Skip to main content

Event Notification Report for April 14, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/13/2006 - 04/14/2006

EVENT NUMBERS
425044250042502

Power Reactor
Event Number: 42504
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [1] [] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: DOUG SMITH
HQ OPS Officer: BILL GOTT
Notification Date: 04/14/2006
Notification Time: 16:07 [ET]
Event Date: 04/14/2006
Event Time: 14:25 [CDT]
Last Update Date: 04/14/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL 50.72(b)(3)(iv)(A) - VALID SPECIF SYS ACTUATION
Person (Organization):
THOMAS KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R Y 100 Power Operation 0 Hot Standby
Event Text
MANUAL REACTOR TRIP DUE TO CONDENSATE PUMP AND FEEDWATER PUMP TRIP

"At 1425 on April 14, 2006, a lockout trip of 11 Condensate Pump occurred. The condensate pump trip caused an expected lockout trip of 11 Main Feedwater Pump trip. With the loss of 50% of feedwater pump capacity, the Shift Supervisor directed a manual Unit 1 reactor trip. The manual reactor trip was successful and all systems responded as expected. The reactor protection system actuation is reportable under 10CFR 50.72(b)(2). A reactor trip from full power results in an expected steam generator narrow range level shrink to 0%. This resultant narrow range steam generator level caused an expected Auxiliary Feedwater System Actuation. Both 11 and 12 Auxiliary Feedwater Pumps started as expected. Auxiliary feedwater actuation is reportable under10CFR 50.72(b)(3).

"Investigation is underway to determine the cause of 11 Condensate Pump lockout.

"Plant operations are underway per emergency procedure 1ES-0.1, Reactor Trip Recovery, and 1C1.3, Unit 1 Shutdown, to stabilize the plant in Mode 3, Hot Standby."

All control rods fully inserted. Steam generators are discharging steam to the condenser steam dump system. The Auxiliary Feedwater Pumps are maintaining Steam Generator level. The electrical grid is stable.

The licensee will notify the NRC Resident Inspector.


General Information or Other
Event Number: 42500
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: TEXAS INSTRUMENTS, INC
Region: 4
City: DALLAS   State: TX
County:
License #: 585-D-103-G
Agreement: Y
Docket:
NRC Notified By: RAY JISHA
HQ OPS Officer: BILL HUFFMAN
Notification Date: 04/14/2006
Notification Time: 10:10 [ET]
Event Date: 04/14/2006
Event Time: 00:00 [CDT]
Last Update Date: 04/14/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
TROY PRUETT (R4)
GREG MORELL (NMSS)
Event Text
AGREEMENT STATE - TWO TRITIUM EXIT SIGNS LOST

The State provided the following information via email:

"Event type: Lost, two self-luminous, 20 Ci/ea., H-3, exit signs were discovered missing, presumed discarded.

"Event description:
The manufacturer is SRB Technologies (Canada), Inc.

1) Model: BetaLux-E/Luminexit, SN 272697, Activity: 20 Ci;

2) Model: BetaLux-E/Luminexit, SN 270605, Activity: 20 Ci.

"One sign was noted as being discarded by the housekeeping staff and a subsequent inventory investigation showed that another sign was missing from an area that was renovated in August of last year."

Texas Incident No.: I- 8325

THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.

This source is not amongst those sources or devices identified by the IAEA Code of Conduct for the Safety & Security of Radioactive Sources to be of concern from a radiological standpoint. Therefore is it being categorized as a less than Category 3 source


Fuel Cycle Facility
Event Number: 42502
Facility: NUCLEAR FUEL SERVICES INC.
Region: 2     State: TN
Unit: [] [] []
RX Type: URANIUM FUEL FABRICATION
Comments: HEU CONVERSION & SCRAP RECOVERY
NAVAL REACTOR FUEL CYCLE
LEU SCRAP RECOVERY
NRC Notified By: DAVID HENSON
HQ OPS Officer: MARK ABRAMOVITZ
Notification Date: 04/14/2006
Notification Time: 15:32 [ET]
Event Date: 04/14/2006
Event Time: 15:32 [EDT]
Last Update Date: 05/11/2008
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
ROBERT HAAG (R2)
TOM ESSIG (NMSS)
Event Text
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
THIS IS NOT A NEW REPORT.

This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
FAILURE OF A FITNESS FOR DUTY TEST

A non-licensed employee supervisor had a confirmed positive for illegal drugs during a random fitness-for-duty test. The employees access to the plant has been terminated. Contact the Headquarters Operations Officer for additional details.

The licensee will notify the NRC Resident Inspector.

* * * UPDATE ON 05/11/08 BY H. Crouch * * *

THIS IS NOT A NEW REPORT.

This event report was originally withheld from public release under the NRC's policy for protecting sensitive unclassified information. The NRC has reevaluated this policy and is now making this event report available to the public with suitable redactions.
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *