Event Notification Report for March 20, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/19/2006 - 03/20/2006

EVENT NUMBERS
424304243142432424334243442435

Power Reactor
Event Number: 42430
Facility: CLINTON
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: PAT RYAN
HQ OPS Officer: JOHN KNOKE
Notification Date: 03/20/2006
Notification Time: 08:28 [ET]
Event Date: 03/20/2006
Event Time: 04:53 [CST]
Last Update Date: 03/20/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(B) - RPS ACTUATION - CRITICAL
Person (Organization):
DAVE PASSEHL (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 96 Power Operation 0 Hot Shutdown
Event Text
MAIN TURBINE TRIP CAUSED REACTOR SCRAM

"At 0453 CST on March 20, 2006, a main turbine trip occurred resulting in a reactor scram. All control rods fully inserted on the scram signal. All systems performed as expected. Reactor water level is being controlled in the normal operating band and reactor pressure is being controlled at 600 psig.

"The cause of the turbine trip is under investigation. There is no indication that the turbine trip was caused by an actual parameter reaching a trip setpoint. A turbine Low Vacuum trip alarm is indicated in the Main Control Room and is the current focus of troubleshooting activities. Actual main condenser vacuum is at its normal value."

The site is on off-site power, and the EDG's are available if required. All safety related systems are available if required.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 42431
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: SCOTT COON
HQ OPS Officer: JEFF ROTTON
Notification Date: 03/20/2006
Notification Time: 09:18 [ET]
Event Date: 03/20/2006
Event Time: 07:56 [CST]
Last Update Date: 03/20/2006
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a) (1) (i) - EMERGENCY DECLARED 50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
JEFFREY CLARK (R4)
ERIC BENNER (NRR)
TIM MCGINTY (IRD)
JANNIE EVERETTE (DHS)
CHRIS LIGGETT (FEMA)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 82 Power Operation 82 Power Operation
Event Text
UNUSUAL EVENT DECLARED DUE TO SMALL FIRE INSIDE PROTECTED AREA

Fire inside the Protected Area lasting greater than 10 minutes in an electrical conduit between the Ionic trailer and the Water Treatment Building. Power to the electrical feed through the conduit to the Ionic trailer has been secured. No offsite assistance has been requested. The licensee is verifying the status of the fire after securing the power.

The licensee notified the NRC Resident Inspector and the State and Local authorities.

* * * UPDATE FROM ELDON PLETTNER TO JEFF ROTTON AT 0951 EST ON 03/20/06 * * *

Fire was declared out at 0842 CST. Fire was in the EE transformer supplying the Ionic trailer. Fire was extinguished by opening Breaker 48D. The licensee corporate office will be issuing a press release later today.

The licensee notified the NRC Resident Inspector.

* * * UPDATE FROM ELDON PLETTNER TO JEFF ROTTON AT 0959 EST ON 03/20/06 * * *

Licensee terminated the Unusual Event due to the fire being out and plant returned to normal operation with the exception of the Ionic trailer power.

The licensee notified the NRC Resident Inspector.

Notified R4DO (Clark), NRR EO (Benner), IRD Manager (McGinty), DHS (Everette) and FEMA (Liggett)


Power Reactor
Event Number: 42432
Facility: SUMMER
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: DAN GOLDSTON
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/20/2006
Notification Time: 12:53 [ET]
Event Date: 03/20/2006
Event Time: 09:00 [EST]
Last Update Date: 03/20/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
MIKE ERNSTES (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION TO SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL (DHEC) OF SEWAGE SPILL

The licensee reported that an onsite underground line to the sanitary sewage pond broke resulting in back drainage from the pond into the environment of an estimated 60,000 to 70,000 gallons of sewage. The pond sewage has gone into the yard drains and possibly some of the nearby creeks.

The licensee provided the following information via facsimile:

"Approximately 0800 received first notification of discharge from Sanitary Aeration Pond, outfall # 005. At 0825 an initial notification was made to DHEC. Temporary covers were installed over the yard drains. These covers seem to be holding the remnants of the fluid. At 0900 the control room was notified the discharge had made it to the yard drains and thus to the environment. At 1240 the estimate of discharge was revised to 60,000 to 70,000 gallons, which made this potentially newsworthy.

"Suspected cause is a broken underground pipe. No impact on plant operation.

