Skip to main content

Event Notification Report for March 16, 2006

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/15/2006 - 03/16/2006

EVENT NUMBERS
4247342425

Other Nuclear Material
Event Number: 42473
Rep Org: MICHIGAN TECHNOLOGICAL UNIVERSITY
Licensee: MICHIGAN TECHNOLOGICAL UNIVERSITY
Region: 3
City: HOUGHTON   State: MI
County:
License #: SNM-256
Agreement: N
Docket:
NRC Notified By: ALLEN NIEMI
HQ OPS Officer: BILL GOTT
Notification Date: 04/05/2006
Notification Time: 11:30 [ET]
Event Date: 03/16/2006
Event Time: 00:00 [EDT]
Last Update Date: 04/05/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
ANNE MARIE STONE (R3)
TOM ESSIG (NMSS)
ILTAB (EMAIL)
CNSC (fax)
Event Text
LOST LICENSED MATERIAL

In 1967 the Michigan Technological University Physics Department obtained 10 Uranium fuel plates. The plates had a triangular shaped tip on the end that measured about 1 inch at the base, 1 inch high and was 0.1 inch thick. On one of the fuel plates, the tip broke off and the Department's RSO maintained the piece in an envelope in the same locked container where he kept the fuel plates. In 1977 during the course of routine laboratory nuclear training work with the fuel plates, one of the students wanted to look at the structure of the piece microscopically for a course in Metallurgy. The RSO gave the student the tip in an envelope sandwiched between 2 copper sheets. The student returned the piece in the envelope, and the envelope was returned to the safe unopened.

On March 16, 2006, the envelope was opened to obtain data on the piece for return to Federal control, and the piece was not in the envelope.

Further investigation determined that the tip was too large to be used in the Scanning Electron Microscope (SEM), and a small piece of the tip was removed. It appears that only this small piece was returned to the RSO. Personnel from the Metallurgy laboratory were questioned and it appears that the tip remained in the Metallurgy facility until after 1991 when it is thought that it was disposed of in the regular trash.

The uranium fuel plates were 20 weight percent enriched Uranium. The tip contained approximately 1.1 grams enriched uranium or 0.21 gm U-235. It had an activity of 0.3 micro curies U-238 and 0.4 micro curies U-235. On contact measurements for the tip are expected to be less than 1 milli rem per hour on contact.

On March 30, 2006, the Director, Occupational Health and Safety conducted a thorough search and survey of the Metallurgy laboratory and could not find the tip.


THIS MATERIAL EVENT CONTAINS A "LESS THAN CAT 3" LEVEL OF RADIOACTIVE MATERIAL

Sources that are "Less than IAEA Category 3 sources," are either sources that are very unlikely to cause permanent injury to individuals or contain a very small amount of radioactive material that would not cause any permanent injury. Some of these sources, such as moisture density gauges or thickness gauges that are Category 4, the amount of unshielded radioactive material, if not safely managed or securely protected, could possibly - although it is unlikely - temporarily injure someone who handled it or were otherwise in contact with it, or who were close to it for a period of many weeks.


Power Reactor
Event Number: 42425
Facility: SAINT LUCIE
Region: 2     State: FL
Unit: [] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: JOHN BRADY
HQ OPS Officer: JOHN KNOKE
Notification Date: 03/17/2006
Notification Time: 01:30 [ET]
Event Date: 03/16/2006
Event Time: 22:50 [EST]
Last Update Date: 03/23/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
MIKE ERNSTES (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF COMMUNICATION - ERDADS COMPUTER FAILED

"On 3/16/2006 at approximately 2010 [EST], the U2 ERDADS computer failed and stopped providing updated plant data to the Unit 2 and Technical Support Center operator consoles, leaving the displays essentially static. Investigation of the failure mode is ongoing and attempts to restore the ERDADS to normal are in progress.

"Loss of the ERDADS output for greater than one hour is reportable as a major loss of assessment and communication capability under 10 CFR 50.72(b)(3)(xiii)."


The licensee notified the NRC Resident Inspector.

* * * UPDATE FROM J. HESSLING TO W. GOTT AT 1603 ON 03/23/06 * * *

ERDADS system is restored.

The licensee notified the NRC Resident Inspector.

Notified R2DO (C. Evans)