Skip to main content

Event Notification Report for April 23, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/22/2006 - 04/23/2006

EVENT NUMBERS
4252242520

General Information or Other
Event Number: 42522
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: DRASH CONSULTING ENGINEERS
Region: 4
City: SAN ANTONIO   State: TX
County:
License #: L04724
Agreement: Y
Docket:
NRC Notified By: SONIA SIMMONS
HQ OPS Officer: BILL GOTT
Notification Date: 04/24/2006
Notification Time: 10:42 [ET]
Event Date: 04/23/2006
Event Time: 07:30 [CDT]
Last Update Date: 05/05/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
THOMAS FARNHOLTZ (R4)
GREG MORELL (NMSS)
ILTAB (email)
Mexico (email)
Event Text
AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE

A Troxler Moisture Density Gauge (sn 25459; 40 millicuries Am-241/Be and 8 millicuries Cs-137) was stolen from the operator's truck which was parked at his home. This was reported to the police and a reward was offered.

Texas Incident No.: I-8327

* * * UPDATE FROM S. SIMMONS TO P. SNYDER ON 05/02/06 AT 1315 * * *

This update was inadvertently entered as EN 42544 on 05/02/06. EN 42544 has been deleted.

The following information was received from the state via e-mail:

"On Saturday, April 22, 2006, a technician for Drash Consulting Engineers, Inc., was working a full time project performing density testing services. He stated that upon completion of the work day he felt very sleepy and was worried he might fall asleep at the wheel while driving. He had worked a lot of hours that week (70 hrs). He went home for a shower and a nap before returning the gauge to secured storage. [He] locked the gauge in the cab of the pickup truck with its transport case chained to the steering wheel. He did not lock the transport case. He awoke the next morning, Sunday, April 23, 2006, around 7:30 am and discovered that the side window of his truck was broken and the case that contained the Troxler Gauge Model 3440, was opened and the gauge was stolen.

"Root Cause: Technician failed to secure the gauge in the most restrictive fashion possible.

"Conclusion: The technician failed to follow company policy that the gauge must be returned to secured storage.

"Licensee corrective actions: The technician was given a one day suspension without pay, a written reprimand, and additional training. On April 25, 2006 a Hazardous Materials Transportation handout ( 49 CFR, Part 172, and Subpart H) was given to all gauge users, that included specific discussion on theft of gauges. DCE supervisory staff will closely monitor technicians working long hours to be sure that gauges are being returned to storage in accordance with company policy.

"Sealed source, device, etc, (make, model #, serial #): Troxler Moisture Density Gauge Model No. 3440, Serial No. 25459, with Am-241 (40 mCi) and Cs-137 (8 mCi) sources.

"Texas Incident No.: I- 8327." The state is following up with the licensee.

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


General Information or Other
Event Number: 42520
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: A SQUARED GROUP; METRIC ENGINEERING
Region: 1
City: MIAMI   State: FL
County:
License #: 3727-2
Agreement: Y
Docket:
NRC Notified By: CHARLES E. ADAMS
HQ OPS Officer: PETE SNYDER
Notification Date: 04/23/2006
Notification Time: 11:59 [ET]
Event Date: 04/23/2006
Event Time: 11:25 [EDT]
Last Update Date: 04/23/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
DANIEL HOLODY (R1)
GARY JANOSKO (NMSS)
ILTAB (e-mail)
Event Text
AGREEMENT STATE REPORT - LOST MOISTURE DENSITY GAUGES RECOVERED

The following was received from the state via email:

"The duty officer was notified 1125 this morning of the theft and apparent recovery of two soil moisture density gauges in Miami, Fl at about 4 am this morning. Thieves broke into a locked Conex at a FL DOT job location on SR 826 between Bird & Flagler. They broke into the locked cabinet in which the gauges were stored. They then broke into the locked transportation boxes and took two gauges belonging to two licensees.

"The first licensee is A Squared Group, license # 3727-2. Gauge was a CPN model MC-3, SN 350808026, Cs-137/AmBe sources 10/50 millicuries.

"The second licensee is Metric Engineering, license # 1704-1. Gauge was a Troxler model 3440, SN 37243, Cs-137/AmBe sources 10/40 millicuries.

"Miami-Dade PD apprehended the thieves as they were departing the storage site. The licensees believe the gauges are in the vehicle which has been impounded by Miami-Dade PD. They are trying to get access to the car to confirm that the gauges are there, but the PD has denied them access to this point. Licensees will call when they have confirmed the gauges are in the car and when they have been returned to their possession. Licensees will also submit a written report on this occurrence.

"Florida continues to investigate this incident."

* * * UPDATE FROM ADAMS TO SNYDER AT 1358 ON 4/23/06 * * *

The following was received from the state via email:

"Both licensees have possession of their gauges. They appear undamaged. The gauges will be leak tested and checked for functionality."

Notified R1DO (Holody) and NMSS EO (Janosko).

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.