"The discharge was not radioactive."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 42433
Facility: PILGRIM
Region: 1     State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: MICHAEL McDONNELL
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/20/2006
Notification Time: 15:01 [ET]
Event Date: 03/20/2006
Event Time: 10:25 [EST]
Last Update Date: 03/20/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
HAROLD GRAY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FITNESS FOR DUTY - CONFIRMED POSITIVE FOR NON-LICENSED SUPERVISOR DURING RANDOM TEST

"This report is being made in accordance with 10 CFR 26.73 due to a supervisor testing positive during a random fitness for duty test. The employee was fitness for duty tested on 3/16/06. The Medical Review Officer confirmed a positive test at 10:25 EST on 3/20/06. A review of previous work is being performed. The employee's access to the plant has been denied.

"The NRC Resident Inspector has been notified."


Power Reactor
Event Number: 42434
Facility: VOGTLE
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: THOMAS PETRAK
HQ OPS Officer: BILL HUFFMAN
Notification Date: 03/20/2006
Notification Time: 15:51 [ET]
Event Date: 03/20/2006
Event Time: 13:00 [EST]
Last Update Date: 03/20/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - PLANT S/D REQD BY TS
Person (Organization):
MIKE ERNSTES (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 50 Power Operation
Event Text
PLANT SHUTDOWN DUE TO RCS PRESSURE BOUNDARY LEAKAGE

"At 03:56 on 03/20/2006 an intermediate radiation alarm was received on Containment Atmosphere Particulate Radiation Monitor, 2RE-2562A. A review of other containment parameters, such as containment pressure, moisture, temperature, sump levels and other containment radiation monitors were all stable. Chemistry was notified of the increasing particulate radiation levels in containment and immediately pulled the filter paper from radiation monitor 2RE-2562A. A gross count of the filter paper revealed the presence of Na-24 and Co-58. The presence of these two isotopes indicated the possibility of an active RCS leak. An RCS leakrate measurement was initiated. The results of the leakrate measurement showed no measurable change in leakrate. The total leakrate was calculated to be 0.13 gpm.

"At 06:03 on 03/20/2006 a high radiation alarm was received on Containment Atmosphere Particulate Radiation Monitor, 2RE-2562A. Preparations were begun to make a containment entry to walkdown outside the bio-shield and to take a robot, equipped with a camera, to inspect inside the bio-shield.

"At 13:00 personnel from the Unit 2 containment reported that a leak was visible from inside the bio-shield in the area of RCS Loop #1. Based on reports from personnel in containment, the leakage in containment was determined to be pressure boundary leakage and Tech Spec 3.4.13, "RCS Operational LEAKAGE," was entered. As required by TS 3.4.13, at 13:52 on 03/20/2006 a unit shutdown to Mode 3 was initiated to allow further investigations and repair of the leak inside containment. Abnormal Operating Procedure 18004-C, "RCS Leakage" was also entered at this time due to increasing radiation levels on, radiation monitor 2RE-2562A. Per Tech Spec 3.4.13, Mode 3 entry [is] required by no later than 19:00 on 3/20/2006 and Mode 5 entry no later than 01:00 on 3/22/2006."

The Unit shutdown is currently in progress. This is the third shutdown at the Unit for a leak in this vicinity. See similar event reports #42309 dated February 3, 2006, and #42194 dated December 9, 2005.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 42435
Facility: POINT BEACH
Region: 3     State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: RICK ROBBINS
HQ OPS Officer: PETE SNYDER
Notification Date: 03/20/2006
Notification Time: 21:36 [ET]
Event Date: 03/20/2006
Event Time: 17:11 [CST]
Last Update Date: 03/20/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(xi) - OFFSITE NOTIFICATION
Person (Organization):
LAURA KOZAK (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
OIL SPILL ONSITE

"A notification was made to the Wisconsin Department of Natural Resources Spill Response Center by We Energies at 1711 hours on 03/20/06 for a small lube oil spill that occurred on 3/19/06. The spill was initially believed to be very small (less than 5 gallons) and there was no evidence of a release to Lake Michigan. Following a maintenance inspection of the water treatment deaerator vacuum pump, it was conservatively assumed that a maximum quantity of 25 gallons of oil could have been spilled.

"The NRC resident inspector has been notified of this event."