Event Notification Report for March 27, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/26/2006 - 03/27/2006
EVENT NUMBERS
42448
Other Nuclear Material
Event Number: 42448
Rep Org: NATIONAL INST OF STANDARDS & TECH
Licensee: NATIONAL INST OF STANDARDS & TECH
Region: 1
City: GAITHERSBURG State: MD
County:
License #: SNM-362
Agreement: Y
Docket:
NRC Notified By: TIM MENGERS
HQ OPS Officer: MIKE RIPLEY
Licensee: NATIONAL INST OF STANDARDS & TECH
Region: 1
City: GAITHERSBURG State: MD
County:
License #: SNM-362
Agreement: Y
Docket:
NRC Notified By: TIM MENGERS
HQ OPS Officer: MIKE RIPLEY
Notification Date: 03/28/2006
Notification Time: 09:36 [ET]
Event Date: 03/27/2006
Event Time: 09:30 [EST]
Last Update Date: 04/05/2006
Notification Time: 09:36 [ET]
Event Date: 03/27/2006
Event Time: 09:30 [EST]
Last Update Date: 04/05/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
36.83(a)(5) - INOP ACCESS CTRL SYS 36.83(a)(1) - UNSHIELD STUCK SOURCE
10 CFR Section:
36.83(a)(5) - INOP ACCESS CTRL SYS 36.83(a)(1) - UNSHIELD STUCK SOURCE
Person (Organization):
WILLIAM COOK (R1)
GREG MORELL (NMSS)
WILLIAM COOK (R1)
GREG MORELL (NMSS)
IRRADIATOR SHUTTER FAILS TO CLOSE
The air-actuated shutter mechanism on one of the facility's irradiators (Neutron Products S/N T1497 with 13,500 Curies Co-60) failed to re-close. The irradiator source remained in its shield. A staff scientist entered the irradiator room and isolated the air supply to the shutter allowing the shutter to close. The scientist received less than 2 mrem during the incident. The cause of the shutter failure is being investigated.
* * * UPDATED AT 1103 EDT ON 4/5/06 FROM TIMOTHY MENGERS TO S. SANDIN (via email) * * *
The licensee identified two (2) additional reporting requirements, i.e., 10CFR36.83(a)(1) and 10CFR30.50(c)(1) [Preparation and Submission of Reports], and provided a chronology of the incident. Contact the Headquarters Operations Officer for additional details. Notified R1DO (Finney) and NMSS (Essig).
The air-actuated shutter mechanism on one of the facility's irradiators (Neutron Products S/N T1497 with 13,500 Curies Co-60) failed to re-close. The irradiator source remained in its shield. A staff scientist entered the irradiator room and isolated the air supply to the shutter allowing the shutter to close. The scientist received less than 2 mrem during the incident. The cause of the shutter failure is being investigated.
* * * UPDATED AT 1103 EDT ON 4/5/06 FROM TIMOTHY MENGERS TO S. SANDIN (via email) * * *
The licensee identified two (2) additional reporting requirements, i.e., 10CFR36.83(a)(1) and 10CFR30.50(c)(1) [Preparation and Submission of Reports], and provided a chronology of the incident. Contact the Headquarters Operations Officer for additional details. Notified R1DO (Finney) and NMSS (Essig).