefore, for approximately 2.5 minutes, D.C. Cook Unit 2 met the conditions for an Unusual Event. However, this fact was discovered after leakage was stopped. Unit 2 is stable in Mode 4 at 340 degrees Fahrenheit and 405 psig RCS pressure.
"An Unusual Event was NOT declared, but the conditions for an Unusual Event were met under Emergency Condition Criteria S-8 between 10:56:00 and 10:58:30 on 4/29/06. This ENS notification is being made within one hour of the discovery of the undeclared event."
The licensee will notify the NRC Resident Inspector.
* * * RETRACTION ON 4/30/06 AT 1419 EDT FROM D. TURINETTI TO J. MACKINNON * * *
"EN# 42536 reported that D.C. Cook Unit 2 satisfied the conditions for entry into an Unusual Event under Emergency Condition Criteria S-B, identified RCS leakage exceeding 25 GPM. This was identified after system alignment had been restored, ending the event, and was reported as an after the fact declaration that the conditions for an Unusual Event had been satisfied, but not declared. Subsequent review of this event has determined that the conditions for Emergency Condition Criteria S-B were not satisfied in that no identified RCS leakage occurred during this event. The diversion of 120 gallons of CVCS [Chemical Volume and Control System] inventory was the result of plant alignment by Operations personnel which was immediately recognized and terminated. Plant systems and components functioned as designed to terminate this event."
The licensee will notify the NRC Resident Inspector. Notified R3DO (H. Peterson).
"D.C. Cook Unit 2 was in Mode 4 and heating up after Unit 2 Cycle 16 refueling outage when 2-IMO-340 (East RHR pump to Charging Pump Suction Header) was throttled open. RHR suction was aligned to Loop 2 Hot Leg with wide range RCS pressure at 337 psig and RCS average temperature 280 degrees Fahrenheit. Charging header safety valve 2-SV-56 lifted with a setting of 220 psig and relieved to the Pressurizer Relief Tank (PRT) between 10:56:00 and 10:58:30. 2-IMO-340 was then closed. Approximately, 120 gallons of reactor coolant were directed to the PRT during the approximate 2.5 minutes, resulting in a flow rate of approximately 48 gpm, greater than the 25 gallon per minute identified leak rate limit for an Unusual Event [10 CFR 50.72(a)(1)(i)]. Time of discovery for leakage quantity and reportability was 13:21 on 4/29/06.
"Therefore, for approximately 2.5 minutes, D.C. Cook Unit 2 met the conditions for an Unusual Event. However, this fact was discovered after leakage was stopped. Unit 2 is stable in Mode 4 at 340 degrees Fahrenheit and 405 psig RCS pressure.
"An Unusual Event was NOT declared, but the conditions for an Unusual Event were met under Emergency Condition Criteria S-8 between 10:56:00 and 10:58:30 on 4/29/06. This ENS notification is being made within one hour of the discovery of the undeclared event."
The licensee will notify the NRC Resident Inspector.
* * * RETRACTION ON 4/30/06 AT 1419 EDT FROM D. TURINETTI TO J. MACKINNON * * *
"EN# 42536 reported that D.C. Cook Unit 2 satisfied the conditions for entry into an Unusual Event under Emergency Condition Criteria S-B, identified RCS leakage exceeding 25 GPM. This was identified after system alignment had been restored, ending the event, and was reported as an after the fact declaration that the conditions for an Unusual Event had been satisfied, but not declared. Subsequent review of this event has determined that the conditions for Emergency Condition Criteria S-B were not satisfied in that no identified RCS leakage occurred during this event. The diversion of 120 gallons of CVCS [Chemical Volume and Control System] inventory was the result of plant alignment by Operations personnel which was immediately recognized and terminated. Plant systems and components functioned as designed to terminate this event."
The licensee will notify the NRC Resident Inspector. Notified R3DO (H. Peterson).
General Information or Other
Event Number: 42538
Rep Org: OHIO BUREAU OF RADIATION PROTECTION
Licensee: WEAVER BOOS CONSULTANTS, LLC
Region: 3
City: PORT CLINTON State: OH
County: OTTAWA
License #:
Agreement: Y
Docket:
NRC Notified By: STEVE HELMER
HQ OPS Officer: BILL HUFFMAN
Licensee: WEAVER BOOS CONSULTANTS, LLC
Region: 3
City: PORT CLINTON State: OH
County: OTTAWA
License #:
Agreement: Y
Docket:
NRC Notified By: STEVE HELMER
HQ OPS Officer: BILL HUFFMAN
Notification Date: 05/01/2006
Notification Time: 08:31 [ET]
Event Date: 04/29/2006
Event Time: 00:00 [EDT]
Last Update Date: 05/01/2006
Notification Time: 08:31 [ET]
Event Date: 04/29/2006
Event Time: 00:00 [EDT]
Last Update Date: 05/01/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
HIRONORI PETERSON (R3)
GREG MORELL (NMSS)
HIRONORI PETERSON (R3)
GREG MORELL (NMSS)
AGREEMENT STATE - DAMAGED MOISTURE DENSITY GAUGE
A representative of the State of Ohio Bureau of Radiation Protection reported an incident resulting in a damaged moisture density gauge. A moisture density gauge was run over by a truck at the Port Clinton, Ohio landfill when the State licensee was setting up to use the gauge. The top of the gauge was smashed and the fire department and a consultant for the licensee responded to the scene. There was no indication of contamination or damage to the sources. The gauge was placed back into its container and locked up at the landfill at a secure location. The State is sending inspectors out today to assess the incident and licensee actions. The licensee plans to ship the gauge to a repair facility.
The State did not have the make or model of the gauge or source serial numbers at the time this event was reported. The licensee number of the licensee was given as Ohio license 31210-2500-5000.
A representative of the State of Ohio Bureau of Radiation Protection reported an incident resulting in a damaged moisture density gauge. A moisture density gauge was run over by a truck at the Port Clinton, Ohio landfill when the State licensee was setting up to use the gauge. The top of the gauge was smashed and the fire department and a consultant for the licensee responded to the scene. There was no indication of contamination or damage to the sources. The gauge was placed back into its container and locked up at the landfill at a secure location. The State is sending inspectors out today to assess the incident and licensee actions. The licensee plans to ship the gauge to a repair facility.
The State did not have the make or model of the gauge or source serial numbers at the time this event was reported. The licensee number of the licensee was given as Ohio license 31210-2500-5000.