Event Notification Report for March 15, 2006
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/14/2006 - 03/15/2006
Power Reactor
Event Number: 42423
Facility: SUSQUEHANNA
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GORDY ROBINSON
HQ OPS Officer: BILL GOTT
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: GORDY ROBINSON
HQ OPS Officer: BILL GOTT
Notification Date: 03/15/2006
Notification Time: 09:41 [ET]
Event Date: 03/15/2006
Event Time: 05:57 [EST]
Last Update Date: 03/18/2006
Notification Time: 09:41 [ET]
Event Date: 03/15/2006
Event Time: 05:57 [EST]
Last Update Date: 03/18/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
10 CFR Section:
50.72(b)(3)(xiii) - LOSS COMM/ASMT/RESPONSE
Person (Organization):
PAUL KROHN (R1)
PAUL KROHN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
LOSS OF ASSESSMENT CAPABILITY - SAFETY PARAMETER DISPLAY SYSTEM
"Unit 1 is currently in Mode 5 for the planned 14th Refuel and Inspection Outage.
"At 05:57 on March 15, 2006 the Unit 1 Safety Parameter Display System (SPDS) was deenergized during planned refuel outage activities. It has been determined that it will not be restored within the required eight hours. Currently, restoration is scheduled for March 17, 2006 at 00:01. All required instrumentation is available in the control room.
"ERDS will remain operable during the work window but several points will not be available. For example 23 of 58 ERDS points will be unavailable while SPDS is out of service. However, the ERDS system will still be operable and transmit the remaining points.
"Loss of Emergency Assessment Capability - A review of the ability of the Emergency organization to function without SPDS was performed. Alternate sources for many of the points in SPDS were identified and are contained on an Emergency Plan format in PICSY (plant integrated computer system). Those points not available from PICSY can be obtained from the control room. With these compensatory actions and the communications in place between the facilities, there will not be a major loss of emergency assessment capability.
"Since the Unit 1 SPDS computer system will be unavailable for greater than 8 hours, this is considered reportable under 10CFR50.72(b)(3)(xiii)."
The licensee notified the NRC Resident Inspector.
* * * UPDATE FROM J. HUFFORD TO J. KNOKE AT 10:41 EST ON 03/18/06 * * *
Licensee has restored the Unit 1 Safety Parameter Display System (SPDS), which was deenergized during planned refuel outage activities for scheduled maintenance.
The licensee notified the NRC Resident Inspector. Notified R1DO (Krohn).
"Unit 1 is currently in Mode 5 for the planned 14th Refuel and Inspection Outage.
"At 05:57 on March 15, 2006 the Unit 1 Safety Parameter Display System (SPDS) was deenergized during planned refuel outage activities. It has been determined that it will not be restored within the required eight hours. Currently, restoration is scheduled for March 17, 2006 at 00:01. All required instrumentation is available in the control room.
"ERDS will remain operable during the work window but several points will not be available. For example 23 of 58 ERDS points will be unavailable while SPDS is out of service. However, the ERDS system will still be operable and transmit the remaining points.
"Loss of Emergency Assessment Capability - A review of the ability of the Emergency organization to function without SPDS was performed. Alternate sources for many of the points in SPDS were identified and are contained on an Emergency Plan format in PICSY (plant integrated computer system). Those points not available from PICSY can be obtained from the control room. With these compensatory actions and the communications in place between the facilities, there will not be a major loss of emergency assessment capability.
"Since the Unit 1 SPDS computer system will be unavailable for greater than 8 hours, this is considered reportable under 10CFR50.72(b)(3)(xiii)."
The licensee notified the NRC Resident Inspector.
* * * UPDATE FROM J. HUFFORD TO J. KNOKE AT 10:41 EST ON 03/18/06 * * *
Licensee has restored the Unit 1 Safety Parameter Display System (SPDS), which was deenergized during planned refuel outage activities for scheduled maintenance.
The licensee notified the NRC Resident Inspector. Notified R1DO (Krohn).
General Information or Other
Event Number: 42628
Rep Org: LOUISIANA RADIATION PROTECTION DIV
Licensee: NATIONAL INSPECTIONS SERVICES
Region: 4
City: LAFAYETTE State: LA
County:
License #: LA-11160-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JOHN MacKINNON
Licensee: NATIONAL INSPECTIONS SERVICES
Region: 4
City: LAFAYETTE State: LA
County:
License #: LA-11160-L01
Agreement: Y
Docket:
NRC Notified By: RICHARD PENROD
HQ OPS Officer: JOHN MacKINNON
Notification Date: 06/08/2006
Notification Time: 18:14 [ET]
Event Date: 03/15/2006
Event Time: 00:00 [CDT]
Last Update Date: 06/08/2006
Notification Time: 18:14 [ET]
Event Date: 03/15/2006
Event Time: 00:00 [CDT]
Last Update Date: 06/08/2006
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
MIKE RUNYAN (R4)
SCOTT MOORE (NMSS)
MIKE RUNYAN (R4)
SCOTT MOORE (NMSS)
LOUISIANA AGREEMENT STATE REPORT - EXCESSIVE EXPOSURE
Louisiana Agreement State Report was faxed to the NRC Operation Center.
"National Inspection Services reported on June 6, 2006 that a trainee, [deleted], received an excessive exposure. The film badge for [deleted] had an exposure of 5.879 Rem for the March 2006 wear period. This individual is no longer working for National Inspection Services. His employment ran from February 23, 2006 to April 26, 2006. The facility is performing an investigation and will report their findings to the Louisiana Department of Environmental Quality. [Deleted], Radiation Safety Officer, stated that the daily pocket dosimeter records do not reflect an excessive exposure."
Event Report ID No.: LA060011
Louisiana Agreement State Report was faxed to the NRC Operation Center.
"National Inspection Services reported on June 6, 2006 that a trainee, [deleted], received an excessive exposure. The film badge for [deleted] had an exposure of 5.879 Rem for the March 2006 wear period. This individual is no longer working for National Inspection Services. His employment ran from February 23, 2006 to April 26, 2006. The facility is performing an investigation and will report their findings to the Louisiana Department of Environmental Quality. [Deleted], Radiation Safety Officer, stated that the daily pocket dosimeter records do not reflect an excessive exposure."
Event Report ID No.: LA060011